A Study on the Use of Orifice Plates as Steam Traps

Steam traps are vital part in most steam systems in order to prevent the passage of the hot vapor while allowing water condensate to flow. A conventional steam trap is simply a self-actuating valve that opens in the presence of condensate and closes in the presence of steam. These traps all have mov...

Full description

Saved in:
Bibliographic Details
Main Authors: Sulaiman, S. A., Jamaludin, S. E.
Format: Conference or Workshop Item
Published: 2010
Subjects:
Online Access:http://eprints.utp.edu.my/2664/1/ICPER_Shakawi.pdf
http://eprints.utp.edu.my/2664/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.2664
record_format eprints
spelling my.utp.eprints.26642017-01-19T08:24:58Z A Study on the Use of Orifice Plates as Steam Traps Sulaiman, S. A. Jamaludin, S. E. TJ Mechanical engineering and machinery Steam traps are vital part in most steam systems in order to prevent the passage of the hot vapor while allowing water condensate to flow. A conventional steam trap is simply a self-actuating valve that opens in the presence of condensate and closes in the presence of steam. These traps all have moving parts, which, in time will fail. Another non-conventional type of steam trap is known as orifice plate steam trap. The design consist a plate with small hole at the middle to allow condensate to pass through it. The trap uses the condensate within its orifice to hold back steam, rather than any valve arrangement. Orifice plate steam traps have no moving parts that can malfunction, and thus it has minimal problems that are related to mechanical failure. Under certain circumstances, orifice steam traps could function better than the conventional traps. However the performance of orifice plate steam traps is not well understood. The purpose of this paper is to compare the effectiveness of fixed orifice plate steam traps over variable loads. This is achieved by conducting experiments that measure the rate of steam loss under different condensate loads. It is found that fixed orifice plates are only suitable for a steam system with constant condensate load. 2010 Conference or Workshop Item PeerReviewed application/pdf http://eprints.utp.edu.my/2664/1/ICPER_Shakawi.pdf Sulaiman, S. A. and Jamaludin, S. E. (2010) A Study on the Use of Orifice Plates as Steam Traps. In: International Conference on Plant Equipment and Reliability (ICPER), June 2010, Kuala Lumpur. http://eprints.utp.edu.my/2664/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Sulaiman, S. A.
Jamaludin, S. E.
A Study on the Use of Orifice Plates as Steam Traps
description Steam traps are vital part in most steam systems in order to prevent the passage of the hot vapor while allowing water condensate to flow. A conventional steam trap is simply a self-actuating valve that opens in the presence of condensate and closes in the presence of steam. These traps all have moving parts, which, in time will fail. Another non-conventional type of steam trap is known as orifice plate steam trap. The design consist a plate with small hole at the middle to allow condensate to pass through it. The trap uses the condensate within its orifice to hold back steam, rather than any valve arrangement. Orifice plate steam traps have no moving parts that can malfunction, and thus it has minimal problems that are related to mechanical failure. Under certain circumstances, orifice steam traps could function better than the conventional traps. However the performance of orifice plate steam traps is not well understood. The purpose of this paper is to compare the effectiveness of fixed orifice plate steam traps over variable loads. This is achieved by conducting experiments that measure the rate of steam loss under different condensate loads. It is found that fixed orifice plates are only suitable for a steam system with constant condensate load.
format Conference or Workshop Item
author Sulaiman, S. A.
Jamaludin, S. E.
author_facet Sulaiman, S. A.
Jamaludin, S. E.
author_sort Sulaiman, S. A.
title A Study on the Use of Orifice Plates as Steam Traps
title_short A Study on the Use of Orifice Plates as Steam Traps
title_full A Study on the Use of Orifice Plates as Steam Traps
title_fullStr A Study on the Use of Orifice Plates as Steam Traps
title_full_unstemmed A Study on the Use of Orifice Plates as Steam Traps
title_sort study on the use of orifice plates as steam traps
publishDate 2010
url http://eprints.utp.edu.my/2664/1/ICPER_Shakawi.pdf
http://eprints.utp.edu.my/2664/
_version_ 1738655209347874816
score 13.160551