Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames

In this study, numerical analysis was used to derive seismic fragility curves for 3-, 6- and 9-story reinforced concrete (RC) frame with inadequate lap splice length and ground soft-story condition. The structural models were subjected to 15 far-field natural earthquake records. The peak ground acce...

Full description

Saved in:
Bibliographic Details
Main Authors: Koon, F. S., Vafaei, M., Alih, S. C.
Format: Conference or Workshop Item
Language:English
Published: 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/97981/1/MohammadrezaVafaei2021_EffectofInadequateLapSpliceLengthontheSeismicFragility.pdf
http://eprints.utm.my/id/eprint/97981/
http://dx.doi.org/10.1088/1755-1315/682/1/012009
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.97981
record_format eprints
spelling my.utm.979812022-11-14T09:27:53Z http://eprints.utm.my/id/eprint/97981/ Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames Koon, F. S. Vafaei, M. Alih, S. C. TA Engineering (General). Civil engineering (General) In this study, numerical analysis was used to derive seismic fragility curves for 3-, 6- and 9-story reinforced concrete (RC) frame with inadequate lap splice length and ground soft-story condition. The structural models were subjected to 15 far-field natural earthquake records. The peak ground acceleration (PGA) of the selected records was scaled in the range of 0.05g to 0.50g with an increment of 0.05g. Incremental dynamic analysis was employed to determine their inter-story drift demand and capacities. The obtained results indicated that the probability of severe damage to the RC frames increased as the number of stories decreased. It was also observed that the RC frames with inadequate lap splice length exhibited significantly higher probability of collapse when compared with RC frames with adequate lap splice length. 2021 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/97981/1/MohammadrezaVafaei2021_EffectofInadequateLapSpliceLengthontheSeismicFragility.pdf Koon, F. S. and Vafaei, M. and Alih, S. C. (2021) Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames. In: 4th National Conference on Wind and Earthquake Engineering, NCWE 2020, 16 - 17 October 2020, Putrajaya, Virtual. http://dx.doi.org/10.1088/1755-1315/682/1/012009 DOI : 10.1109/ACCESS.2021.3105517
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Koon, F. S.
Vafaei, M.
Alih, S. C.
Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames
description In this study, numerical analysis was used to derive seismic fragility curves for 3-, 6- and 9-story reinforced concrete (RC) frame with inadequate lap splice length and ground soft-story condition. The structural models were subjected to 15 far-field natural earthquake records. The peak ground acceleration (PGA) of the selected records was scaled in the range of 0.05g to 0.50g with an increment of 0.05g. Incremental dynamic analysis was employed to determine their inter-story drift demand and capacities. The obtained results indicated that the probability of severe damage to the RC frames increased as the number of stories decreased. It was also observed that the RC frames with inadequate lap splice length exhibited significantly higher probability of collapse when compared with RC frames with adequate lap splice length.
format Conference or Workshop Item
author Koon, F. S.
Vafaei, M.
Alih, S. C.
author_facet Koon, F. S.
Vafaei, M.
Alih, S. C.
author_sort Koon, F. S.
title Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames
title_short Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames
title_full Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames
title_fullStr Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames
title_full_unstemmed Effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames
title_sort effect of inadequate lap splice length on the seismic fragility of ground soft-story reinforced concrete frames
publishDate 2021
url http://eprints.utm.my/id/eprint/97981/1/MohammadrezaVafaei2021_EffectofInadequateLapSpliceLengthontheSeismicFragility.pdf
http://eprints.utm.my/id/eprint/97981/
http://dx.doi.org/10.1088/1755-1315/682/1/012009
_version_ 1751536130779512832
score 13.19449