Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA
Concurrent electroencephalograph (EEG) and functional magnetic resonance image (fMRI) led researchers to acquire neuronal activities in detail over the past few decades. Regardless of the advantages of combining these modalities, artifacts posed a greater challenge to attain good quality data. One s...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
IEEE Computer Society
2014
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-84906350477&doi=10.1109%2fICIAS.2014.6869512&partnerID=40&md5=a09d111bb23e578a5590475de446758d http://eprints.utp.edu.my/32102/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.32102 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.321022022-03-29T04:34:38Z Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA Javed, E. Faye, I. Malik, A.S. Abdullah, J.M. Concurrent electroencephalograph (EEG) and functional magnetic resonance image (fMRI) led researchers to acquire neuronal activities in detail over the past few decades. Regardless of the advantages of combining these modalities, artifacts posed a greater challenge to attain good quality data. One such problematic artifact which contaminates EEG recordings is Ballistocardiogram (BCG) artifact. A reference-free composite algorithm which combines empirical mode decomposition (EMD) and principal component analysis (PCA) named as EMD-PCA has been introduced in this study. The results show that the algorithm can efficiently reduce the BCG artifact by preserving original neuronal signals. The proposed algorithm showed improvement in reducing the BCG artifact as well as in the preservation of brain activities, when compared with two renowned existing methods that are average artifact subtraction (AAS) and optimal basis set (OBS). © 2014 IEEE. IEEE Computer Society 2014 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84906350477&doi=10.1109%2fICIAS.2014.6869512&partnerID=40&md5=a09d111bb23e578a5590475de446758d Javed, E. and Faye, I. and Malik, A.S. and Abdullah, J.M. (2014) Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA. In: UNSPECIFIED. http://eprints.utp.edu.my/32102/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Concurrent electroencephalograph (EEG) and functional magnetic resonance image (fMRI) led researchers to acquire neuronal activities in detail over the past few decades. Regardless of the advantages of combining these modalities, artifacts posed a greater challenge to attain good quality data. One such problematic artifact which contaminates EEG recordings is Ballistocardiogram (BCG) artifact. A reference-free composite algorithm which combines empirical mode decomposition (EMD) and principal component analysis (PCA) named as EMD-PCA has been introduced in this study. The results show that the algorithm can efficiently reduce the BCG artifact by preserving original neuronal signals. The proposed algorithm showed improvement in reducing the BCG artifact as well as in the preservation of brain activities, when compared with two renowned existing methods that are average artifact subtraction (AAS) and optimal basis set (OBS). © 2014 IEEE. |
format |
Conference or Workshop Item |
author |
Javed, E. Faye, I. Malik, A.S. Abdullah, J.M. |
spellingShingle |
Javed, E. Faye, I. Malik, A.S. Abdullah, J.M. Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA |
author_facet |
Javed, E. Faye, I. Malik, A.S. Abdullah, J.M. |
author_sort |
Javed, E. |
title |
Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA |
title_short |
Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA |
title_full |
Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA |
title_fullStr |
Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA |
title_full_unstemmed |
Reference-free reduction of ballistocardiogram artifact from EEG data using EMD-PCA |
title_sort |
reference-free reduction of ballistocardiogram artifact from eeg data using emd-pca |
publisher |
IEEE Computer Society |
publishDate |
2014 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-84906350477&doi=10.1109%2fICIAS.2014.6869512&partnerID=40&md5=a09d111bb23e578a5590475de446758d http://eprints.utp.edu.my/32102/ |
_version_ |
1738657340407676928 |
score |
13.209306 |