Capacitance-based microfluidic device for early ammonia detection in river water
This paper proposes a design of a microfluidic device for early detection of ammonia in river water based on capacitance measurement. A microfluidic device is designed and simulated to measure the content of ammonia in river water by using the COMSOL finite element analysis (FEA) software. This pape...
Saved in:
Main Authors: | , |
---|---|
Format: | Article |
Language: | English |
Published: |
Institute of Advanced Engineering and Science
2020
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/91500/1/MohdRidzuanAhmad2020_Capacitance-BasedMicrofluidicDeviceforEarlyAmmoniaDetection.pdf http://eprints.utm.my/id/eprint/91500/ http://dx.doi.org/10.11591/ijeecs.v20.i2.pp761-767 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.91500 |
---|---|
record_format |
eprints |
spelling |
my.utm.915002021-06-30T12:17:23Z http://eprints.utm.my/id/eprint/91500/ Capacitance-based microfluidic device for early ammonia detection in river water Ramli, Muhammad Muhaimin Ahmad, Mohd. Ridzuan TK Electrical engineering. Electronics Nuclear engineering This paper proposes a design of a microfluidic device for early detection of ammonia in river water based on capacitance measurement. A microfluidic device is designed and simulated to measure the content of ammonia in river water by using the COMSOL finite element analysis (FEA) software. This paper describes the system in detail from the conceptual idea to the hardware implementation. The microfluidic device works by inserting the sample of water into the device to be tested. A pair of electrodes is connected to the electrical circuit and the value of the capacitance of the water sample is measured. The tested samples are normal river water and contaminated river water which have ammonia in it. Several investigations have been done via the simulation, i.e. the size of the electrode, the difference in water flow gap, the distance between the electrode, speed of the water and the capacitance of the water. The results show that the proposed microfluidic design is capable to detect ammonia inside river water under 2 ppm concentration. Institute of Advanced Engineering and Science 2020-11 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/91500/1/MohdRidzuanAhmad2020_Capacitance-BasedMicrofluidicDeviceforEarlyAmmoniaDetection.pdf Ramli, Muhammad Muhaimin and Ahmad, Mohd. Ridzuan (2020) Capacitance-based microfluidic device for early ammonia detection in river water. Indonesian Journal of Electrical Engineering and Computer Science, 20 (2). pp. 761-767. ISSN 2502-4752 http://dx.doi.org/10.11591/ijeecs.v20.i2.pp761-767 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Ramli, Muhammad Muhaimin Ahmad, Mohd. Ridzuan Capacitance-based microfluidic device for early ammonia detection in river water |
description |
This paper proposes a design of a microfluidic device for early detection of ammonia in river water based on capacitance measurement. A microfluidic device is designed and simulated to measure the content of ammonia in river water by using the COMSOL finite element analysis (FEA) software. This paper describes the system in detail from the conceptual idea to the hardware implementation. The microfluidic device works by inserting the sample of water into the device to be tested. A pair of electrodes is connected to the electrical circuit and the value of the capacitance of the water sample is measured. The tested samples are normal river water and contaminated river water which have ammonia in it. Several investigations have been done via the simulation, i.e. the size of the electrode, the difference in water flow gap, the distance between the electrode, speed of the water and the capacitance of the water. The results show that the proposed microfluidic design is capable to detect ammonia inside river water under 2 ppm concentration. |
format |
Article |
author |
Ramli, Muhammad Muhaimin Ahmad, Mohd. Ridzuan |
author_facet |
Ramli, Muhammad Muhaimin Ahmad, Mohd. Ridzuan |
author_sort |
Ramli, Muhammad Muhaimin |
title |
Capacitance-based microfluidic device for early ammonia detection in river water |
title_short |
Capacitance-based microfluidic device for early ammonia detection in river water |
title_full |
Capacitance-based microfluidic device for early ammonia detection in river water |
title_fullStr |
Capacitance-based microfluidic device for early ammonia detection in river water |
title_full_unstemmed |
Capacitance-based microfluidic device for early ammonia detection in river water |
title_sort |
capacitance-based microfluidic device for early ammonia detection in river water |
publisher |
Institute of Advanced Engineering and Science |
publishDate |
2020 |
url |
http://eprints.utm.my/id/eprint/91500/1/MohdRidzuanAhmad2020_Capacitance-BasedMicrofluidicDeviceforEarlyAmmoniaDetection.pdf http://eprints.utm.my/id/eprint/91500/ http://dx.doi.org/10.11591/ijeecs.v20.i2.pp761-767 |
_version_ |
1705056722606882816 |
score |
13.209306 |