Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity

In this research; the degree of hydration of the pastes and the compressive strength of the 50 mm cubes prepared with the 100% cement and fly ash blended cement was determined. 24 hours after casting mortar cubes and the paste samples were cured for 28 days in the fog room. After 28 days curing;...

Full description

Saved in:
Bibliographic Details
Main Authors: Shafiq, Nasir, Nuruddin, Fadhil
Format: Article
Published: 2010
Subjects:
Online Access:http://eprints.utp.edu.my/2959/1/92-360-1-PB.pdf
http://eprints.utp.edu.my/2959/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.2959
record_format eprints
spelling my.utp.eprints.29592017-01-19T08:23:51Z Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity Shafiq, Nasir Nuruddin, Fadhil TA Engineering (General). Civil engineering (General) In this research; the degree of hydration of the pastes and the compressive strength of the 50 mm cubes prepared with the 100% cement and fly ash blended cement was determined. 24 hours after casting mortar cubes and the paste samples were cured for 28 days in the fog room. After 28 days curing; a set of 3 cubes and a paste sample was dried in the 100%, 75%, 65%, 40% and 12% ambient relative humidity at the constant temperature of 27oC. Drying conditions showed significant effects on the compressive strength and the degree of hydration. Highest compressive strength of 70 MPa was measured for mortar cubes dried in 100% RH; similarly 97% degree of hydration was determined for 100% cement samples dried in the 100% RH. For mortar cubes dried in 12% RH, the compressive strength was measured between 47 and 53 MPa. The similar paste samples showed the maximum degree of hydration as 81%. In conclusion, drying conditions have significant effects on the degree of hydration of cement pastes, therefore other properties are also affected such as compressive strength. 2010-09 Article PeerReviewed application/pdf http://eprints.utp.edu.my/2959/1/92-360-1-PB.pdf Shafiq, Nasir and Nuruddin, Fadhil (2010) Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity. Concrete Research Letter . http://eprints.utp.edu.my/2959/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Shafiq, Nasir
Nuruddin, Fadhil
Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity
description In this research; the degree of hydration of the pastes and the compressive strength of the 50 mm cubes prepared with the 100% cement and fly ash blended cement was determined. 24 hours after casting mortar cubes and the paste samples were cured for 28 days in the fog room. After 28 days curing; a set of 3 cubes and a paste sample was dried in the 100%, 75%, 65%, 40% and 12% ambient relative humidity at the constant temperature of 27oC. Drying conditions showed significant effects on the compressive strength and the degree of hydration. Highest compressive strength of 70 MPa was measured for mortar cubes dried in 100% RH; similarly 97% degree of hydration was determined for 100% cement samples dried in the 100% RH. For mortar cubes dried in 12% RH, the compressive strength was measured between 47 and 53 MPa. The similar paste samples showed the maximum degree of hydration as 81%. In conclusion, drying conditions have significant effects on the degree of hydration of cement pastes, therefore other properties are also affected such as compressive strength.
format Article
author Shafiq, Nasir
Nuruddin, Fadhil
author_facet Shafiq, Nasir
Nuruddin, Fadhil
author_sort Shafiq, Nasir
title Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity
title_short Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity
title_full Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity
title_fullStr Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity
title_full_unstemmed Degree of hydration of OPC and OPC/FA pastes dried in different relative humidity
title_sort degree of hydration of opc and opc/fa pastes dried in different relative humidity
publishDate 2010
url http://eprints.utp.edu.my/2959/1/92-360-1-PB.pdf
http://eprints.utp.edu.my/2959/
_version_ 1738655234848194560
score 13.209306