Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections

A test program was considered to clarify the cyclic characteristics of eight full-scale unstiffened extended end-plates with variable parameters and one SidePlate moment connection. All specimens were subjected to 2010 AISC seismic provision loading protocol where flexural strengths were identified...

Full description

Saved in:
Bibliographic Details
Main Authors: Faridmehr, Iman, Md. Tahir, Mamood, Osman, Mohd. Hanim, Azimi, Mohammadamin
Format: Article
Published: Korean Society of Steel Construction 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/93389/
http://dx.doi.org/10.1007/s13296-019-00290-8
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.93389
record_format eprints
spelling my.utm.933892021-11-30T08:28:50Z http://eprints.utm.my/id/eprint/93389/ Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections Faridmehr, Iman Md. Tahir, Mamood Osman, Mohd. Hanim Azimi, Mohammadamin T Technology (General) A test program was considered to clarify the cyclic characteristics of eight full-scale unstiffened extended end-plates with variable parameters and one SidePlate moment connection. All specimens were subjected to 2010 AISC seismic provision loading protocol where flexural strengths were identified at each interstorey drift angle. The results showed that all unstiffened extended end-plate failed to develop full inelastic capacity of connected beams and plastic hinges mainly appeared in the connection’s components. On the other hand, the SidePlate moment connection had the capacity to develop adequate interstorey drift angles up to 0.06 rad, indicating that this type of connection possesses sufficient stiffness and strength to be classified as a rigid and full-strength connection. The results also showed that SidePlate possesses considerably more energy dissipation capacity and an equivalent hysteretic damping ratio compared to unstiffened extended end-plate specimens, especially at higher interstorey drift angles. Korean Society of Steel Construction 2020 Article PeerReviewed Faridmehr, Iman and Md. Tahir, Mamood and Osman, Mohd. Hanim and Azimi, Mohammadamin (2020) Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections. International Journal of Steel Structures, 20 (2). pp. 365-385. ISSN 1598-2351 http://dx.doi.org/10.1007/s13296-019-00290-8
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
spellingShingle T Technology (General)
Faridmehr, Iman
Md. Tahir, Mamood
Osman, Mohd. Hanim
Azimi, Mohammadamin
Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections
description A test program was considered to clarify the cyclic characteristics of eight full-scale unstiffened extended end-plates with variable parameters and one SidePlate moment connection. All specimens were subjected to 2010 AISC seismic provision loading protocol where flexural strengths were identified at each interstorey drift angle. The results showed that all unstiffened extended end-plate failed to develop full inelastic capacity of connected beams and plastic hinges mainly appeared in the connection’s components. On the other hand, the SidePlate moment connection had the capacity to develop adequate interstorey drift angles up to 0.06 rad, indicating that this type of connection possesses sufficient stiffness and strength to be classified as a rigid and full-strength connection. The results also showed that SidePlate possesses considerably more energy dissipation capacity and an equivalent hysteretic damping ratio compared to unstiffened extended end-plate specimens, especially at higher interstorey drift angles.
format Article
author Faridmehr, Iman
Md. Tahir, Mamood
Osman, Mohd. Hanim
Azimi, Mohammadamin
author_facet Faridmehr, Iman
Md. Tahir, Mamood
Osman, Mohd. Hanim
Azimi, Mohammadamin
author_sort Faridmehr, Iman
title Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections
title_short Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections
title_full Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections
title_fullStr Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections
title_full_unstemmed Cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections
title_sort cyclic behaviour of fully-rigid and semi-rigid steel beam-to-column connections
publisher Korean Society of Steel Construction
publishDate 2020
url http://eprints.utm.my/id/eprint/93389/
http://dx.doi.org/10.1007/s13296-019-00290-8
_version_ 1718926060980011008
score 13.18916