AlCrN coated WC by PVD at various deposition temperatures

An attempt is made in this work to improve the performance and tool life of the tungsten carbide (WC) coated aluminium chromium nitride (AlCrN) via physical vapor deposition (PVD) method. Various deposition temperatures ranging from 250, 350, 400, and 450o C were investigated to evaluate the charact...

Full description

Saved in:
Bibliographic Details
Main Authors: Rizali, Sahril, Chua, Ling Ling, Abdul Latif, Afif Fiqhry, Umi Nur, Umi Nur, Mat Yajid, Muhammad Azizi, Abdullah, Norazharuddin Shah, Wan Ali, Wan Fahmin Faiz
Format: Conference or Workshop Item
Published: 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/99350/
http://dx.doi.org/10.4028/p-zivv73
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.99350
record_format eprints
spelling my.utm.993502023-02-22T08:34:38Z http://eprints.utm.my/id/eprint/99350/ AlCrN coated WC by PVD at various deposition temperatures Rizali, Sahril Chua, Ling Ling Abdul Latif, Afif Fiqhry Umi Nur, Umi Nur Mat Yajid, Muhammad Azizi Abdullah, Norazharuddin Shah Wan Ali, Wan Fahmin Faiz TJ Mechanical engineering and machinery An attempt is made in this work to improve the performance and tool life of the tungsten carbide (WC) coated aluminium chromium nitride (AlCrN) via physical vapor deposition (PVD) method. Various deposition temperatures ranging from 250, 350, 400, and 450o C were investigated to evaluate the characteristic of coated carbide. Prior to the deposition process, WC surfaces were treated in Murakami’s solution for 15 minutes followed by Caro’s solution for 10 seconds to improve the coating adhesion on WC by the dissolution of cobalt (C); roughened the carbide surface. The thickness of the coated AlCrN increases proportional with higher deposition temperatures (from 1.14 μm to 2.18 μm) and homogenously coated. While XRD analysis observed the presence of AlN and CrN phases attributed to AlCrN coating. The hardness of the coated carbide was highest at 450o C deposition temperature (1325 HV). The qualitative scratch test following ASTM D 3363 indicated that higher temperature (400o C and above) provides good adhesion characteristics between AlCrN coating and WC. 2022 Conference or Workshop Item PeerReviewed Rizali, Sahril and Chua, Ling Ling and Abdul Latif, Afif Fiqhry and Umi Nur, Umi Nur and Mat Yajid, Muhammad Azizi and Abdullah, Norazharuddin Shah and Wan Ali, Wan Fahmin Faiz (2022) AlCrN coated WC by PVD at various deposition temperatures. In: 10th International Conference on X-Rays and Related Techniques in Research and Industry, ICXRI 2021, 18 August 2021 - 19 August 2021, Virtual, Online. http://dx.doi.org/10.4028/p-zivv73
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Rizali, Sahril
Chua, Ling Ling
Abdul Latif, Afif Fiqhry
Umi Nur, Umi Nur
Mat Yajid, Muhammad Azizi
Abdullah, Norazharuddin Shah
Wan Ali, Wan Fahmin Faiz
AlCrN coated WC by PVD at various deposition temperatures
description An attempt is made in this work to improve the performance and tool life of the tungsten carbide (WC) coated aluminium chromium nitride (AlCrN) via physical vapor deposition (PVD) method. Various deposition temperatures ranging from 250, 350, 400, and 450o C were investigated to evaluate the characteristic of coated carbide. Prior to the deposition process, WC surfaces were treated in Murakami’s solution for 15 minutes followed by Caro’s solution for 10 seconds to improve the coating adhesion on WC by the dissolution of cobalt (C); roughened the carbide surface. The thickness of the coated AlCrN increases proportional with higher deposition temperatures (from 1.14 μm to 2.18 μm) and homogenously coated. While XRD analysis observed the presence of AlN and CrN phases attributed to AlCrN coating. The hardness of the coated carbide was highest at 450o C deposition temperature (1325 HV). The qualitative scratch test following ASTM D 3363 indicated that higher temperature (400o C and above) provides good adhesion characteristics between AlCrN coating and WC.
format Conference or Workshop Item
author Rizali, Sahril
Chua, Ling Ling
Abdul Latif, Afif Fiqhry
Umi Nur, Umi Nur
Mat Yajid, Muhammad Azizi
Abdullah, Norazharuddin Shah
Wan Ali, Wan Fahmin Faiz
author_facet Rizali, Sahril
Chua, Ling Ling
Abdul Latif, Afif Fiqhry
Umi Nur, Umi Nur
Mat Yajid, Muhammad Azizi
Abdullah, Norazharuddin Shah
Wan Ali, Wan Fahmin Faiz
author_sort Rizali, Sahril
title AlCrN coated WC by PVD at various deposition temperatures
title_short AlCrN coated WC by PVD at various deposition temperatures
title_full AlCrN coated WC by PVD at various deposition temperatures
title_fullStr AlCrN coated WC by PVD at various deposition temperatures
title_full_unstemmed AlCrN coated WC by PVD at various deposition temperatures
title_sort alcrn coated wc by pvd at various deposition temperatures
publishDate 2022
url http://eprints.utm.my/id/eprint/99350/
http://dx.doi.org/10.4028/p-zivv73
_version_ 1758578055182286848
score 13.214269