Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection

Commonly, the cold-formed connection used screwed joint that advantages in simple and fast installation. However, the screw connections should have many problems when it applied for primary structure such as beam and column. To solve this problem, it can be applied the bolted connections using slip...

Full description

Saved in:
Bibliographic Details
Main Authors: Aminuddin, K. M., Saggaff, A., Tahir, M. M.
Format: Article
Published: International Journal of Scientific and Technology Research 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/90259/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.90259
record_format eprints
spelling my.utm.902592021-03-30T07:48:50Z http://eprints.utm.my/id/eprint/90259/ Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection Aminuddin, K. M. Saggaff, A. Tahir, M. M. TA Engineering (General). Civil engineering (General) Commonly, the cold-formed connection used screwed joint that advantages in simple and fast installation. However, the screw connections should have many problems when it applied for primary structure such as beam and column. To solve this problem, it can be applied the bolted connections using slip in gusset plate as primary structure. The aims of this paper to study the behaviour slip-in gusset plate connection for double lipped channel C20024 using sub-assemblage frame test. The proposed of connections were rectangular gusset plate (RG) and haunched gusset plate (HG). The failure mode, moment resistance, classification connection and discussion will be presented in this paper. The failure mode of bearing bolt CFS was occur for isolated joint test specimens. All of specimens sub-assemblage frame test have similar failure modes where the beam had lateral torsional buckling. The moment resistance of sub-assemblage frame test for RG connection was 13.17 kNm and HG connection was 17.76 kNm. The classification of strength for all sub-assemblage frame test specimens test were classified as partial strength connection. International Journal of Scientific and Technology Research 2019-09 Article PeerReviewed Aminuddin, K. M. and Saggaff, A. and Tahir, M. M. (2019) Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection. International Journal of Scientific and Technology Research, 8 (9). pp. 89-95. ISSN 2277-8616
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Aminuddin, K. M.
Saggaff, A.
Tahir, M. M.
Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection
description Commonly, the cold-formed connection used screwed joint that advantages in simple and fast installation. However, the screw connections should have many problems when it applied for primary structure such as beam and column. To solve this problem, it can be applied the bolted connections using slip in gusset plate as primary structure. The aims of this paper to study the behaviour slip-in gusset plate connection for double lipped channel C20024 using sub-assemblage frame test. The proposed of connections were rectangular gusset plate (RG) and haunched gusset plate (HG). The failure mode, moment resistance, classification connection and discussion will be presented in this paper. The failure mode of bearing bolt CFS was occur for isolated joint test specimens. All of specimens sub-assemblage frame test have similar failure modes where the beam had lateral torsional buckling. The moment resistance of sub-assemblage frame test for RG connection was 13.17 kNm and HG connection was 17.76 kNm. The classification of strength for all sub-assemblage frame test specimens test were classified as partial strength connection.
format Article
author Aminuddin, K. M.
Saggaff, A.
Tahir, M. M.
author_facet Aminuddin, K. M.
Saggaff, A.
Tahir, M. M.
author_sort Aminuddin, K. M.
title Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection
title_short Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection
title_full Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection
title_fullStr Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection
title_full_unstemmed Structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection
title_sort structural behaviour of slip-in gusset plate connection for double lipped channel cold formed steel using partial strength connection
publisher International Journal of Scientific and Technology Research
publishDate 2019
url http://eprints.utm.my/id/eprint/90259/
_version_ 1696976284515565568
score 13.209306