Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor

Partial discharges (PD) occur in high voltage equipment are considered as major problem that required to be prevented to avoid any breakdown, damage and loss from happening. In addition, this pre-breakdown phenomenon can be detected using appropriate sensors such as acoustic emission sensor. In this...

Full description

Saved in:
Bibliographic Details
Main Authors: Kumar, C. G. L. P., Arizu, I., Nasib, A. H. M., Ahmad, M. H., Nawawi, Z., Sidik, M. A., Jambak, M. I., Kurnia, R. F., Mohd. Noor, M. Y., Azmi, I. A., Waldi, E. P., Aulia, Aulia
Format: Conference or Workshop Item
Language:English
Published: 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/90714/1/CLGPavanKumar2019_AcousticPartialDischargeDetection.pdf
http://eprints.utm.my/id/eprint/90714/
http://dx.doi.org/10.1109/ICECOS.2018.8605187
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.90714
record_format eprints
spelling my.utm.907142021-04-30T14:28:12Z http://eprints.utm.my/id/eprint/90714/ Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor Kumar, C. G. L. P. Arizu, I. Nasib, A. H. M. Ahmad, M. H. Nawawi, Z. Sidik, M. A. Jambak, M. I. Kurnia, R. F. Mohd. Noor, M. Y. Azmi, I. A. Waldi, E. P. Aulia, Aulia TK Electrical engineering. Electronics Nuclear engineering Partial discharges (PD) occur in high voltage equipment are considered as major problem that required to be prevented to avoid any breakdown, damage and loss from happening. In addition, this pre-breakdown phenomenon can be detected using appropriate sensors such as acoustic emission sensor. In this study, acoustic emission sensor was chosen as the method to detect the PD in high voltage insulation. Low-cost piezoelectric transducer (PZT) with pre-amplifier and optical fiber sensor (OFS) were used as a sensing device to detect PD but OFS was expected to highlight its usage towards PD detection. Development of optical fiber sensor (OFS) based on Single Mode-Multi Mode-Single Mode (SMS) structure which implementing a Multimode Interference effects (MMI) was focused on. PD measurement test was conducted according to IEC 60270 and IEC TS 62478 standards. A coated SMS based OFS was fabricated and then was used in PD measurement test. Furthermore, after implementing the pre-amplified PZT sensor and coated OFS in PD measurement test, results were compared with a measuring impedance by analyzing the Phase Resolved Partial Discharge (PRPD) patterns. From the results, all sensors can detect PD as accurately as the MI but the usage of pre-amplifier on PZT has shown a great deal of advantage in removing noises and amplifying small signal, but the SMS coated OFS has shown similar ability in detecting the PD. 2019 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/90714/1/CLGPavanKumar2019_AcousticPartialDischargeDetection.pdf Kumar, C. G. L. P. and Arizu, I. and Nasib, A. H. M. and Ahmad, M. H. and Nawawi, Z. and Sidik, M. A. and Jambak, M. I. and Kurnia, R. F. and Mohd. Noor, M. Y. and Azmi, I. A. and Waldi, E. P. and Aulia, Aulia (2019) Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor. In: 2018 International Conference on Electrical Engineering and Computer Science (ICECOS), 2-4 Oct 2018, Pangkal, Indonesia. http://dx.doi.org/10.1109/ICECOS.2018.8605187
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Kumar, C. G. L. P.
Arizu, I.
Nasib, A. H. M.
Ahmad, M. H.
Nawawi, Z.
Sidik, M. A.
Jambak, M. I.
Kurnia, R. F.
Mohd. Noor, M. Y.
Azmi, I. A.
Waldi, E. P.
Aulia, Aulia
Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor
description Partial discharges (PD) occur in high voltage equipment are considered as major problem that required to be prevented to avoid any breakdown, damage and loss from happening. In addition, this pre-breakdown phenomenon can be detected using appropriate sensors such as acoustic emission sensor. In this study, acoustic emission sensor was chosen as the method to detect the PD in high voltage insulation. Low-cost piezoelectric transducer (PZT) with pre-amplifier and optical fiber sensor (OFS) were used as a sensing device to detect PD but OFS was expected to highlight its usage towards PD detection. Development of optical fiber sensor (OFS) based on Single Mode-Multi Mode-Single Mode (SMS) structure which implementing a Multimode Interference effects (MMI) was focused on. PD measurement test was conducted according to IEC 60270 and IEC TS 62478 standards. A coated SMS based OFS was fabricated and then was used in PD measurement test. Furthermore, after implementing the pre-amplified PZT sensor and coated OFS in PD measurement test, results were compared with a measuring impedance by analyzing the Phase Resolved Partial Discharge (PRPD) patterns. From the results, all sensors can detect PD as accurately as the MI but the usage of pre-amplifier on PZT has shown a great deal of advantage in removing noises and amplifying small signal, but the SMS coated OFS has shown similar ability in detecting the PD.
format Conference or Workshop Item
author Kumar, C. G. L. P.
Arizu, I.
Nasib, A. H. M.
Ahmad, M. H.
Nawawi, Z.
Sidik, M. A.
Jambak, M. I.
Kurnia, R. F.
Mohd. Noor, M. Y.
Azmi, I. A.
Waldi, E. P.
Aulia, Aulia
author_facet Kumar, C. G. L. P.
Arizu, I.
Nasib, A. H. M.
Ahmad, M. H.
Nawawi, Z.
Sidik, M. A.
Jambak, M. I.
Kurnia, R. F.
Mohd. Noor, M. Y.
Azmi, I. A.
Waldi, E. P.
Aulia, Aulia
author_sort Kumar, C. G. L. P.
title Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor
title_short Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor
title_full Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor
title_fullStr Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor
title_full_unstemmed Acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor
title_sort acoustic partial discharge detection using lowcost pre-amplified piezoelectric transducer and coated optical fiber sensor
publishDate 2019
url http://eprints.utm.my/id/eprint/90714/1/CLGPavanKumar2019_AcousticPartialDischargeDetection.pdf
http://eprints.utm.my/id/eprint/90714/
http://dx.doi.org/10.1109/ICECOS.2018.8605187
_version_ 1698696974990049280
score 13.211869