Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester
Resistive leakage current based condition assessment of metal oxide surge arrester (MOSA) is one of the most extensively employed technique to monitor its degradation. An extraction method is customarily required to extract the resistive component from the total leakage current. The existing methods...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science
2020
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/93742/1/AmirHesamKhavari2020_Circuit-BasedMethodforExtracting.pdf http://eprints.utm.my/id/eprint/93742/ http://dx.doi.org/10.11591/eei.v9i6.2258 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.93742 |
---|---|
record_format |
eprints |
spelling |
my.utm.937422021-12-31T08:48:44Z http://eprints.utm.my/id/eprint/93742/ Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester Khavari, Amir Hesam Munir, Abdullah Abdul Malek, Zulkurnain TK Electrical engineering. Electronics Nuclear engineering Resistive leakage current based condition assessment of metal oxide surge arrester (MOSA) is one of the most extensively employed technique to monitor its degradation. An extraction method is customarily required to extract the resistive component from the total leakage current. The existing methods to extract the resistive current are complex and less accurate. Therefore, this paper describes a simple and accurate circuit-based method to extract the resistive current using equivalent model and measured leakage current of the arrester. The accuracy of the proposed method is validated through experimental results on ABB’s 120kV surge arrester, EMTP and QuickField software simulations. The performance of the method is also analyzed and verified experimentally on 72kV,180kV, and 240kV rated ABB’s surge arresters. The obtained results of resistive leakage current have shown the maximum error of 0.001%. Simple and easier computational steps with higher accuracy are the key benefits of the proposed technique. Institute of Advanced Engineering and Science 2020-12 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/93742/1/AmirHesamKhavari2020_Circuit-BasedMethodforExtracting.pdf Khavari, Amir Hesam and Munir, Abdullah and Abdul Malek, Zulkurnain (2020) Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester. Bulletin of Electrical Engineering and Informatics, 9 (6). pp. 2213-2221. ISSN 2089-3191 http://dx.doi.org/10.11591/eei.v9i6.2258 DOI:10.11591/eei.v9i6.2258 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Khavari, Amir Hesam Munir, Abdullah Abdul Malek, Zulkurnain Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester |
description |
Resistive leakage current based condition assessment of metal oxide surge arrester (MOSA) is one of the most extensively employed technique to monitor its degradation. An extraction method is customarily required to extract the resistive component from the total leakage current. The existing methods to extract the resistive current are complex and less accurate. Therefore, this paper describes a simple and accurate circuit-based method to extract the resistive current using equivalent model and measured leakage current of the arrester. The accuracy of the proposed method is validated through experimental results on ABB’s 120kV surge arrester, EMTP and QuickField software simulations. The performance of the method is also analyzed and verified experimentally on 72kV,180kV, and 240kV rated ABB’s surge arresters. The obtained results of resistive leakage current have shown the maximum error of 0.001%. Simple and easier computational steps with higher accuracy are the key benefits of the proposed technique. |
format |
Article |
author |
Khavari, Amir Hesam Munir, Abdullah Abdul Malek, Zulkurnain |
author_facet |
Khavari, Amir Hesam Munir, Abdullah Abdul Malek, Zulkurnain |
author_sort |
Khavari, Amir Hesam |
title |
Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester |
title_short |
Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester |
title_full |
Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester |
title_fullStr |
Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester |
title_full_unstemmed |
Circuit-based method for extracting the resistive leakage current of metal oxide surge arrester |
title_sort |
circuit-based method for extracting the resistive leakage current of metal oxide surge arrester |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2020 |
url |
http://eprints.utm.my/id/eprint/93742/1/AmirHesamKhavari2020_Circuit-BasedMethodforExtracting.pdf http://eprints.utm.my/id/eprint/93742/ http://dx.doi.org/10.11591/eei.v9i6.2258 |
_version_ |
1720980118444179456 |
score |
13.209306 |