Seismic control of a building structure equip with hybrid mass damper using sliding mode control

This paper addresses the issue of the impact of controllers in suppressing the vibration of structural building during seismic. It is important to implement an appropriate controller to avoid a huge impact to the building structure from damage and collapse while earthquake occur. Sliding mode contro...

Full description

Saved in:
Bibliographic Details
Main Authors: Mamat, Normaisharah, Yakub, Fitri, Shaikh Salim, Sheikh Ahmad Zaki, Ab. Rashid, Mohd. Zamzuri, Munawarah, Sharifah, Roslan, Shairatul Akma
Format: Conference or Workshop Item
Published: 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/89795/
http://dx.doi.org/10.1007/978-981-13-9539-0_15
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.89795
record_format eprints
spelling my.utm.897952021-03-04T02:45:51Z http://eprints.utm.my/id/eprint/89795/ Seismic control of a building structure equip with hybrid mass damper using sliding mode control Mamat, Normaisharah Yakub, Fitri Shaikh Salim, Sheikh Ahmad Zaki Ab. Rashid, Mohd. Zamzuri Munawarah, Sharifah Roslan, Shairatul Akma TA Engineering (General). Civil engineering (General) This paper addresses the issue of the impact of controllers in suppressing the vibration of structural building during seismic. It is important to implement an appropriate controller to avoid a huge impact to the building structure from damage and collapse while earthquake occur. Sliding mode controller (SMC) and proportional-integral-derivative (PID) are proposed to alleviate the vibration. SMC is selected as control strategy because of its robust control technique that can reject the disturbances while PID is known as simple control design. The simulation for two storey building equipped with structural control device which known as hybrid mass damper placed at the top floor of the structure that represent by mass, spring and damper are constructed by using Matlab/Simulink. The input excitation to the structure is taken from El Centro earthquake with magnitude of 6.9 Mw. The output response for the system generates displacement, velocity, control input, and frequency response. Based from the result, SMC has better performance compared to PID and overall SMC is success to suppress the building vibration according to the displacement performance obtained. 2020-07 Conference or Workshop Item PeerReviewed Mamat, Normaisharah and Yakub, Fitri and Shaikh Salim, Sheikh Ahmad Zaki and Ab. Rashid, Mohd. Zamzuri and Munawarah, Sharifah and Roslan, Shairatul Akma (2020) Seismic control of a building structure equip with hybrid mass damper using sliding mode control. In: 2nd Symposium on Intelligent Manufacturing and Mechatronics, SympoSIMM 2019, 8 July 2019 through 8 July 2019, Melaka, Malaysia. http://dx.doi.org/10.1007/978-981-13-9539-0_15
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Mamat, Normaisharah
Yakub, Fitri
Shaikh Salim, Sheikh Ahmad Zaki
Ab. Rashid, Mohd. Zamzuri
Munawarah, Sharifah
Roslan, Shairatul Akma
Seismic control of a building structure equip with hybrid mass damper using sliding mode control
description This paper addresses the issue of the impact of controllers in suppressing the vibration of structural building during seismic. It is important to implement an appropriate controller to avoid a huge impact to the building structure from damage and collapse while earthquake occur. Sliding mode controller (SMC) and proportional-integral-derivative (PID) are proposed to alleviate the vibration. SMC is selected as control strategy because of its robust control technique that can reject the disturbances while PID is known as simple control design. The simulation for two storey building equipped with structural control device which known as hybrid mass damper placed at the top floor of the structure that represent by mass, spring and damper are constructed by using Matlab/Simulink. The input excitation to the structure is taken from El Centro earthquake with magnitude of 6.9 Mw. The output response for the system generates displacement, velocity, control input, and frequency response. Based from the result, SMC has better performance compared to PID and overall SMC is success to suppress the building vibration according to the displacement performance obtained.
format Conference or Workshop Item
author Mamat, Normaisharah
Yakub, Fitri
Shaikh Salim, Sheikh Ahmad Zaki
Ab. Rashid, Mohd. Zamzuri
Munawarah, Sharifah
Roslan, Shairatul Akma
author_facet Mamat, Normaisharah
Yakub, Fitri
Shaikh Salim, Sheikh Ahmad Zaki
Ab. Rashid, Mohd. Zamzuri
Munawarah, Sharifah
Roslan, Shairatul Akma
author_sort Mamat, Normaisharah
title Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_short Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_full Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_fullStr Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_full_unstemmed Seismic control of a building structure equip with hybrid mass damper using sliding mode control
title_sort seismic control of a building structure equip with hybrid mass damper using sliding mode control
publishDate 2020
url http://eprints.utm.my/id/eprint/89795/
http://dx.doi.org/10.1007/978-981-13-9539-0_15
_version_ 1693725946939441152
score 13.159267