Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process

Sintering Laser Melting is recently used for manufacturing industry to produce biomedical parts. The design properties that affected the topography of porous titanium for a biomedical implant that closely suit to human cortical bone fabricated via additive manufacturing is still limited. The aim of...

Full description

Saved in:
Bibliographic Details
Main Authors: Sadali, M. F., Hassan, M. Z., Ahmad, N. H., Yahya, H., Nor, A. F. M.
Format: Article
Published: Microscopy Society of Malaysia 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/91575/
https://malaysianjournalofmicroscopy.org/ojs/index.php/mjm/article/view/383
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.91575
record_format eprints
spelling my.utm.915752021-07-04T01:55:59Z http://eprints.utm.my/id/eprint/91575/ Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process Sadali, M. F. Hassan, M. Z. Ahmad, N. H. Yahya, H. Nor, A. F. M. T Technology (General) Sintering Laser Melting is recently used for manufacturing industry to produce biomedical parts. The design properties that affected the topography of porous titanium for a biomedical implant that closely suit to human cortical bone fabricated via additive manufacturing is still limited. The aim of this work was to study the effect of hatching distance on the morphology and surface microscopy of Ti6Al4V using sintering laser melting (SLM). The square cube with the dimension of 10x10x10 mm fabricated at three different levels (0.11, 0.12 and 0.13 mm) of hatching distances. Here, the volumetric energy density parameter, including scanning speed, thickness layer, and laser power were fixed. The result showed that the surface morphology of the parts, consisting of balling effect and microcrack, had the most significant effect on microstructure. In addition, the average roughness on the side surfaces are 4.4 µm and 4.8 µm respectively, which is well suit for the bone-implant application in biomedical product. Microscopy Society of Malaysia 2019 Article PeerReviewed Sadali, M. F. and Hassan, M. Z. and Ahmad, N. H. and Yahya, H. and Nor, A. F. M. (2019) Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process. Malaysian Journal of Microscopy, 15 (1). pp. 72-82. ISSN 1823-7010 https://malaysianjournalofmicroscopy.org/ojs/index.php/mjm/article/view/383
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
spellingShingle T Technology (General)
Sadali, M. F.
Hassan, M. Z.
Ahmad, N. H.
Yahya, H.
Nor, A. F. M.
Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process
description Sintering Laser Melting is recently used for manufacturing industry to produce biomedical parts. The design properties that affected the topography of porous titanium for a biomedical implant that closely suit to human cortical bone fabricated via additive manufacturing is still limited. The aim of this work was to study the effect of hatching distance on the morphology and surface microscopy of Ti6Al4V using sintering laser melting (SLM). The square cube with the dimension of 10x10x10 mm fabricated at three different levels (0.11, 0.12 and 0.13 mm) of hatching distances. Here, the volumetric energy density parameter, including scanning speed, thickness layer, and laser power were fixed. The result showed that the surface morphology of the parts, consisting of balling effect and microcrack, had the most significant effect on microstructure. In addition, the average roughness on the side surfaces are 4.4 µm and 4.8 µm respectively, which is well suit for the bone-implant application in biomedical product.
format Article
author Sadali, M. F.
Hassan, M. Z.
Ahmad, N. H.
Yahya, H.
Nor, A. F. M.
author_facet Sadali, M. F.
Hassan, M. Z.
Ahmad, N. H.
Yahya, H.
Nor, A. F. M.
author_sort Sadali, M. F.
title Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process
title_short Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process
title_full Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process
title_fullStr Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process
title_full_unstemmed Effect of hatching distance on surface morphology and surface roughness of the TI6AL4V for biomedical implant using SLM process
title_sort effect of hatching distance on surface morphology and surface roughness of the ti6al4v for biomedical implant using slm process
publisher Microscopy Society of Malaysia
publishDate 2019
url http://eprints.utm.my/id/eprint/91575/
https://malaysianjournalofmicroscopy.org/ojs/index.php/mjm/article/view/383
_version_ 1705056732595617792
score 13.214268