Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach

Electrical Capacitance Tomography (ECT) is one of the soft field tomography that widely used for the purpose of measurement and monitoring of multiphase flow. Common problem of the soft field tomography is low quality and unstable images in the pipe especially at the center section of the pipe. In t...

Full description

Saved in:
Bibliographic Details
Main Authors: Hisham, Muhammad Faris Aiman, Abdul Wahab, Yasmin, Md. Zain, Zainah, Rahiman, Mohd. Hafiz Fazalul, Leow, Pei Ling, Arsat, Rashidah, Abdul Rahim, Ruzairi, Abu Talip@Yusof, Nurhafizah, Abdul Karim, Rohana, Zakaria, Nor Farizan, Arshad, Nurul Wahidah, Ridzuan Aw, Suzanna, Jamaludin, Juliza
Format: Article
Language:English
Published: Malaysian Society for Computed Tomography & Imaging Technology (MyCT) 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/97419/1/RuzairiAbdulRahim2021_DoesParallelProjectionisSuitable.pdf
http://eprints.utm.my/id/eprint/97419/
http://www.tssa.my/index.php/jtssa/article/view/154
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.97419
record_format eprints
spelling my.utm.974192022-10-10T07:25:46Z http://eprints.utm.my/id/eprint/97419/ Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach Hisham, Muhammad Faris Aiman Abdul Wahab, Yasmin Md. Zain, Zainah Rahiman, Mohd. Hafiz Fazalul Leow, Pei Ling Arsat, Rashidah Abdul Rahim, Ruzairi Abu Talip@Yusof, Nurhafizah Abdul Karim, Rohana Zakaria, Nor Farizan Arshad, Nurul Wahidah Ridzuan Aw, Suzanna Jamaludin, Juliza TK Electrical engineering. Electronics Nuclear engineering Electrical Capacitance Tomography (ECT) is one of the soft field tomography that widely used for the purpose of measurement and monitoring of multiphase flow. Common problem of the soft field tomography is low quality and unstable images in the pipe especially at the center section of the pipe. In this paper, an ECT system with a comparison between common approach and a parallel approach is presented. Simulation in 2 dimensions with 16-electrode is carried out to observe a potential projection. The COMSOL Multiphysics software is used to investigate the state and response of the electric field with this approach by exporting data with 128x128 pixels. Air bubbles as a phantom in the oil medium have been tested and analyzed. Linear Back-Projection Algorithm (LBP) is implemented using MATLAB software to obtain a tomogram. A Multi Scale Structural Similarity, MSSIM was applied to compare both approaches. Consequently, the resolution and quality of the pictures in the pipes can be distinguished. However, a further investigation is needed to improve the parallel approach for ECT system. Malaysian Society for Computed Tomography & Imaging Technology (MyCT) 2021-03 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/97419/1/RuzairiAbdulRahim2021_DoesParallelProjectionisSuitable.pdf Hisham, Muhammad Faris Aiman and Abdul Wahab, Yasmin and Md. Zain, Zainah and Rahiman, Mohd. Hafiz Fazalul and Leow, Pei Ling and Arsat, Rashidah and Abdul Rahim, Ruzairi and Abu Talip@Yusof, Nurhafizah and Abdul Karim, Rohana and Zakaria, Nor Farizan and Arshad, Nurul Wahidah and Ridzuan Aw, Suzanna and Jamaludin, Juliza (2021) Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach. Journal of Tomography System & Sensors Application, 4 (1). pp. 85-92. ISSN 2636-9133 http://www.tssa.my/index.php/jtssa/article/view/154 NA
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Hisham, Muhammad Faris Aiman
Abdul Wahab, Yasmin
Md. Zain, Zainah
Rahiman, Mohd. Hafiz Fazalul
Leow, Pei Ling
Arsat, Rashidah
Abdul Rahim, Ruzairi
Abu Talip@Yusof, Nurhafizah
Abdul Karim, Rohana
Zakaria, Nor Farizan
Arshad, Nurul Wahidah
Ridzuan Aw, Suzanna
Jamaludin, Juliza
Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach
description Electrical Capacitance Tomography (ECT) is one of the soft field tomography that widely used for the purpose of measurement and monitoring of multiphase flow. Common problem of the soft field tomography is low quality and unstable images in the pipe especially at the center section of the pipe. In this paper, an ECT system with a comparison between common approach and a parallel approach is presented. Simulation in 2 dimensions with 16-electrode is carried out to observe a potential projection. The COMSOL Multiphysics software is used to investigate the state and response of the electric field with this approach by exporting data with 128x128 pixels. Air bubbles as a phantom in the oil medium have been tested and analyzed. Linear Back-Projection Algorithm (LBP) is implemented using MATLAB software to obtain a tomogram. A Multi Scale Structural Similarity, MSSIM was applied to compare both approaches. Consequently, the resolution and quality of the pictures in the pipes can be distinguished. However, a further investigation is needed to improve the parallel approach for ECT system.
format Article
author Hisham, Muhammad Faris Aiman
Abdul Wahab, Yasmin
Md. Zain, Zainah
Rahiman, Mohd. Hafiz Fazalul
Leow, Pei Ling
Arsat, Rashidah
Abdul Rahim, Ruzairi
Abu Talip@Yusof, Nurhafizah
Abdul Karim, Rohana
Zakaria, Nor Farizan
Arshad, Nurul Wahidah
Ridzuan Aw, Suzanna
Jamaludin, Juliza
author_facet Hisham, Muhammad Faris Aiman
Abdul Wahab, Yasmin
Md. Zain, Zainah
Rahiman, Mohd. Hafiz Fazalul
Leow, Pei Ling
Arsat, Rashidah
Abdul Rahim, Ruzairi
Abu Talip@Yusof, Nurhafizah
Abdul Karim, Rohana
Zakaria, Nor Farizan
Arshad, Nurul Wahidah
Ridzuan Aw, Suzanna
Jamaludin, Juliza
author_sort Hisham, Muhammad Faris Aiman
title Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach
title_short Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach
title_full Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach
title_fullStr Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach
title_full_unstemmed Does parallel projection is suitable in electrical capacitance tomography? -A comparison with common approach
title_sort does parallel projection is suitable in electrical capacitance tomography? -a comparison with common approach
publisher Malaysian Society for Computed Tomography & Imaging Technology (MyCT)
publishDate 2021
url http://eprints.utm.my/id/eprint/97419/1/RuzairiAbdulRahim2021_DoesParallelProjectionisSuitable.pdf
http://eprints.utm.my/id/eprint/97419/
http://www.tssa.my/index.php/jtssa/article/view/154
_version_ 1748180456826732544
score 13.160551