Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET

The aim of this research is to develop a cost effective ultrasonic testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET. Two specimens has been fabricated with 6 different profiles thickness on the first specimen and 3 different profiles thickness on the other spec...

Full description

Saved in:
Bibliographic Details
Main Authors: Zakaria, Z.A., Yaacob, A., Mokri, K.N., Hanaffi, M.S., Zainol, M.Z., Ganesan, L., Ishak, M.F., Majid, M.A., Hasan, K.N.M.
Format: Article
Published: Asian Research Publishing Network 2017
Online Access:https://www.scopus.com/inward/record.uri?eid=2-s2.0-85016055989&partnerID=40&md5=5b25049da583e39971a142c4dc9b6627
http://eprints.utp.edu.my/19600/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utp.eprints.19600
record_format eprints
spelling my.utp.eprints.196002018-04-20T07:14:18Z Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET Zakaria, Z.A. Yaacob, A. Mokri, K.N. Hanaffi, M.S. Zainol, M.Z. Ganesan, L. Ishak, M.F. Majid, M.A. Hasan, K.N.M. The aim of this research is to develop a cost effective ultrasonic testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET. Two specimens has been fabricated with 6 different profiles thickness on the first specimen and 3 different profiles thickness on the other specimen. These profile have been calibrated and tested using Krautkramer USM 35x machine. The thickness and shape of the profile has been determined from the measurement of return ultrasound waves from bottom to the top surface. Then the basic guidelines of the procedure on how to conduct the calibration and testing for thickness measurement has been developed. Finally the "Ultrasonic Testing Laboratory Report " which has been created can be used for the future students in UniKL MIMET to refer as an answer scheme for all 9 different profiles thickness. © 2006-2017 Asian Research Publishing Network (ARPN). All rights reserved. Asian Research Publishing Network 2017 Article PeerReviewed https://www.scopus.com/inward/record.uri?eid=2-s2.0-85016055989&partnerID=40&md5=5b25049da583e39971a142c4dc9b6627 Zakaria, Z.A. and Yaacob, A. and Mokri, K.N. and Hanaffi, M.S. and Zainol, M.Z. and Ganesan, L. and Ishak, M.F. and Majid, M.A. and Hasan, K.N.M. (2017) Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET. ARPN Journal of Engineering and Applied Sciences, 12 (6). pp. 1961-1967. http://eprints.utp.edu.my/19600/
institution Universiti Teknologi Petronas
building UTP Resource Centre
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Petronas
content_source UTP Institutional Repository
url_provider http://eprints.utp.edu.my/
description The aim of this research is to develop a cost effective ultrasonic testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET. Two specimens has been fabricated with 6 different profiles thickness on the first specimen and 3 different profiles thickness on the other specimen. These profile have been calibrated and tested using Krautkramer USM 35x machine. The thickness and shape of the profile has been determined from the measurement of return ultrasound waves from bottom to the top surface. Then the basic guidelines of the procedure on how to conduct the calibration and testing for thickness measurement has been developed. Finally the "Ultrasonic Testing Laboratory Report " which has been created can be used for the future students in UniKL MIMET to refer as an answer scheme for all 9 different profiles thickness. © 2006-2017 Asian Research Publishing Network (ARPN). All rights reserved.
format Article
author Zakaria, Z.A.
Yaacob, A.
Mokri, K.N.
Hanaffi, M.S.
Zainol, M.Z.
Ganesan, L.
Ishak, M.F.
Majid, M.A.
Hasan, K.N.M.
spellingShingle Zakaria, Z.A.
Yaacob, A.
Mokri, K.N.
Hanaffi, M.S.
Zainol, M.Z.
Ganesan, L.
Ishak, M.F.
Majid, M.A.
Hasan, K.N.M.
Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET
author_facet Zakaria, Z.A.
Yaacob, A.
Mokri, K.N.
Hanaffi, M.S.
Zainol, M.Z.
Ganesan, L.
Ishak, M.F.
Majid, M.A.
Hasan, K.N.M.
author_sort Zakaria, Z.A.
title Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET
title_short Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET
title_full Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET
title_fullStr Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET
title_full_unstemmed Development of cost effective Ultrasonic Testing thickness measurement specimens and basic laboratory guidelines for UniKL MIMET
title_sort development of cost effective ultrasonic testing thickness measurement specimens and basic laboratory guidelines for unikl mimet
publisher Asian Research Publishing Network
publishDate 2017
url https://www.scopus.com/inward/record.uri?eid=2-s2.0-85016055989&partnerID=40&md5=5b25049da583e39971a142c4dc9b6627
http://eprints.utp.edu.my/19600/
_version_ 1738656093096116224
score 13.18916