Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips
Digital microfluidics biochips has led to the revolution of modern day clinical diagnostics procedures. These biochips enable the use of nano-liter volume of samples and reagents. A more recent architecture of digital microfluidics known as Micro-electrode Dot Array (ME...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Conference or Workshop Item |
Published: |
2016
|
Online Access: | http://eprints.utp.edu.my/11954/1/Investigation%20of%20Capacitance%20Dependence%20on.pdf http://eprints.utp.edu.my/11954/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utp.eprints.11954 |
---|---|
record_format |
eprints |
spelling |
my.utp.eprints.119542017-01-19T08:20:56Z Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips Shukla, Vineeta Hussin, Fawnizu Azmadi Hamid, Nor Hisham Zain Ali , Noohul Basheer Digital microfluidics biochips has led to the revolution of modern day clinical diagnostics procedures. These biochips enable the use of nano-liter volume of samples and reagents. A more recent architecture of digital microfluidics known as Micro-electrode Dot Array (MEDA) has been introduced which incorporate some advance operations like diagonal movement and channel based routing. Owing to this new architecture, there exist some defects which require additional testing techniques. The defect in these biochips is studied by analyzing the capacitance changes at the sensing circuit. An investigation of capacitance of droplet based on the volume variation is done. The motivation behind this study is to see the variation of capacitance due to the defects in the biochips which can occur due to the volume variation of the droplet in MEDA based biochips. It is seen that the capacitance of droplet varies linearly with droplet volume which leads to the conclusion that defects due to the volume variation directly affects the capacitance at the sensing circuit. 2016 Conference or Workshop Item PeerReviewed application/pdf http://eprints.utp.edu.my/11954/1/Investigation%20of%20Capacitance%20Dependence%20on.pdf Shukla, Vineeta and Hussin, Fawnizu Azmadi and Hamid, Nor Hisham and Zain Ali , Noohul Basheer (2016) Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips. In: 6th International Conference on Intelligent and Advanced Systems (ICIAS2016), August 15-17, 2016, Kuala Lumpur Malaysia. (In Press) http://eprints.utp.edu.my/11954/ |
institution |
Universiti Teknologi Petronas |
building |
UTP Resource Centre |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Petronas |
content_source |
UTP Institutional Repository |
url_provider |
http://eprints.utp.edu.my/ |
description |
Digital microfluidics biochips has led to the revolution of modern day clinical diagnostics procedures. These biochips enable the use of nano-liter volume of samples and reagents. A more recent architecture of digital microfluidics known as Micro-electrode Dot Array (MEDA) has been introduced which incorporate some advance operations like diagonal movement and channel based routing. Owing to this new architecture, there exist some defects which require additional testing techniques. The defect in these biochips is studied by analyzing the capacitance changes at the sensing circuit. An investigation of capacitance of droplet based on the volume variation is done. The motivation behind this study is to see the variation of capacitance due to the defects in the biochips which can occur due to the volume variation of the droplet in MEDA based biochips. It is seen that the capacitance of droplet varies linearly with droplet volume which leads to the conclusion that defects due to the volume variation directly affects the capacitance at the sensing circuit. |
format |
Conference or Workshop Item |
author |
Shukla, Vineeta Hussin, Fawnizu Azmadi Hamid, Nor Hisham Zain Ali , Noohul Basheer |
spellingShingle |
Shukla, Vineeta Hussin, Fawnizu Azmadi Hamid, Nor Hisham Zain Ali , Noohul Basheer Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips |
author_facet |
Shukla, Vineeta Hussin, Fawnizu Azmadi Hamid, Nor Hisham Zain Ali , Noohul Basheer |
author_sort |
Shukla, Vineeta |
title |
Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips |
title_short |
Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips |
title_full |
Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips |
title_fullStr |
Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips |
title_full_unstemmed |
Investigation of Capacitance Dependence on Droplet Volume in MEDA Based Biochips |
title_sort |
investigation of capacitance dependence on droplet volume in meda based biochips |
publishDate |
2016 |
url |
http://eprints.utp.edu.my/11954/1/Investigation%20of%20Capacitance%20Dependence%20on.pdf http://eprints.utp.edu.my/11954/ |
_version_ |
1738655993067208704 |
score |
13.211869 |