Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing
Flow induced structural stresses can cause mechanical prosthetic aortic valve to fail due to yielding. In this study, we have performed the structural analysis, especially the effect of leaflet thickness on equivalent stresses developed in a Bileaflet mechanical heart valve (BMHV) due to blood flow...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
EDP Sciences
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033236161&doi=10.1051%2fmatecconf%2f201713104004&partnerID=40&md5=1226c05636d104beb5885798ddd8d081 http://eprints.utp.edu.my/19982/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.19982 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.199822018-04-22T14:30:53Z Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing Abbas, S.S. Shakir Nasif, M. Meor Said, M.A. Al-Waked, R. Khalefa Kadhim, S. Flow induced structural stresses can cause mechanical prosthetic aortic valve to fail due to yielding. In this study, we have performed the structural analysis, especially the effect of leaflet thickness on equivalent stresses developed in a Bileaflet mechanical heart valve (BMHV) due to blood flow through it has been investigated. The leaflet thickness varies from 0.5mm to 0.7mm, by 0.1mm. A fluid-structure interaction approach based on Arbitrary Lagrangian Eulerian (ALE) technique has been employed with the aid of an user defined function (UDF). Results of the analysis show that high von Mises stresses are developed in BMHV with leaflet thickness of 0.5mm and 0.6mm, being 75 and 13 higher than allowable equivalent stress respectively. Such thinner leaflets are therefore, not sustainable to be replaced with diseased aortic valve. © The authors, published by EDP Sciences, 2017. EDP Sciences 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033236161&doi=10.1051%2fmatecconf%2f201713104004&partnerID=40&md5=1226c05636d104beb5885798ddd8d081 Abbas, S.S. and Shakir Nasif, M. and Meor Said, M.A. and Al-Waked, R. and Khalefa Kadhim, S. (2017) Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing. MATEC Web of Conferences, 131 . http://eprints.utp.edu.my/19982/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Flow induced structural stresses can cause mechanical prosthetic aortic valve to fail due to yielding. In this study, we have performed the structural analysis, especially the effect of leaflet thickness on equivalent stresses developed in a Bileaflet mechanical heart valve (BMHV) due to blood flow through it has been investigated. The leaflet thickness varies from 0.5mm to 0.7mm, by 0.1mm. A fluid-structure interaction approach based on Arbitrary Lagrangian Eulerian (ALE) technique has been employed with the aid of an user defined function (UDF). Results of the analysis show that high von Mises stresses are developed in BMHV with leaflet thickness of 0.5mm and 0.6mm, being 75 and 13 higher than allowable equivalent stress respectively. Such thinner leaflets are therefore, not sustainable to be replaced with diseased aortic valve. © The authors, published by EDP Sciences, 2017. |
format |
Article |
author |
Abbas, S.S. Shakir Nasif, M. Meor Said, M.A. Al-Waked, R. Khalefa Kadhim, S. |
spellingShingle |
Abbas, S.S. Shakir Nasif, M. Meor Said, M.A. Al-Waked, R. Khalefa Kadhim, S. Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing |
author_facet |
Abbas, S.S. Shakir Nasif, M. Meor Said, M.A. Al-Waked, R. Khalefa Kadhim, S. |
author_sort |
Abbas, S.S. |
title |
Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing |
title_short |
Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing |
title_full |
Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing |
title_fullStr |
Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing |
title_full_unstemmed |
Numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing |
title_sort |
numerical investigation on effect of leaflet thickness on structural stresses developed in a bileaflet mechanical heart valve for its sustainable manufacturing |
publisher |
EDP Sciences |
publishDate |
2017 |
url |
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033236161&doi=10.1051%2fmatecconf%2f201713104004&partnerID=40&md5=1226c05636d104beb5885798ddd8d081 http://eprints.utp.edu.my/19982/ |
_version_ |
1738656146982436864 |
score |