Design of a Field Mill Device for Measuring the High Voltage DC Fields

This paper presents the design, development and realization of a field mill for accurately measuring the DC field. In this research study, a typical capacitor, comprising of one fixed electrode and another rotating electrode is used. A controlled DC motor based on PWM (Pulse Width Modulation) techni...

Full description

Saved in:
Bibliographic Details
Main Authors: Rehman, M., Nallagownden, P., Bhayo, M.A., Baharudin, Z., Baba, M.
Format: Conference or Workshop Item
Published: Institute of Electrical and Electronics Engineers Inc. 2021
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124147243&doi=10.1109%2fICIAS49414.2021.9642531&partnerID=40&md5=82ee5cc11eb18d3c9d26bc69897aab64
http://eprints.utp.edu.my/29203/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.29203
record_format eprints
spelling my.utp.eprints.292032022-03-25T01:11:44Z Design of a Field Mill Device for Measuring the High Voltage DC Fields Rehman, M. Nallagownden, P. Bhayo, M.A. Baharudin, Z. Baba, M. This paper presents the design, development and realization of a field mill for accurately measuring the DC field. In this research study, a typical capacitor, comprising of one fixed electrode and another rotating electrode is used. A controlled DC motor based on PWM (Pulse Width Modulation) technique is used which drives the rotating electrode of the capacitor. The ATmega8 microcontroller is employed, mainly, for analog to digital conversion, PWM generation and for reading the output of the photoelectric sensor. The programming of the ATmega8 microcontroller is done in C-language; WinAVR tool is used for the programming. The performance of the developed field mill is analyzed by creating the DC electric field in the laboratory environment with the help of parallel plate capacitor. A regulated HVDC supply setup is also built for parallel plate capacitor. The developed field mill was tested under positive as well as negative polarity. The proposed field mill is portable, it can be used anywhere to measure the DC field. The development details, mechanical, electrical and electronic components used, and the experimental results are presented in this paper. The overall results show that the developed field mill device can measure the DC field up to the range of ± 65 kV/m, with standard deviation of only ± 2.42. © 2021 IEEE. Institute of Electrical and Electronics Engineers Inc. 2021 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124147243&doi=10.1109%2fICIAS49414.2021.9642531&partnerID=40&md5=82ee5cc11eb18d3c9d26bc69897aab64 Rehman, M. and Nallagownden, P. and Bhayo, M.A. and Baharudin, Z. and Baba, M. (2021) Design of a Field Mill Device for Measuring the High Voltage DC Fields. In: UNSPECIFIED. http://eprints.utp.edu.my/29203/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description This paper presents the design, development and realization of a field mill for accurately measuring the DC field. In this research study, a typical capacitor, comprising of one fixed electrode and another rotating electrode is used. A controlled DC motor based on PWM (Pulse Width Modulation) technique is used which drives the rotating electrode of the capacitor. The ATmega8 microcontroller is employed, mainly, for analog to digital conversion, PWM generation and for reading the output of the photoelectric sensor. The programming of the ATmega8 microcontroller is done in C-language; WinAVR tool is used for the programming. The performance of the developed field mill is analyzed by creating the DC electric field in the laboratory environment with the help of parallel plate capacitor. A regulated HVDC supply setup is also built for parallel plate capacitor. The developed field mill was tested under positive as well as negative polarity. The proposed field mill is portable, it can be used anywhere to measure the DC field. The development details, mechanical, electrical and electronic components used, and the experimental results are presented in this paper. The overall results show that the developed field mill device can measure the DC field up to the range of ± 65 kV/m, with standard deviation of only ± 2.42. © 2021 IEEE.
format Conference or Workshop Item
author Rehman, M.
Nallagownden, P.
Bhayo, M.A.
Baharudin, Z.
Baba, M.
spellingShingle Rehman, M.
Nallagownden, P.
Bhayo, M.A.
Baharudin, Z.
Baba, M.
Design of a Field Mill Device for Measuring the High Voltage DC Fields
author_facet Rehman, M.
Nallagownden, P.
Bhayo, M.A.
Baharudin, Z.
Baba, M.
author_sort Rehman, M.
title Design of a Field Mill Device for Measuring the High Voltage DC Fields
title_short Design of a Field Mill Device for Measuring the High Voltage DC Fields
title_full Design of a Field Mill Device for Measuring the High Voltage DC Fields
title_fullStr Design of a Field Mill Device for Measuring the High Voltage DC Fields
title_full_unstemmed Design of a Field Mill Device for Measuring the High Voltage DC Fields
title_sort design of a field mill device for measuring the high voltage dc fields
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2021
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85124147243&doi=10.1109%2fICIAS49414.2021.9642531&partnerID=40&md5=82ee5cc11eb18d3c9d26bc69897aab64
http://eprints.utp.edu.my/29203/
_version_ 1738656932579770368
score 13.214268