Effect of induced vibration on the blood flow properties in a mechanical aortic valve

The effect of induced vibration on velocity distribution for the blood flow in the bileaflet mechanical heart valves conveying blood was investigated in this study. The bileaflet valve was simulated as an orifice. The induced vibration is due to the pulsed blood flow in the artery. Results presented...

Full description

Saved in:
Bibliographic Details
Main Authors: Kadhim, S.K., Nasif, M.S., Al-Kayiem, H.H., Thirumalaiswany, N., Waked, R.A.
Format: Conference or Workshop Item
Published: EDP Sciences 2014
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905006137&doi=10.1051%2fmatecconf%2f20141302022&partnerID=40&md5=802ee293efc1ef276747bd792a844300
http://eprints.utp.edu.my/32250/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.32250
record_format eprints
spelling my.utp.eprints.322502022-03-29T05:02:26Z Effect of induced vibration on the blood flow properties in a mechanical aortic valve Kadhim, S.K. Nasif, M.S. Al-Kayiem, H.H. Thirumalaiswany, N. Waked, R.A. The effect of induced vibration on velocity distribution for the blood flow in the bileaflet mechanical heart valves conveying blood was investigated in this study. The bileaflet valve was simulated as an orifice. The induced vibration is due to the pulsed blood flow in the artery. Results presented in this study were performed using CFD FLUENT software. This analysis is based on the non-linear numerical solution by using a finite-element method, for the system of governing partial differential equations (continuity, momentum) of Navier - Stokes equation of blood flow through the orifice. It has been found that as the flow through the orifice increased, the vibration at the orifice inlet increased. For steady state conditions, at Reynolds number 50 the recorded frequency was 20Hz. When the Reynolds number increased to 100 due to the increase in the blood flow the recorded frequency increased to 30Hz. The increase in frequency may result in damaging the blood red cells and platelets which subsequently results in increasing the blood clogging downstream of the orifice. © 2014 Owned by the authors, published by EDP Sciences. EDP Sciences 2014 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905006137&doi=10.1051%2fmatecconf%2f20141302022&partnerID=40&md5=802ee293efc1ef276747bd792a844300 Kadhim, S.K. and Nasif, M.S. and Al-Kayiem, H.H. and Thirumalaiswany, N. and Waked, R.A. (2014) Effect of induced vibration on the blood flow properties in a mechanical aortic valve. In: UNSPECIFIED. http://eprints.utp.edu.my/32250/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description The effect of induced vibration on velocity distribution for the blood flow in the bileaflet mechanical heart valves conveying blood was investigated in this study. The bileaflet valve was simulated as an orifice. The induced vibration is due to the pulsed blood flow in the artery. Results presented in this study were performed using CFD FLUENT software. This analysis is based on the non-linear numerical solution by using a finite-element method, for the system of governing partial differential equations (continuity, momentum) of Navier - Stokes equation of blood flow through the orifice. It has been found that as the flow through the orifice increased, the vibration at the orifice inlet increased. For steady state conditions, at Reynolds number 50 the recorded frequency was 20Hz. When the Reynolds number increased to 100 due to the increase in the blood flow the recorded frequency increased to 30Hz. The increase in frequency may result in damaging the blood red cells and platelets which subsequently results in increasing the blood clogging downstream of the orifice. © 2014 Owned by the authors, published by EDP Sciences.
format Conference or Workshop Item
author Kadhim, S.K.
Nasif, M.S.
Al-Kayiem, H.H.
Thirumalaiswany, N.
Waked, R.A.
spellingShingle Kadhim, S.K.
Nasif, M.S.
Al-Kayiem, H.H.
Thirumalaiswany, N.
Waked, R.A.
Effect of induced vibration on the blood flow properties in a mechanical aortic valve
author_facet Kadhim, S.K.
Nasif, M.S.
Al-Kayiem, H.H.
Thirumalaiswany, N.
Waked, R.A.
author_sort Kadhim, S.K.
title Effect of induced vibration on the blood flow properties in a mechanical aortic valve
title_short Effect of induced vibration on the blood flow properties in a mechanical aortic valve
title_full Effect of induced vibration on the blood flow properties in a mechanical aortic valve
title_fullStr Effect of induced vibration on the blood flow properties in a mechanical aortic valve
title_full_unstemmed Effect of induced vibration on the blood flow properties in a mechanical aortic valve
title_sort effect of induced vibration on the blood flow properties in a mechanical aortic valve
publisher EDP Sciences
publishDate 2014
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84905006137&doi=10.1051%2fmatecconf%2f20141302022&partnerID=40&md5=802ee293efc1ef276747bd792a844300
http://eprints.utp.edu.my/32250/
_version_ 1738657361147461632
score 13.160551