Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution

A new crystalliser to concentrate lysozyme aqueous solution through freeze concentration was designed in this study to overcome the shortcomings of the currently available methods in concentrating protein. A new compatible, simple, reliable and low maintenance design was developed in this study base...

Full description

Saved in:
Bibliographic Details
Main Author: Yahya, Norshafika
Format: Thesis
Language:English
Published: 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/92405/1/NorShafikaPSChE2020.pdf.pdf
http://eprints.utm.my/id/eprint/92405/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:138775
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.92405
record_format eprints
spelling my.utm.924052021-09-28T07:34:02Z http://eprints.utm.my/id/eprint/92405/ Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution Yahya, Norshafika TP Chemical technology A new crystalliser to concentrate lysozyme aqueous solution through freeze concentration was designed in this study to overcome the shortcomings of the currently available methods in concentrating protein. A new compatible, simple, reliable and low maintenance design was developed in this study based on progressive freeze concentration principles called multiple probe cryo-concentration system (MPCC). Progressive freeze concentration process is a process which rejects all impurities or solute by generating ice crystal lattice from the mother liquor, thus the remaining solution is more concentrated. The aim of this research is to observe the possibility of the new design system in producing high concentration lysozyme aqueous solution according to the four-effect parametric condition which includes coolant temperature, stirrer speed, operation time and initial concentration. The complete design of MPCC system consists of a solution tank with outer tubular cooling jacket and insulator, containing the protein solution and the cooled multiple probes immersed in it. The concentration process began when the temperature of the lysozyme aqueous solution dropped until the ice crystal formed on the wall of the probe while assisted by the stirrer. The concentrated protein solution was then separated from the ice crystal layer formed and collected as product. In order to evaluate the capability of the design, effective partition constant (K), solute yield of lysozyme (Y), concentration index (CI) and average ice growth rate (?ice) were analysed using UV-Vis spectrophotometer to determine the solute concentration. The findings revealed that coolant temperature at -12 °C, stirrer speed at 350 rpm, operation time at 40 minutes and initial concentration at 10 mg/ml gave the best result of K, Y and Cl and ?ice. Meanwhile, the determination of optimum condition by response surface methodology indicated that coolant temperature is the most significant parameter followed by stirrer speed and operation time but initial concentration was found to be not significant in affecting the process for both responses of K-value and Y. A thermodynamic prediction model was also built and its validity for ice crystal growth rate prediction was found to be adequately accurate compared to the actual experimental result based on the error analysis obtaining R-squared of 0.98 and absolute average relative deviation of 8.08 %. The heat transfer analysis discovered that the overall heat transfer coefficient, U? and heat remover, Q are quite similar for stirrer speed and operation time where increased stirrer speed and lower operation time resulted in lower U? and Q while increased initial concentration would increase the U? and Q. Despite, U? and Q are slightly different and contradict with each other when coolant temperature was increased where U? would increase but Q was decreased. The results from the analysis and investigation shed light on the theory behind the concentration method of protein using freezing method with the newly designed cryo-concentration device, which has never been investigated, tested and discussed specifically for protein concentration. 2020 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/92405/1/NorShafikaPSChE2020.pdf.pdf Yahya, Norshafika (2020) Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution. PhD thesis, Universiti Teknologi Malaysia. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:138775
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Yahya, Norshafika
Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution
description A new crystalliser to concentrate lysozyme aqueous solution through freeze concentration was designed in this study to overcome the shortcomings of the currently available methods in concentrating protein. A new compatible, simple, reliable and low maintenance design was developed in this study based on progressive freeze concentration principles called multiple probe cryo-concentration system (MPCC). Progressive freeze concentration process is a process which rejects all impurities or solute by generating ice crystal lattice from the mother liquor, thus the remaining solution is more concentrated. The aim of this research is to observe the possibility of the new design system in producing high concentration lysozyme aqueous solution according to the four-effect parametric condition which includes coolant temperature, stirrer speed, operation time and initial concentration. The complete design of MPCC system consists of a solution tank with outer tubular cooling jacket and insulator, containing the protein solution and the cooled multiple probes immersed in it. The concentration process began when the temperature of the lysozyme aqueous solution dropped until the ice crystal formed on the wall of the probe while assisted by the stirrer. The concentrated protein solution was then separated from the ice crystal layer formed and collected as product. In order to evaluate the capability of the design, effective partition constant (K), solute yield of lysozyme (Y), concentration index (CI) and average ice growth rate (?ice) were analysed using UV-Vis spectrophotometer to determine the solute concentration. The findings revealed that coolant temperature at -12 °C, stirrer speed at 350 rpm, operation time at 40 minutes and initial concentration at 10 mg/ml gave the best result of K, Y and Cl and ?ice. Meanwhile, the determination of optimum condition by response surface methodology indicated that coolant temperature is the most significant parameter followed by stirrer speed and operation time but initial concentration was found to be not significant in affecting the process for both responses of K-value and Y. A thermodynamic prediction model was also built and its validity for ice crystal growth rate prediction was found to be adequately accurate compared to the actual experimental result based on the error analysis obtaining R-squared of 0.98 and absolute average relative deviation of 8.08 %. The heat transfer analysis discovered that the overall heat transfer coefficient, U? and heat remover, Q are quite similar for stirrer speed and operation time where increased stirrer speed and lower operation time resulted in lower U? and Q while increased initial concentration would increase the U? and Q. Despite, U? and Q are slightly different and contradict with each other when coolant temperature was increased where U? would increase but Q was decreased. The results from the analysis and investigation shed light on the theory behind the concentration method of protein using freezing method with the newly designed cryo-concentration device, which has never been investigated, tested and discussed specifically for protein concentration.
format Thesis
author Yahya, Norshafika
author_facet Yahya, Norshafika
author_sort Yahya, Norshafika
title Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution
title_short Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution
title_full Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution
title_fullStr Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution
title_full_unstemmed Development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution
title_sort development of multiple probe cryo-concentration system for progressive freeze concentration of lysozyme aqueous solution
publishDate 2020
url http://eprints.utm.my/id/eprint/92405/1/NorShafikaPSChE2020.pdf.pdf
http://eprints.utm.my/id/eprint/92405/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:138775
_version_ 1712285089867497472
score 13.160551