Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process

Hollow fiber membrane contactor (HFMC) has been widely studied for gas separation process due to its process intensification capability of combining conventional contactors with membrane technology. In the area of modeling and simulation of HFMC, the development of mathematical model for non-ideal c...

Full description

Saved in:
Bibliographic Details
Main Authors: Ng, E. L. H., Lau, K. K., Lau, W. J., Ahmad, Faizan
Format: Article
Published: Elsevier B.V. 2021
Subjects:
Online Access:http://eprints.utm.my/id/eprint/95704/
http://dx.doi.org/10.1016/j.jiec.2021.08.028
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.95704
record_format eprints
spelling my.utm.957042022-05-31T13:17:57Z http://eprints.utm.my/id/eprint/95704/ Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process Ng, E. L. H. Lau, K. K. Lau, W. J. Ahmad, Faizan Q Science (General) TP Chemical technology Hollow fiber membrane contactor (HFMC) has been widely studied for gas separation process due to its process intensification capability of combining conventional contactors with membrane technology. In the area of modeling and simulation of HFMC, the development of mathematical model for non-ideal conditions, that is incorporated into process design is key to accurately reflect actual industrial gas separation process. This article aims to review the modelling and simulation techniques, the capabilities and the limitations of different mathematical models in predicting gas separation performance in HFMC for both laboratory analysis and industrial applications. The approach of incorporating the HFMC models into gas separation system and the current progress of process simulation works to develop industrial scale gas separation process will be highlighted. Future works and challenges towards developing comprehensive model in HFMC for industrial gas separation process would also be presented to portray the potential of modelling and simulation in designing and optimizing the HFMC system. Elsevier B.V. 2021-12-25 Article PeerReviewed Ng, E. L. H. and Lau, K. K. and Lau, W. J. and Ahmad, Faizan (2021) Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process. Journal of Industrial and Engineering Chemistry, 104 . pp. 231-257. ISSN 1226-086X http://dx.doi.org/10.1016/j.jiec.2021.08.028 DOI:10.1016/j.jiec.2021.08.028
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic Q Science (General)
TP Chemical technology
spellingShingle Q Science (General)
TP Chemical technology
Ng, E. L. H.
Lau, K. K.
Lau, W. J.
Ahmad, Faizan
Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
description Hollow fiber membrane contactor (HFMC) has been widely studied for gas separation process due to its process intensification capability of combining conventional contactors with membrane technology. In the area of modeling and simulation of HFMC, the development of mathematical model for non-ideal conditions, that is incorporated into process design is key to accurately reflect actual industrial gas separation process. This article aims to review the modelling and simulation techniques, the capabilities and the limitations of different mathematical models in predicting gas separation performance in HFMC for both laboratory analysis and industrial applications. The approach of incorporating the HFMC models into gas separation system and the current progress of process simulation works to develop industrial scale gas separation process will be highlighted. Future works and challenges towards developing comprehensive model in HFMC for industrial gas separation process would also be presented to portray the potential of modelling and simulation in designing and optimizing the HFMC system.
format Article
author Ng, E. L. H.
Lau, K. K.
Lau, W. J.
Ahmad, Faizan
author_facet Ng, E. L. H.
Lau, K. K.
Lau, W. J.
Ahmad, Faizan
author_sort Ng, E. L. H.
title Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_short Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_full Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_fullStr Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_full_unstemmed Holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
title_sort holistic review on the recent development in mathematical modelling and process simulation of hollow fiber membrane contactor for gas separation process
publisher Elsevier B.V.
publishDate 2021
url http://eprints.utm.my/id/eprint/95704/
http://dx.doi.org/10.1016/j.jiec.2021.08.028
_version_ 1735386836978630656
score 13.214268