Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor

The performance of a biosensor sensing layer is mostly determined by the immobilization method and the materials used to immobilize the enzyme. In this work, the performances of four types of glucose oxidase immobilization materials based on poly(vinyl alcohol) (PVA) for peroxide-based glucose biose...

Full description

Saved in:
Bibliographic Details
Main Author: Wong, Fui Ling
Format: Thesis
Language:English
Published: 2008
Subjects:
Online Access:http://eprints.utm.my/id/eprint/9648/1/WongFuiLingMFKT2008.pdf
http://eprints.utm.my/id/eprint/9648/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:1084
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.9648
record_format eprints
spelling my.utm.96482018-10-14T07:19:59Z http://eprints.utm.my/id/eprint/9648/ Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor Wong, Fui Ling TP Chemical technology The performance of a biosensor sensing layer is mostly determined by the immobilization method and the materials used to immobilize the enzyme. In this work, the performances of four types of glucose oxidase immobilization materials based on poly(vinyl alcohol) (PVA) for peroxide-based glucose biosensor were compared. The matrices of interest were glutaraldehyde cross-linked PVA (GAPVA), freeze-thawed PVA cryogel (FTPVA), tetramethoxysilane sol-gel-PVA hybrid material (TMOS-PVA), and alumina sol-gel-PVA hybrid material (Al-PVA). Only GAPVA showed short period of enzyme leaking and high value of Km app. However, its sensitivity was poor. With the same enzyme loading, the other three types of membranes showed good sensitivity and stability. FTPVA and TMOSPVA, which showed satisfactory sensitivity and adequate value of Km app were quite promising as the support materials for immobilizing glucose oxidase (GOD). The enzyme leakage of FTPVA which had shown highest leaking was improved by reducing the enzyme loading. Even though peroxide-based sensor is very simple and easy to construct, it suffers from electrochemical interferences from common electroactive species present in blood such as acetaminophen. Hence, a photocured poly(hydroxyethyl methacrylate) (pHEMA) layer was investigated as a potential permselective inner membrane to eliminate the interferences based on size exclusion. PHEMA membrane with the cross-linking ratio of 0.043 was found to be able to achieve a selectivity of 10, while maintaining an acceptable degree of hydrogen peroxide response. In a two-layer glucose biosensor, where the FTPVA-GOD and cross-linked pHEMA were combined, acetaminophen and ascorbic acid at 0.2 mM were eliminated completely. 0.2 mM uric acid still gave a bias of approximately 6.6% relative to 5 mM glucose. Overall, the partial glucose biosensor showed promising performance. 2008-07 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/9648/1/WongFuiLingMFKT2008.pdf Wong, Fui Ling (2008) Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor. Masters thesis, Universiti Teknologi Malaysia, Faculty of Chemical and Natural Resources Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:1084
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Wong, Fui Ling
Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor
description The performance of a biosensor sensing layer is mostly determined by the immobilization method and the materials used to immobilize the enzyme. In this work, the performances of four types of glucose oxidase immobilization materials based on poly(vinyl alcohol) (PVA) for peroxide-based glucose biosensor were compared. The matrices of interest were glutaraldehyde cross-linked PVA (GAPVA), freeze-thawed PVA cryogel (FTPVA), tetramethoxysilane sol-gel-PVA hybrid material (TMOS-PVA), and alumina sol-gel-PVA hybrid material (Al-PVA). Only GAPVA showed short period of enzyme leaking and high value of Km app. However, its sensitivity was poor. With the same enzyme loading, the other three types of membranes showed good sensitivity and stability. FTPVA and TMOSPVA, which showed satisfactory sensitivity and adequate value of Km app were quite promising as the support materials for immobilizing glucose oxidase (GOD). The enzyme leakage of FTPVA which had shown highest leaking was improved by reducing the enzyme loading. Even though peroxide-based sensor is very simple and easy to construct, it suffers from electrochemical interferences from common electroactive species present in blood such as acetaminophen. Hence, a photocured poly(hydroxyethyl methacrylate) (pHEMA) layer was investigated as a potential permselective inner membrane to eliminate the interferences based on size exclusion. PHEMA membrane with the cross-linking ratio of 0.043 was found to be able to achieve a selectivity of 10, while maintaining an acceptable degree of hydrogen peroxide response. In a two-layer glucose biosensor, where the FTPVA-GOD and cross-linked pHEMA were combined, acetaminophen and ascorbic acid at 0.2 mM were eliminated completely. 0.2 mM uric acid still gave a bias of approximately 6.6% relative to 5 mM glucose. Overall, the partial glucose biosensor showed promising performance.
format Thesis
author Wong, Fui Ling
author_facet Wong, Fui Ling
author_sort Wong, Fui Ling
title Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor
title_short Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor
title_full Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor
title_fullStr Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor
title_full_unstemmed Enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor
title_sort enzyme immobilization and permselectivity analysis of an interference free peroxide based glucose biosensor
publishDate 2008
url http://eprints.utm.my/id/eprint/9648/1/WongFuiLingMFKT2008.pdf
http://eprints.utm.my/id/eprint/9648/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:1084
_version_ 1643645215620202496
score 13.160551