The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application

Test interval is an action to verify Safety Integrity Function (SIF) availability. The detection of SIF availability is depends on appropriate test interval value. The test interval value could affect the value of Safety Integrity Level (SIL). This research proposed to demonstrate the effect of the...

Full description

Saved in:
Bibliographic Details
Main Authors: Biyanto, T.R., Natawiria, A.D.S., Kusuma, F., Musyafa, A., Noriyati, R.D., Costa, S.D., Irawan, S.
Format: Conference or Workshop Item
Published: Society of Petroleum Engineers 2015
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85085405503&doi=10.2118%2f176307-ms&partnerID=40&md5=6f91a1bb6e06cc2e54659b7c17f95d97
http://eprints.utp.edu.my/30753/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.30753
record_format eprints
spelling my.utp.eprints.307532022-03-25T07:16:58Z The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application Biyanto, T.R. Natawiria, A.D.S. Kusuma, F. Musyafa, A. Noriyati, R.D. Costa, S.D. Irawan, S. Test interval is an action to verify Safety Integrity Function (SIF) availability. The detection of SIF availability is depends on appropriate test interval value. The test interval value could affect the value of Safety Integrity Level (SIL). This research proposed to demonstrate the effect of the test interval to the obtained value for the specified SIL on SIF. Therefore, SIL value will fit into the architecture of SIF. The case study that used in this paper is three phases separator. The save guards installed in this case are pressure SIF and the relief valve. The result of this research proved that the increasing value of test interval could increase the SIL value. The three phases separator case study with specific hazardous event frequency shown that 0.2 years or 2.4 months is the appropriate value for the test interval. Copyright 2015, Society of Petroleum Engineers. Society of Petroleum Engineers 2015 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85085405503&doi=10.2118%2f176307-ms&partnerID=40&md5=6f91a1bb6e06cc2e54659b7c17f95d97 Biyanto, T.R. and Natawiria, A.D.S. and Kusuma, F. and Musyafa, A. and Noriyati, R.D. and Costa, S.D. and Irawan, S. (2015) The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application. In: UNSPECIFIED. http://eprints.utp.edu.my/30753/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description Test interval is an action to verify Safety Integrity Function (SIF) availability. The detection of SIF availability is depends on appropriate test interval value. The test interval value could affect the value of Safety Integrity Level (SIL). This research proposed to demonstrate the effect of the test interval to the obtained value for the specified SIL on SIF. Therefore, SIL value will fit into the architecture of SIF. The case study that used in this paper is three phases separator. The save guards installed in this case are pressure SIF and the relief valve. The result of this research proved that the increasing value of test interval could increase the SIL value. The three phases separator case study with specific hazardous event frequency shown that 0.2 years or 2.4 months is the appropriate value for the test interval. Copyright 2015, Society of Petroleum Engineers.
format Conference or Workshop Item
author Biyanto, T.R.
Natawiria, A.D.S.
Kusuma, F.
Musyafa, A.
Noriyati, R.D.
Costa, S.D.
Irawan, S.
spellingShingle Biyanto, T.R.
Natawiria, A.D.S.
Kusuma, F.
Musyafa, A.
Noriyati, R.D.
Costa, S.D.
Irawan, S.
The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application
author_facet Biyanto, T.R.
Natawiria, A.D.S.
Kusuma, F.
Musyafa, A.
Noriyati, R.D.
Costa, S.D.
Irawan, S.
author_sort Biyanto, T.R.
title The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application
title_short The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application
title_full The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application
title_fullStr The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application
title_full_unstemmed The effects of test interval on safety instrumented function (SIF) according to Safety Integrity Level (SIL) value on three phase separator application
title_sort effects of test interval on safety instrumented function (sif) according to safety integrity level (sil) value on three phase separator application
publisher Society of Petroleum Engineers
publishDate 2015
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85085405503&doi=10.2118%2f176307-ms&partnerID=40&md5=6f91a1bb6e06cc2e54659b7c17f95d97
http://eprints.utp.edu.my/30753/
_version_ 1738657151900975104
score 13.209306