Forearm pressure distribution during ambulation with elbow crutches

This paper studies the pressure distribution on the forearm and the hand palm during ambulation with forearm crutches. It also presents the design, modelling and development of a forearm crutch that is capable of eliminating the high pressure induced on patient's palm and forearm areas while ga...

Full description

Saved in:
Bibliographic Details
Main Authors: Ghalehkhani, P., Parasuraman, S., Khan, M.K.A.A., Elamvazuthi, I., Debnath, N., Ali, S.S.A.
Format: Article
Published: Institute of Electrical and Electronics Engineers Inc. 2017
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85015889983&doi=10.1109%2fROMA.2016.7847823&partnerID=40&md5=527ed35739dfd28cd91a2838fb45de68
http://eprints.utp.edu.my/20156/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.20156
record_format eprints
spelling my.utp.eprints.201562018-04-22T14:43:39Z Forearm pressure distribution during ambulation with elbow crutches Ghalehkhani, P. Parasuraman, S. Khan, M.K.A.A. Elamvazuthi, I. Debnath, N. Ali, S.S.A. This paper studies the pressure distribution on the forearm and the hand palm during ambulation with forearm crutches. It also presents the design, modelling and development of a forearm crutch that is capable of eliminating the high pressure induced on patient's palm and forearm areas while gating; preventing other injuries to the nerves and muscles of the mentioned extremities. Eventually, one of the main objective of conducting this project is to make the patients feel less tired and more comfortable during crutch-aided ambulation. The design of the crutch is drawn using CATIA software, a CAD modelling package. The study on the developed design is to prove that it is of high quality and is more comfortable compared to available regular forearm crutches. It is developed using two experimental methods, namely: Energy Expenditure Index (EEI) and Electromyography (EMG). The experiments related to the mentioned methods have been conducted with the help of 10 healthy/normal volunteers. Also the crutch parts have been simulated using COMSOL Multiphysics Software. Lastly, a survey was prepared and its results are also provided in accordance with the way the patients feel about the developed design. The results of all four methods mentioned, show that the focal pressure on the patient's hand and forearm has been significantly reduced; also, the energy expenditure level has been dropped. It can be concluded that the developed crutch is of high quality and is more comfortable compared to regular forearm crutches. © 2016 IEEE. Institute of Electrical and Electronics Engineers Inc. 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85015889983&doi=10.1109%2fROMA.2016.7847823&partnerID=40&md5=527ed35739dfd28cd91a2838fb45de68 Ghalehkhani, P. and Parasuraman, S. and Khan, M.K.A.A. and Elamvazuthi, I. and Debnath, N. and Ali, S.S.A. (2017) Forearm pressure distribution during ambulation with elbow crutches. 2016 2nd IEEE International Symposium on Robotics and Manufacturing Automation, ROMA 2016 . http://eprints.utp.edu.my/20156/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description This paper studies the pressure distribution on the forearm and the hand palm during ambulation with forearm crutches. It also presents the design, modelling and development of a forearm crutch that is capable of eliminating the high pressure induced on patient's palm and forearm areas while gating; preventing other injuries to the nerves and muscles of the mentioned extremities. Eventually, one of the main objective of conducting this project is to make the patients feel less tired and more comfortable during crutch-aided ambulation. The design of the crutch is drawn using CATIA software, a CAD modelling package. The study on the developed design is to prove that it is of high quality and is more comfortable compared to available regular forearm crutches. It is developed using two experimental methods, namely: Energy Expenditure Index (EEI) and Electromyography (EMG). The experiments related to the mentioned methods have been conducted with the help of 10 healthy/normal volunteers. Also the crutch parts have been simulated using COMSOL Multiphysics Software. Lastly, a survey was prepared and its results are also provided in accordance with the way the patients feel about the developed design. The results of all four methods mentioned, show that the focal pressure on the patient's hand and forearm has been significantly reduced; also, the energy expenditure level has been dropped. It can be concluded that the developed crutch is of high quality and is more comfortable compared to regular forearm crutches. © 2016 IEEE.
format Article
author Ghalehkhani, P.
Parasuraman, S.
Khan, M.K.A.A.
Elamvazuthi, I.
Debnath, N.
Ali, S.S.A.
spellingShingle Ghalehkhani, P.
Parasuraman, S.
Khan, M.K.A.A.
Elamvazuthi, I.
Debnath, N.
Ali, S.S.A.
Forearm pressure distribution during ambulation with elbow crutches
author_facet Ghalehkhani, P.
Parasuraman, S.
Khan, M.K.A.A.
Elamvazuthi, I.
Debnath, N.
Ali, S.S.A.
author_sort Ghalehkhani, P.
title Forearm pressure distribution during ambulation with elbow crutches
title_short Forearm pressure distribution during ambulation with elbow crutches
title_full Forearm pressure distribution during ambulation with elbow crutches
title_fullStr Forearm pressure distribution during ambulation with elbow crutches
title_full_unstemmed Forearm pressure distribution during ambulation with elbow crutches
title_sort forearm pressure distribution during ambulation with elbow crutches
publisher Institute of Electrical and Electronics Engineers Inc.
publishDate 2017
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85015889983&doi=10.1109%2fROMA.2016.7847823&partnerID=40&md5=527ed35739dfd28cd91a2838fb45de68
http://eprints.utp.edu.my/20156/
_version_ 1738656171627118592
score 13.160551