Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method

In this study, the air side heat transfer coefficient of an aluminium mini-channel heat exchanger was investigated for single-phase flow in the mini-channel, with water in the tubes and air on the outside. Research methods included hydraulic tests on a single mini-channel tube, Wilson Plot experimen...

Full description

Saved in:
Bibliographic Details
Main Authors: Thoo, K.K., Chin, W.M., Heikal, M.R.
Format: Conference or Workshop Item
Published: 2013
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84893613820&doi=10.1088%2f1757-899X%2f50%2f1%2f012024&partnerID=40&md5=e080138dd735805491e2da5fc67d401a
http://eprints.utp.edu.my/32525/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.32525
record_format eprints
spelling my.utp.eprints.325252022-03-29T14:04:51Z Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method Thoo, K.K. Chin, W.M. Heikal, M.R. In this study, the air side heat transfer coefficient of an aluminium mini-channel heat exchanger was investigated for single-phase flow in the mini-channel, with water in the tubes and air on the outside. Research methods included hydraulic tests on a single mini-channel tube, Wilson Plot experiments and experiment validation. Results obtained from the hydraulic test showed that turbulent flow occurred in the tube at a Reynolds number of 830. Wilson Plot experiments were conducted to determine air side heat transfer coefficient of the heat exchanger. The tube side Reynolds number was maintained above 1000 to ensure turbulent flow and tube side heat transfer coefficient was calculated using Gnielinski equation for turbulent flow. The air side heat transfer coefficients obtained from the Wilson Plot experiments were in good agreement with known correlations. The outcome of this study is to use the air side heat transfer coefficient to calculate the performance of refrigerant condensers for different tube pass ratios and flow pass configurations. © Published under licence by IOP Publishing Ltd. 2013 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84893613820&doi=10.1088%2f1757-899X%2f50%2f1%2f012024&partnerID=40&md5=e080138dd735805491e2da5fc67d401a Thoo, K.K. and Chin, W.M. and Heikal, M.R. (2013) Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method. In: UNSPECIFIED. http://eprints.utp.edu.my/32525/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description In this study, the air side heat transfer coefficient of an aluminium mini-channel heat exchanger was investigated for single-phase flow in the mini-channel, with water in the tubes and air on the outside. Research methods included hydraulic tests on a single mini-channel tube, Wilson Plot experiments and experiment validation. Results obtained from the hydraulic test showed that turbulent flow occurred in the tube at a Reynolds number of 830. Wilson Plot experiments were conducted to determine air side heat transfer coefficient of the heat exchanger. The tube side Reynolds number was maintained above 1000 to ensure turbulent flow and tube side heat transfer coefficient was calculated using Gnielinski equation for turbulent flow. The air side heat transfer coefficients obtained from the Wilson Plot experiments were in good agreement with known correlations. The outcome of this study is to use the air side heat transfer coefficient to calculate the performance of refrigerant condensers for different tube pass ratios and flow pass configurations. © Published under licence by IOP Publishing Ltd.
format Conference or Workshop Item
author Thoo, K.K.
Chin, W.M.
Heikal, M.R.
spellingShingle Thoo, K.K.
Chin, W.M.
Heikal, M.R.
Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method
author_facet Thoo, K.K.
Chin, W.M.
Heikal, M.R.
author_sort Thoo, K.K.
title Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method
title_short Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method
title_full Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method
title_fullStr Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method
title_full_unstemmed Determination of air side heat transfer coefficient in a mini-channel heat exchanger using Wilson Plot method
title_sort determination of air side heat transfer coefficient in a mini-channel heat exchanger using wilson plot method
publishDate 2013
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84893613820&doi=10.1088%2f1757-899X%2f50%2f1%2f012024&partnerID=40&md5=e080138dd735805491e2da5fc67d401a
http://eprints.utp.edu.my/32525/
_version_ 1738657399092281344
score 13.214268