Development of iridium oxide sensor for surface pH measurement of a corroding metal under deposit
A novel method used to design and fabricate a pH sensor for measurement of hydrogen ion activity on corroding metal surface in under deposit. The electrodeposition method of cyclic voltammetry approach is used for coating of Iridium Oxide (IrOX) on stainless steel substrate. The pH value of the X52...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Published: |
Electrochemical Science Group
2017
|
Online Access: | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85033715025&doi=10.20964%2f2017.11.07&partnerID=40&md5=e0403bb79df968b80d333573aca7ea66 http://eprints.utp.edu.my/19299/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Be the first to leave a comment!