Drag reduction in co-current down flow packed column using xanthan gum

Abstract−Drag reduction is one of the most important techniques for reducing energy consumption in a packed bed contactor. The present work involves an experimental investigation on flow regime transition for air-water system with and without drag reducing agent (DRA), two-phase pressure drop, fri...

Full description

Saved in:
Bibliographic Details
Main Authors: Iyyaswami, Regupathi, P. E, JagadeeshBabu, M, Chitra, T., Murugesan
Format: Article
Published: Springer 2010
Subjects:
Online Access:http://eprints.utp.edu.my/2680/1/Drag_KICHE_-_1.pdf
http://www.springer.com/chemistry/journal/11814
http://eprints.utp.edu.my/2680/
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Abstract−Drag reduction is one of the most important techniques for reducing energy consumption in a packed bed contactor. The present work involves an experimental investigation on flow regime transition for air-water system with and without drag reducing agent (DRA), two-phase pressure drop, friction factor and drag reduction using xanthan gum as DRA. Drag reduction was quantified from the two-phase pressure drop data. Based on the present observations it was found that the percentage drag reduction increases with an increase in the concentration of DRA and it is only effective in the range of 300 ppm to 800 ppm. The experimental results indicate that a maximum of 80% drag reduction was achievable using xanthan gum (800 ppm) as DRA. Furthermore, the experimental data were validated with the available literature correlations.