Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications

Ti-based alloys namely, Ti-Ni, has been used as biomedical material due to its superior properties. However, it has been reported recently that nickel is toxic to the human body and thus alternative nickel-free alloys has been rigorously studied. The best candidate materials are Ti-Nb and Ti-Ta whic...

Full description

Saved in:
Bibliographic Details
Main Authors: Hamzah, E., Anuar, Z. Z., Arudi, I. S., Ibrahim, M. K., Bahador, A., Khaatak, A.
Format: Conference or Workshop Item
Published: 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/97993/
http://dx.doi.org/10.1016/j.matpr.2020.04.520
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.97993
record_format eprints
spelling my.utm.979932022-11-14T09:36:44Z http://eprints.utm.my/id/eprint/97993/ Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications Hamzah, E. Anuar, Z. Z. Arudi, I. S. Ibrahim, M. K. Bahador, A. Khaatak, A. TJ Mechanical engineering and machinery Ti-based alloys namely, Ti-Ni, has been used as biomedical material due to its superior properties. However, it has been reported recently that nickel is toxic to the human body and thus alternative nickel-free alloys has been rigorously studied. The best candidate materials are Ti-Nb and Ti-Ta which are known to be biocompatible. These alloys maybe produced either via casting or through powder metallurgy route. Both production and fabrication methods produced dense and porous materials respectively which have different applications in biomedical field. This paper describes the influence of production and fabrication methods on the microstructures and hardness of nickel-free Ti-alloys, namely, Ti-Nb and Ti-Ta alloys with Ti-Ni as a reference alloy. The alloys were produced by three different methods: casting in vacuum induction furnace, compaction of powders followed by microwave sintering and compaction of powders followed by spark plasma sintering. The presence of porosity was analysed on the as cast and sintered samples by Archimedes drainage method while microstructures analysis was done using standard materials characterisation techniques such as optical and electron microscopy as well as X-ray diffractometry. Hardness test was also conducted by Vickers hardness test. It was found that the alloys with different production and fabrication methods give slight variation in the microstructures in terms of grain size and structures, porosity intensities and pore size. As-cast Ti alloys have the lowest amount of porosity and highest hardness values while Ti alloys fabricated by microwave sintering have the highest porosity content with lowest hardness values. 2021 Conference or Workshop Item PeerReviewed Hamzah, E. and Anuar, Z. Z. and Arudi, I. S. and Ibrahim, M. K. and Bahador, A. and Khaatak, A. (2021) Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications. In: 2019 Sustainable and Integrated Engineering International Conference, SIE 2019, 9 - 10 December 2019, Putrajaya, Malaysia. http://dx.doi.org/10.1016/j.matpr.2020.04.520
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TJ Mechanical engineering and machinery
spellingShingle TJ Mechanical engineering and machinery
Hamzah, E.
Anuar, Z. Z.
Arudi, I. S.
Ibrahim, M. K.
Bahador, A.
Khaatak, A.
Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications
description Ti-based alloys namely, Ti-Ni, has been used as biomedical material due to its superior properties. However, it has been reported recently that nickel is toxic to the human body and thus alternative nickel-free alloys has been rigorously studied. The best candidate materials are Ti-Nb and Ti-Ta which are known to be biocompatible. These alloys maybe produced either via casting or through powder metallurgy route. Both production and fabrication methods produced dense and porous materials respectively which have different applications in biomedical field. This paper describes the influence of production and fabrication methods on the microstructures and hardness of nickel-free Ti-alloys, namely, Ti-Nb and Ti-Ta alloys with Ti-Ni as a reference alloy. The alloys were produced by three different methods: casting in vacuum induction furnace, compaction of powders followed by microwave sintering and compaction of powders followed by spark plasma sintering. The presence of porosity was analysed on the as cast and sintered samples by Archimedes drainage method while microstructures analysis was done using standard materials characterisation techniques such as optical and electron microscopy as well as X-ray diffractometry. Hardness test was also conducted by Vickers hardness test. It was found that the alloys with different production and fabrication methods give slight variation in the microstructures in terms of grain size and structures, porosity intensities and pore size. As-cast Ti alloys have the lowest amount of porosity and highest hardness values while Ti alloys fabricated by microwave sintering have the highest porosity content with lowest hardness values.
format Conference or Workshop Item
author Hamzah, E.
Anuar, Z. Z.
Arudi, I. S.
Ibrahim, M. K.
Bahador, A.
Khaatak, A.
author_facet Hamzah, E.
Anuar, Z. Z.
Arudi, I. S.
Ibrahim, M. K.
Bahador, A.
Khaatak, A.
author_sort Hamzah, E.
title Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications
title_short Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications
title_full Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications
title_fullStr Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications
title_full_unstemmed Influence of fabrication methods on the microstructures and hardness of Ti-Ni, Ti-Nb and Ti-Ta for biomedical applications
title_sort influence of fabrication methods on the microstructures and hardness of ti-ni, ti-nb and ti-ta for biomedical applications
publishDate 2021
url http://eprints.utm.my/id/eprint/97993/
http://dx.doi.org/10.1016/j.matpr.2020.04.520
_version_ 1751536132498128896
score 13.18916