An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus

Optimal operation is an important aspect of energy efficiency that can be employed to reduce power consumption. In cooling systems, the chillers consume a large amount of electricity, especially if they are not optimally operated, therefore, they cannot produce the required or rated cooling load cap...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdalla, E.A.H., Nallagownden, P., Nor, N.B.M., Romlie, M.F., Hassan, S.M.
Format: Article
Published: MDPI AG 2018
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85044514241&doi=10.3390%2fen11040719&partnerID=40&md5=0c496568604fabe4a507fdbb80bd6c9b
http://eprints.utp.edu.my/21650/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.21650
record_format eprints
spelling my.utp.eprints.216502018-11-07T03:12:31Z An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus Abdalla, E.A.H. Nallagownden, P. Nor, N.B.M. Romlie, M.F. Hassan, S.M. Optimal operation is an important aspect of energy efficiency that can be employed to reduce power consumption. In cooling systems, the chillers consume a large amount of electricity, especially if they are not optimally operated, therefore, they cannot produce the required or rated cooling load capacity. The objective of this paper is to improve coefficient of performance (COP) for the operation of chillers and to reduce power consumption. Two contributions in this work are: (1) the prediction of a model by using Adaptive Neuro-Fuzzy Inference System (ANFIS)-based Fuzzy Clustering Subtractive (FCS), and (2) the classification and optimization of the predicted models by using an Accelerated Particle Swarm Optimization (APSO) algorithm. Particularly, in contribution (1), two models are developed to predict/assess power consumption and cooling load capacity. While in contribution (2), the predictive model's data obtained are used to classify the operating performance of the chiller and to optimize the model in order to reduce power consumption and cooling capacity. Therefore, data classification by APSO is used to enhance the coefficient of performance (COP). The proposed technique reduces the total power consumption by 33.2 and meets the cooling demand requirements. Also, it improves the cooling performance based on COP, thus resulting in a 15.95 increase in efficiency compared to the existing cooling system. The studied ANFIS-based FCS outperforms the ANFIS-based fuzzy C-means clustering in terms of the regression. Then, the algorithm-based classifier APSO has better results compared to the conventional particle swarm optimization (PSO). The data was acquired from the District Cooling System (DCS) at the Universiti Teknologi Petronas (UTP) campus in Malaysia. © 2018 by the authors. MDPI AG 2018 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85044514241&doi=10.3390%2fen11040719&partnerID=40&md5=0c496568604fabe4a507fdbb80bd6c9b Abdalla, E.A.H. and Nallagownden, P. and Nor, N.B.M. and Romlie, M.F. and Hassan, S.M. (2018) An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus. Energies, 11 (4). http://eprints.utp.edu.my/21650/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description Optimal operation is an important aspect of energy efficiency that can be employed to reduce power consumption. In cooling systems, the chillers consume a large amount of electricity, especially if they are not optimally operated, therefore, they cannot produce the required or rated cooling load capacity. The objective of this paper is to improve coefficient of performance (COP) for the operation of chillers and to reduce power consumption. Two contributions in this work are: (1) the prediction of a model by using Adaptive Neuro-Fuzzy Inference System (ANFIS)-based Fuzzy Clustering Subtractive (FCS), and (2) the classification and optimization of the predicted models by using an Accelerated Particle Swarm Optimization (APSO) algorithm. Particularly, in contribution (1), two models are developed to predict/assess power consumption and cooling load capacity. While in contribution (2), the predictive model's data obtained are used to classify the operating performance of the chiller and to optimize the model in order to reduce power consumption and cooling capacity. Therefore, data classification by APSO is used to enhance the coefficient of performance (COP). The proposed technique reduces the total power consumption by 33.2 and meets the cooling demand requirements. Also, it improves the cooling performance based on COP, thus resulting in a 15.95 increase in efficiency compared to the existing cooling system. The studied ANFIS-based FCS outperforms the ANFIS-based fuzzy C-means clustering in terms of the regression. Then, the algorithm-based classifier APSO has better results compared to the conventional particle swarm optimization (PSO). The data was acquired from the District Cooling System (DCS) at the Universiti Teknologi Petronas (UTP) campus in Malaysia. © 2018 by the authors.
format Article
author Abdalla, E.A.H.
Nallagownden, P.
Nor, N.B.M.
Romlie, M.F.
Hassan, S.M.
spellingShingle Abdalla, E.A.H.
Nallagownden, P.
Nor, N.B.M.
Romlie, M.F.
Hassan, S.M.
An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus
author_facet Abdalla, E.A.H.
Nallagownden, P.
Nor, N.B.M.
Romlie, M.F.
Hassan, S.M.
author_sort Abdalla, E.A.H.
title An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus
title_short An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus
title_full An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus
title_fullStr An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus
title_full_unstemmed An application of a novel technique for assessing the operating performance of existing cooling systems on a university campus
title_sort application of a novel technique for assessing the operating performance of existing cooling systems on a university campus
publisher MDPI AG
publishDate 2018
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85044514241&doi=10.3390%2fen11040719&partnerID=40&md5=0c496568604fabe4a507fdbb80bd6c9b
http://eprints.utp.edu.my/21650/
_version_ 1738656319018106880
score 13.18916