Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow
Due to the complex flow structures of two-phase flow, the holdup measurement is a very challenging problem. In this paper, we use the finite element method to analyse a three-dimensional model of concave capacitance sensor. Both two-plate and four-plate sensors are investigated and compared in terms...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Published: |
Asian Research Publishing Network
2016
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009174909&partnerID=40&md5=7eda9bfc3fa6d9e919f3f5b8ed4028b2 http://eprints.utp.edu.my/25336/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.25336 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.253362021-08-27T12:58:23Z Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow Huat, B.Y. Ghai, L.L. Pao, W. Boon, T.T. Due to the complex flow structures of two-phase flow, the holdup measurement is a very challenging problem. In this paper, we use the finite element method to analyse a three-dimensional model of concave capacitance sensor. Both two-plate and four-plate sensors are investigated and compared in terms of the average sensitivity and sensitivity variation parameters. The average sensitivity of sensors is greatly increased during the shift from two-plate design to four-plate design. However, this causes the sensitivity variation parameter to be increased despite the usage of more plates. The geometry of the concave capacitance sensor is determined be 40° electrode angle for four-plate design has a better result as compared to 80° electrode angle of two-plate design. © 2006-2016 Asian Research Publishing Network (ARPN). All rights reserved. Asian Research Publishing Network 2016 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009174909&partnerID=40&md5=7eda9bfc3fa6d9e919f3f5b8ed4028b2 Huat, B.Y. and Ghai, L.L. and Pao, W. and Boon, T.T. (2016) Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow. ARPN Journal of Engineering and Applied Sciences, 11 (24). pp. 14244-14247. http://eprints.utp.edu.my/25336/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Due to the complex flow structures of two-phase flow, the holdup measurement is a very challenging problem. In this paper, we use the finite element method to analyse a three-dimensional model of concave capacitance sensor. Both two-plate and four-plate sensors are investigated and compared in terms of the average sensitivity and sensitivity variation parameters. The average sensitivity of sensors is greatly increased during the shift from two-plate design to four-plate design. However, this causes the sensitivity variation parameter to be increased despite the usage of more plates. The geometry of the concave capacitance sensor is determined be 40° electrode angle for four-plate design has a better result as compared to 80° electrode angle of two-plate design. © 2006-2016 Asian Research Publishing Network (ARPN). All rights reserved. |
format |
Article |
author |
Huat, B.Y. Ghai, L.L. Pao, W. Boon, T.T. |
spellingShingle |
Huat, B.Y. Ghai, L.L. Pao, W. Boon, T.T. Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow |
author_facet |
Huat, B.Y. Ghai, L.L. Pao, W. Boon, T.T. |
author_sort |
Huat, B.Y. |
title |
Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow |
title_short |
Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow |
title_full |
Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow |
title_fullStr |
Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow |
title_full_unstemmed |
Sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow |
title_sort |
sensitivity analysis of concave capacitance sensors for holdup measurement in two-phase flow |
publisher |
Asian Research Publishing Network |
publishDate |
2016 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85009174909&partnerID=40&md5=7eda9bfc3fa6d9e919f3f5b8ed4028b2 http://eprints.utp.edu.my/25336/ |
_version_ |
1738656715745787904 |
score |
13.160551 |