Harmonic analysis of 240V AC power supply using TMS320C6713 DSK

Signal harmonics presence in a power system is a major concerned to power engineers for many years. With increasing use of nonlinear loads in power systems, the harmonic pollution becomes more serious. One of the widely used computation algorithm for harmonic analysis is fast Fourier transform (FFT)...

Full description

Saved in:
Bibliographic Details
Main Authors: M., Awan, D., Ismoyo, N., Yahya
Format: Conference or Workshop Item
Published: 2009
Subjects:
Online Access:http://eprints.utp.edu.my/340/1/paper.pdf
http://www.scopus.com/inward/record.url?eid=2-s2.0-70449673244&partnerID=40&md5=252241b3ce924d474a8d187e94949a4a
http://eprints.utp.edu.my/340/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.340
record_format eprints
spelling my.utp.eprints.3402017-01-19T08:25:46Z Harmonic analysis of 240V AC power supply using TMS320C6713 DSK M., Awan D., Ismoyo N., Yahya TK Electrical engineering. Electronics Nuclear engineering Signal harmonics presence in a power system is a major concerned to power engineers for many years. With increasing use of nonlinear loads in power systems, the harmonic pollution becomes more serious. One of the widely used computation algorithm for harmonic analysis is fast Fourier transform (FFT). In this paper, a harmonic analyzer using FFT was implemented on TMS320C6713 DSK. Here, two tests were conducted in order to analyze the harmonic content of 240V, 50Hz power supply. First, the supply voltage is stepped down to 5V using a voltage divider in order to match the power rating of the DSK input. Secondly, the supply voltage is stepped down using a step-down transformer. The output from the DSK was displayed on oscilloscope and Code Composer Studio Software. This work has demonstrated the possibility of analyzing the 240V power supply harmonic content using the DSK board. © 2009 IEEE. 2009 Conference or Workshop Item NonPeerReviewed application/pdf http://eprints.utp.edu.my/340/1/paper.pdf http://www.scopus.com/inward/record.url?eid=2-s2.0-70449673244&partnerID=40&md5=252241b3ce924d474a8d187e94949a4a M., Awan and D., Ismoyo and N., Yahya (2009) Harmonic analysis of 240V AC power supply using TMS320C6713 DSK. In: 2009 International Conference on Signal Processing Systems, ICSPS 2009, 15 May 2009 through 17 May 2009, Singapore. http://eprints.utp.edu.my/340/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
M., Awan
D., Ismoyo
N., Yahya
Harmonic analysis of 240V AC power supply using TMS320C6713 DSK
description Signal harmonics presence in a power system is a major concerned to power engineers for many years. With increasing use of nonlinear loads in power systems, the harmonic pollution becomes more serious. One of the widely used computation algorithm for harmonic analysis is fast Fourier transform (FFT). In this paper, a harmonic analyzer using FFT was implemented on TMS320C6713 DSK. Here, two tests were conducted in order to analyze the harmonic content of 240V, 50Hz power supply. First, the supply voltage is stepped down to 5V using a voltage divider in order to match the power rating of the DSK input. Secondly, the supply voltage is stepped down using a step-down transformer. The output from the DSK was displayed on oscilloscope and Code Composer Studio Software. This work has demonstrated the possibility of analyzing the 240V power supply harmonic content using the DSK board. © 2009 IEEE.
format Conference or Workshop Item
author M., Awan
D., Ismoyo
N., Yahya
author_facet M., Awan
D., Ismoyo
N., Yahya
author_sort M., Awan
title Harmonic analysis of 240V AC power supply using TMS320C6713 DSK
title_short Harmonic analysis of 240V AC power supply using TMS320C6713 DSK
title_full Harmonic analysis of 240V AC power supply using TMS320C6713 DSK
title_fullStr Harmonic analysis of 240V AC power supply using TMS320C6713 DSK
title_full_unstemmed Harmonic analysis of 240V AC power supply using TMS320C6713 DSK
title_sort harmonic analysis of 240v ac power supply using tms320c6713 dsk
publishDate 2009
url http://eprints.utp.edu.my/340/1/paper.pdf
http://www.scopus.com/inward/record.url?eid=2-s2.0-70449673244&partnerID=40&md5=252241b3ce924d474a8d187e94949a4a
http://eprints.utp.edu.my/340/
_version_ 1738655054659846144
score 13.160551