Human factors influencing the reliability of fire and gas detection system

This paper presents some fundamental factors that influence the reliability of fire and gas (F&G) alarm systems by incorporating human factor's principles. As compared, standard alarm and the safety-related alarm will show two different values of IPF given in process hazard analysis (PHA) s...

Full description

Saved in:
Bibliographic Details
Main Authors: Idris, A.M., Rusli, R., Burok, N.A., Mohd Nabil, N.H., Ab Hadi, N.S., Abdul Karim, A.H.M., Ramli, A.F., Mydin, I.
Format: Article
Published: John Wiley and Sons Inc. 2020
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85076511661&doi=10.1002%2fprs.12116&partnerID=40&md5=3cb153fa1e3c00975deb5d84ecca4eae
http://eprints.utp.edu.my/23368/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.23368
record_format eprints
spelling my.utp.eprints.233682021-08-19T07:23:37Z Human factors influencing the reliability of fire and gas detection system Idris, A.M. Rusli, R. Burok, N.A. Mohd Nabil, N.H. Ab Hadi, N.S. Abdul Karim, A.H.M. Ramli, A.F. Mydin, I. This paper presents some fundamental factors that influence the reliability of fire and gas (F&G) alarm systems by incorporating human factor's principles. As compared, standard alarm and the safety-related alarm will show two different values of IPF given in process hazard analysis (PHA) studies. In this study, fault tree diagram has been used to calculate the process flow diagram (PFD) value, to identify which alarm type could meet the standard of safety integrity level (SIL1) for F&G system for a single train process. Comparison of both alarms is done for three types of selected detectors; flammable gas detectors, flame detectors, and toxic gas detectors. It has been identified that standard alarm for all type of detectors does not meet the SIL1 requirement. Compared to safety-related alarm, all detectors are able to meet the requirement of SIL1. Since the greater IPF will be given for safety-related alarm, it is crucial to study the holistic factor that could maintain the system with good efficiency and performance. The human factor has been identified as the most critical element for safety-related alarm. A complete coordinated approach is needed to ensure the performance and efficiency of the F&G alarm system can be maintained while process plants are able to be safely operated within as low as reasonably achievable region. © 2019 American Institute of Chemical Engineers John Wiley and Sons Inc. 2020 Article NonPeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85076511661&doi=10.1002%2fprs.12116&partnerID=40&md5=3cb153fa1e3c00975deb5d84ecca4eae Idris, A.M. and Rusli, R. and Burok, N.A. and Mohd Nabil, N.H. and Ab Hadi, N.S. and Abdul Karim, A.H.M. and Ramli, A.F. and Mydin, I. (2020) Human factors influencing the reliability of fire and gas detection system. Process Safety Progress, 39 (S1). http://eprints.utp.edu.my/23368/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description This paper presents some fundamental factors that influence the reliability of fire and gas (F&G) alarm systems by incorporating human factor's principles. As compared, standard alarm and the safety-related alarm will show two different values of IPF given in process hazard analysis (PHA) studies. In this study, fault tree diagram has been used to calculate the process flow diagram (PFD) value, to identify which alarm type could meet the standard of safety integrity level (SIL1) for F&G system for a single train process. Comparison of both alarms is done for three types of selected detectors; flammable gas detectors, flame detectors, and toxic gas detectors. It has been identified that standard alarm for all type of detectors does not meet the SIL1 requirement. Compared to safety-related alarm, all detectors are able to meet the requirement of SIL1. Since the greater IPF will be given for safety-related alarm, it is crucial to study the holistic factor that could maintain the system with good efficiency and performance. The human factor has been identified as the most critical element for safety-related alarm. A complete coordinated approach is needed to ensure the performance and efficiency of the F&G alarm system can be maintained while process plants are able to be safely operated within as low as reasonably achievable region. © 2019 American Institute of Chemical Engineers
format Article
author Idris, A.M.
Rusli, R.
Burok, N.A.
Mohd Nabil, N.H.
Ab Hadi, N.S.
Abdul Karim, A.H.M.
Ramli, A.F.
Mydin, I.
spellingShingle Idris, A.M.
Rusli, R.
Burok, N.A.
Mohd Nabil, N.H.
Ab Hadi, N.S.
Abdul Karim, A.H.M.
Ramli, A.F.
Mydin, I.
Human factors influencing the reliability of fire and gas detection system
author_facet Idris, A.M.
Rusli, R.
Burok, N.A.
Mohd Nabil, N.H.
Ab Hadi, N.S.
Abdul Karim, A.H.M.
Ramli, A.F.
Mydin, I.
author_sort Idris, A.M.
title Human factors influencing the reliability of fire and gas detection system
title_short Human factors influencing the reliability of fire and gas detection system
title_full Human factors influencing the reliability of fire and gas detection system
title_fullStr Human factors influencing the reliability of fire and gas detection system
title_full_unstemmed Human factors influencing the reliability of fire and gas detection system
title_sort human factors influencing the reliability of fire and gas detection system
publisher John Wiley and Sons Inc.
publishDate 2020
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85076511661&doi=10.1002%2fprs.12116&partnerID=40&md5=3cb153fa1e3c00975deb5d84ecca4eae
http://eprints.utp.edu.my/23368/
_version_ 1738656462150828032
score 13.160551