Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32

Telehealth plays an even greater role in global healthcare delivery today. Ever since the pandemic strikes the world, the use of healthcare monitoring systems has a massive boost significantly. This paper aims to develop a prototype of a health monitoring device that can be put at a patient home to...

Full description

Saved in:
Bibliographic Details
Main Authors: Ahmad, Robiah, Mad Kaidi, Hazilah, Nordin, Muhammad Noor, Ramli, Aizat Faiz, Abu, Mohd. Azlan, Kadase, Yosof
Format: Conference or Workshop Item
Published: 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/98916/
http://dx.doi.org/10.1109/ICSSA54161.2022.9870943
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.98916
record_format eprints
spelling my.utm.989162023-02-08T05:23:37Z http://eprints.utm.my/id/eprint/98916/ Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32 Ahmad, Robiah Mad Kaidi, Hazilah Nordin, Muhammad Noor Ramli, Aizat Faiz Abu, Mohd. Azlan Kadase, Yosof T Technology (General) Telehealth plays an even greater role in global healthcare delivery today. Ever since the pandemic strikes the world, the use of healthcare monitoring systems has a massive boost significantly. This paper aims to develop a prototype of a health monitoring device that can be put at a patient home to replace traditional physical checkups at the hospital by using MAX30102 PPG module and Infrared temperature sensor with the objective to derive PPG signal into basic health parameters such as heart rate and oxygen saturation from the patient through MAX30102 and to test the accuracy of those parameters with hospital patient monitor. The experiment is done by comparing each parameter for 30 seconds in both devices using index fingers coming from 13 participants. From the results obtained, although heart rate suffers motion artefact compared to the oxygen saturation, each accuracy is still excellent with 89.2 and 97.6 percent. In conclusion, MAX30102 PPG and ECG module can get initial health reading through the PPG signal and solve the problems mentioned. 2022 Conference or Workshop Item PeerReviewed Ahmad, Robiah and Mad Kaidi, Hazilah and Nordin, Muhammad Noor and Ramli, Aizat Faiz and Abu, Mohd. Azlan and Kadase, Yosof (2022) Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32. In: 4th International Conference on Smart Sensors and Application, ICSSA 2022, 26 - 28 July 2022, Kuala Lumpur, Malaysia. http://dx.doi.org/10.1109/ICSSA54161.2022.9870943
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
spellingShingle T Technology (General)
Ahmad, Robiah
Mad Kaidi, Hazilah
Nordin, Muhammad Noor
Ramli, Aizat Faiz
Abu, Mohd. Azlan
Kadase, Yosof
Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32
description Telehealth plays an even greater role in global healthcare delivery today. Ever since the pandemic strikes the world, the use of healthcare monitoring systems has a massive boost significantly. This paper aims to develop a prototype of a health monitoring device that can be put at a patient home to replace traditional physical checkups at the hospital by using MAX30102 PPG module and Infrared temperature sensor with the objective to derive PPG signal into basic health parameters such as heart rate and oxygen saturation from the patient through MAX30102 and to test the accuracy of those parameters with hospital patient monitor. The experiment is done by comparing each parameter for 30 seconds in both devices using index fingers coming from 13 participants. From the results obtained, although heart rate suffers motion artefact compared to the oxygen saturation, each accuracy is still excellent with 89.2 and 97.6 percent. In conclusion, MAX30102 PPG and ECG module can get initial health reading through the PPG signal and solve the problems mentioned.
format Conference or Workshop Item
author Ahmad, Robiah
Mad Kaidi, Hazilah
Nordin, Muhammad Noor
Ramli, Aizat Faiz
Abu, Mohd. Azlan
Kadase, Yosof
author_facet Ahmad, Robiah
Mad Kaidi, Hazilah
Nordin, Muhammad Noor
Ramli, Aizat Faiz
Abu, Mohd. Azlan
Kadase, Yosof
author_sort Ahmad, Robiah
title Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32
title_short Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32
title_full Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32
title_fullStr Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32
title_full_unstemmed Development of blood oxygen level, heart rate and temperature monitoring system by using ESP32
title_sort development of blood oxygen level, heart rate and temperature monitoring system by using esp32
publishDate 2022
url http://eprints.utm.my/id/eprint/98916/
http://dx.doi.org/10.1109/ICSSA54161.2022.9870943
_version_ 1758578037329231872
score 13.160551