Hemodynamic characteristics in aorta-pulmonary artery system

The child patients of hypoplastic left heart syndrome undergoes major operations such as the Norwood procedure, the Bidirectional Glenn procedure and the Fontan procedure. Patent Ductus Arteriosus (PDA) stenting, which is instead of these procedures, is recently performed to prevent closure of ductu...

Full description

Saved in:
Bibliographic Details
Main Authors: Ichihashi, D., Iinuma, M., Yamamoto, T., Kori, Mohamad Ikhwan, Osman, K. B.
Format: Conference or Workshop Item
Language:English
Published: 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/89557/1/MohamadIkhwanKori2019_HemodynamicCharacteristicsinAortaPulmonaryArtery.pdf
http://eprints.utm.my/id/eprint/89557/
http://dx.doi.org/10.1088/1757-899X/501/1/012037
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.89557
record_format eprints
spelling my.utm.895572021-02-22T06:08:16Z http://eprints.utm.my/id/eprint/89557/ Hemodynamic characteristics in aorta-pulmonary artery system Ichihashi, D. Iinuma, M. Yamamoto, T. Kori, Mohamad Ikhwan Osman, K. B. QH301 Biology QM Human anatomy The child patients of hypoplastic left heart syndrome undergoes major operations such as the Norwood procedure, the Bidirectional Glenn procedure and the Fontan procedure. Patent Ductus Arteriosus (PDA) stenting, which is instead of these procedures, is recently performed to prevent closure of ductus arteriosus and to alleviate the burden for the patient. This study clarified that hemodynamics in aorta-pulmonary artery system and mechanism of thrombus formation using Computational Fluid Dynamics (CFD) analysis and Particle Imaging Velocimetry (PIV) measurement. As a result of CFD analysis, low wall shear stress was observed at neighborhood of PDA stent. From results of CFD analysis and PIV measurement, the main blood flow was formed toward from aorta to pulmonary artery and there is no blood stagnation region in PDA. 2019-04-09 Conference or Workshop Item PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/89557/1/MohamadIkhwanKori2019_HemodynamicCharacteristicsinAortaPulmonaryArtery.pdf Ichihashi, D. and Iinuma, M. and Yamamoto, T. and Kori, Mohamad Ikhwan and Osman, K. B. (2019) Hemodynamic characteristics in aorta-pulmonary artery system. In: 9th Thai Society of Mechanical Engineers, International Conference on Mechanical Engineering, TSME-ICoME 2018, 11 December 2018 through 14 December 2018, Tavorn Palm Beach Resort Phuket, Thailand. http://dx.doi.org/10.1088/1757-899X/501/1/012037
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic QH301 Biology
QM Human anatomy
spellingShingle QH301 Biology
QM Human anatomy
Ichihashi, D.
Iinuma, M.
Yamamoto, T.
Kori, Mohamad Ikhwan
Osman, K. B.
Hemodynamic characteristics in aorta-pulmonary artery system
description The child patients of hypoplastic left heart syndrome undergoes major operations such as the Norwood procedure, the Bidirectional Glenn procedure and the Fontan procedure. Patent Ductus Arteriosus (PDA) stenting, which is instead of these procedures, is recently performed to prevent closure of ductus arteriosus and to alleviate the burden for the patient. This study clarified that hemodynamics in aorta-pulmonary artery system and mechanism of thrombus formation using Computational Fluid Dynamics (CFD) analysis and Particle Imaging Velocimetry (PIV) measurement. As a result of CFD analysis, low wall shear stress was observed at neighborhood of PDA stent. From results of CFD analysis and PIV measurement, the main blood flow was formed toward from aorta to pulmonary artery and there is no blood stagnation region in PDA.
format Conference or Workshop Item
author Ichihashi, D.
Iinuma, M.
Yamamoto, T.
Kori, Mohamad Ikhwan
Osman, K. B.
author_facet Ichihashi, D.
Iinuma, M.
Yamamoto, T.
Kori, Mohamad Ikhwan
Osman, K. B.
author_sort Ichihashi, D.
title Hemodynamic characteristics in aorta-pulmonary artery system
title_short Hemodynamic characteristics in aorta-pulmonary artery system
title_full Hemodynamic characteristics in aorta-pulmonary artery system
title_fullStr Hemodynamic characteristics in aorta-pulmonary artery system
title_full_unstemmed Hemodynamic characteristics in aorta-pulmonary artery system
title_sort hemodynamic characteristics in aorta-pulmonary artery system
publishDate 2019
url http://eprints.utm.my/id/eprint/89557/1/MohamadIkhwanKori2019_HemodynamicCharacteristicsinAortaPulmonaryArtery.pdf
http://eprints.utm.my/id/eprint/89557/
http://dx.doi.org/10.1088/1757-899X/501/1/012037
_version_ 1692991797128593408
score 13.209306