Convertible active power filter: A new approach to compensate for current quality problems in the DS

This paper presents a new moveable power quality (PQ) conditioner named convertible active power filter (CAPF) which aims to compensate for current quality (CQ) problems in the industrial, commercial or residential areas. The proposed CAPF has the capability and flexibility to change its compensatio...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohammed, B.S., Ibrahim, R.B.
Format: Conference or Workshop Item
Published: Institute of Electrical and Electronics Engineers Inc. 2015
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-84962428812&doi=10.1109%2fAUPEC.2015.7324881&partnerID=40&md5=a37f8f9691db9e3363cae47ba9b74264
http://eprints.utp.edu.my/26190/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.26190
record_format eprints
spelling my.utp.eprints.261902021-08-30T08:54:05Z Convertible active power filter: A new approach to compensate for current quality problems in the DS Mohammed, B.S. Ibrahim, R.B. This paper presents a new moveable power quality (PQ) conditioner named convertible active power filter (CAPF) which aims to compensate for current quality (CQ) problems in the industrial, commercial or residential areas. The proposed CAPF has the capability and flexibility to change its compensation mode from load-To-load based on the variations of the load characteristics. This is absolutely necessary in distribution systems because the behavior of the consumer appliances varies continuously. The proposed controller algorithm which is based on the adaptive neural network (ADLINE) and fuzzy logic controller (FLC) is responsible for monitoring the CQ of each load and invoking the CAPF to start the compensation job by connecting the voltage source converter (VSC) based CAPF automatically to the corresponding load based on the total harmonic distortion (THD) of each load, sensitivity of the load to the CQ problems or changes in the load conditions. Power system electromagnetic transient simulation program (PSCAD/EMTDC) is used to simulate the CAPF, the simulation results showed that the proposed CAPF is capable to change its compensation mode from load-To-load to improve the PQ of the selected load based on the existence of CQ problems in the system or change in the load conditions. © 2015 IEEE. Institute of Electrical and Electronics Engineers Inc. 2015 Conference or Workshop Item NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-84962428812&doi=10.1109%2fAUPEC.2015.7324881&partnerID=40&md5=a37f8f9691db9e3363cae47ba9b74264 Mohammed, B.S. and Ibrahim, R.B. (2015) Convertible active power filter: A new approach to compensate for current quality problems in the DS. In: UNSPECIFIED. http://eprints.utp.edu.my/26190/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description This paper presents a new moveable power quality (PQ) conditioner named convertible active power filter (CAPF) which aims to compensate for current quality (CQ) problems in the industrial, commercial or residential areas. The proposed CAPF has the capability and flexibility to change its compensation mode from load-To-load based on the variations of the load characteristics. This is absolutely necessary in distribution systems because the behavior of the consumer appliances varies continuously. The proposed controller algorithm which is based on the adaptive neural network (ADLINE) and fuzzy logic controller (FLC) is responsible for monitoring the CQ of each load and invoking the CAPF to start the compensation job by connecting the voltage source converter (VSC) based CAPF automatically to the corresponding load based on the total harmonic distortion (THD) of each load, sensitivity of the load to the CQ problems or changes in the load conditions. Power system electromagnetic transient simulation program (PSCAD/EMTDC) is used to simulate the CAPF, the simulation results showed that the proposed CAPF is capable to change its compensation mode from load-To-load to improve the PQ of the selected load based on the existence of CQ problems in the system or change in the load conditions. © 2015 IEEE.
format Conference or Workshop Item
author Mohammed, B.S.
Ibrahim, R.B.
spellingShingle Mohammed, B.S.
Ibrahim, R.B.
Convertible active power filter: A new approach to compensate for current quality problems in the DS
author_facet Mohammed, B.S.
Ibrahim, R.B.
author_sort Mohammed, B.S.
title Convertible active power filter: A new approach to compensate for current quality problems in the DS
title_short Convertible active power filter: A new approach to compensate for current quality problems in the DS
title_full Convertible active power filter: A new approach to compensate for current quality problems in the DS
title_fullStr Convertible active power filter: A new approach to compensate for current quality problems in the DS
title_full_unstemmed Convertible active power filter: A new approach to compensate for current quality problems in the DS
title_sort convertible active power filter: a new approach to compensate for current quality problems in the ds
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2015
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-84962428812&doi=10.1109%2fAUPEC.2015.7324881&partnerID=40&md5=a37f8f9691db9e3363cae47ba9b74264
http://eprints.utp.edu.my/26190/
_version_ 1738656836571103232
score 13.211869