Dielectrophoresis-based microfluidic device for separation of potential cancer cells
Cancer is a leading cause of death that adversely affects all ages and genders around the world. There is a range of approaches such as CT scanning and mammography to diagnose cancer. Although the current method has many benefits, most of it share similar drawbacks as the result of detection takes l...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Published: |
Institute of Advanced Engineering and Science
2020
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/91542/ http://dx.doi.org/10.11591/eei.v9i6.2224 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.91542 |
---|---|
record_format |
eprints |
spelling |
my.utm.915422021-06-30T12:17:46Z http://eprints.utm.my/id/eprint/91542/ Dielectrophoresis-based microfluidic device for separation of potential cancer cells Mohamad Narji, Nur Fatien Najwa Ahmad, Mohd. Ridzuan TK Electrical engineering. Electronics Nuclear engineering Cancer is a leading cause of death that adversely affects all ages and genders around the world. There is a range of approaches such as CT scanning and mammography to diagnose cancer. Although the current method has many benefits, most of it share similar drawbacks as the result of detection takes long time and can lead to over diagnosis. Dielectrophoresis (DEP) is a method that can be used to obtain the cell electrical properties such as capacitance, conductivity, and permittivity. A device was designed in this study using a pair of electrodes and main channel with two inlets and two outlets. COMSOL software is adopted to analyze channel particle flow. Results show the configuration of microfluidic device and its dimensions. For potential application, DEP may be used as a non-invasive technique to distinguish normal cell from cancerous cell, which can lead to early detection as it offers a real-time warning. The simulations reveal that the electrodes captured the particles successfully and sorted them within specific time. The chance of cell capture and the ability of the electrodes to sort the cells is around 80%. In addition, an ideal design of the microfluidic chip was established, incorporating the cell and dielectric properties. Institute of Advanced Engineering and Science 2020-12 Article PeerReviewed Mohamad Narji, Nur Fatien Najwa and Ahmad, Mohd. Ridzuan (2020) Dielectrophoresis-based microfluidic device for separation of potential cancer cells. Bulletin of Electrical Engineering and Informatics, 9 (6). pp. 2270-2277. ISSN 2089-3191 http://dx.doi.org/10.11591/eei.v9i6.2224 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Mohamad Narji, Nur Fatien Najwa Ahmad, Mohd. Ridzuan Dielectrophoresis-based microfluidic device for separation of potential cancer cells |
description |
Cancer is a leading cause of death that adversely affects all ages and genders around the world. There is a range of approaches such as CT scanning and mammography to diagnose cancer. Although the current method has many benefits, most of it share similar drawbacks as the result of detection takes long time and can lead to over diagnosis. Dielectrophoresis (DEP) is a method that can be used to obtain the cell electrical properties such as capacitance, conductivity, and permittivity. A device was designed in this study using a pair of electrodes and main channel with two inlets and two outlets. COMSOL software is adopted to analyze channel particle flow. Results show the configuration of microfluidic device and its dimensions. For potential application, DEP may be used as a non-invasive technique to distinguish normal cell from cancerous cell, which can lead to early detection as it offers a real-time warning. The simulations reveal that the electrodes captured the particles successfully and sorted them within specific time. The chance of cell capture and the ability of the electrodes to sort the cells is around 80%. In addition, an ideal design of the microfluidic chip was established, incorporating the cell and dielectric properties. |
format |
Article |
author |
Mohamad Narji, Nur Fatien Najwa Ahmad, Mohd. Ridzuan |
author_facet |
Mohamad Narji, Nur Fatien Najwa Ahmad, Mohd. Ridzuan |
author_sort |
Mohamad Narji, Nur Fatien Najwa |
title |
Dielectrophoresis-based microfluidic device for separation of potential cancer cells |
title_short |
Dielectrophoresis-based microfluidic device for separation of potential cancer cells |
title_full |
Dielectrophoresis-based microfluidic device for separation of potential cancer cells |
title_fullStr |
Dielectrophoresis-based microfluidic device for separation of potential cancer cells |
title_full_unstemmed |
Dielectrophoresis-based microfluidic device for separation of potential cancer cells |
title_sort |
dielectrophoresis-based microfluidic device for separation of potential cancer cells |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2020 |
url |
http://eprints.utm.my/id/eprint/91542/ http://dx.doi.org/10.11591/eei.v9i6.2224 |
_version_ |
1705056728636194816 |
score |
13.209306 |