Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner

A pilot-scale investigation with Selective Non-catalytic Reduction (SNCR) of NOx were carried out by employing the aqueous solution of commercial grade ammonia liquor as NOx reducing agent in diesel burning exhaust at 6% excess oxygen and injection temperatures between 923 and 1323 K. The furnace si...

Full description

Saved in:
Bibliographic Details
Main Authors: Hossain, Khandoker Abul, Mohd. Jaafar, Mohammad Nazrim, Mustafa, Azeman, Ani, Farid Nasir
Format: Article
Language:English
Published: Penerbit UTM Press 2005
Subjects:
Online Access:http://eprints.utm.my/id/eprint/894/1/MohdammadNasriMohd2005%29ApplicationofCommercialGradeAmmonia.pdf
http://eprints.utm.my/id/eprint/894/
http://www.penerbit.utm.my/onlinejournal/42/A/JTJUN42A8.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.894
record_format eprints
spelling my.utm.8942017-11-01T04:17:34Z http://eprints.utm.my/id/eprint/894/ Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner Hossain, Khandoker Abul Mohd. Jaafar, Mohammad Nazrim Mustafa, Azeman Ani, Farid Nasir TP Chemical technology A pilot-scale investigation with Selective Non-catalytic Reduction (SNCR) of NOx were carried out by employing the aqueous solution of commercial grade ammonia liquor as NOx reducing agent in diesel burning exhaust at 6% excess oxygen and injection temperatures between 923 and 1323 K. The furnace simulated the small-scale combustion systems such as low capacity boilers, water heaters, oil heaters etc., which produce low level of baseline NOx usually below 100 ppm and where the operating temperatures remain within the investigated temperature range. With 5% aqueous ammonia solution, at a Normalised Stoichiomehic Ratio (NSR) of 4, as much as 57% reduction was achieved at an optimum temperature of 1063 K, which is quite significant for the investigated level of baseline NOx. The NOx reduction was observed to increase as the value of NSR increased. The residence time of the reagent has significant effect on the reaction performance, however, most of the reduction occurred within a short range of residence time and after that further increase in residence time showed very insignificant effect. The ammonia slip measurement showed that at optimum temperature and NSR of 4, the slip was about 18 ppm. The investigations demonstrate that commercial grade liquor ammonia is a potential NOx reducing agent, which could be used effectively and safely considering the health hazards. Penerbit UTM Press 2005-06 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/894/1/MohdammadNasriMohd2005%29ApplicationofCommercialGradeAmmonia.pdf Hossain, Khandoker Abul and Mohd. Jaafar, Mohammad Nazrim and Mustafa, Azeman and Ani, Farid Nasir (2005) Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner. Jurnal Teknologi (42A). pp. 107-118. ISSN 0127-9696 http://www.penerbit.utm.my/onlinejournal/42/A/JTJUN42A8.pdf
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Hossain, Khandoker Abul
Mohd. Jaafar, Mohammad Nazrim
Mustafa, Azeman
Ani, Farid Nasir
Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner
description A pilot-scale investigation with Selective Non-catalytic Reduction (SNCR) of NOx were carried out by employing the aqueous solution of commercial grade ammonia liquor as NOx reducing agent in diesel burning exhaust at 6% excess oxygen and injection temperatures between 923 and 1323 K. The furnace simulated the small-scale combustion systems such as low capacity boilers, water heaters, oil heaters etc., which produce low level of baseline NOx usually below 100 ppm and where the operating temperatures remain within the investigated temperature range. With 5% aqueous ammonia solution, at a Normalised Stoichiomehic Ratio (NSR) of 4, as much as 57% reduction was achieved at an optimum temperature of 1063 K, which is quite significant for the investigated level of baseline NOx. The NOx reduction was observed to increase as the value of NSR increased. The residence time of the reagent has significant effect on the reaction performance, however, most of the reduction occurred within a short range of residence time and after that further increase in residence time showed very insignificant effect. The ammonia slip measurement showed that at optimum temperature and NSR of 4, the slip was about 18 ppm. The investigations demonstrate that commercial grade liquor ammonia is a potential NOx reducing agent, which could be used effectively and safely considering the health hazards.
format Article
author Hossain, Khandoker Abul
Mohd. Jaafar, Mohammad Nazrim
Mustafa, Azeman
Ani, Farid Nasir
author_facet Hossain, Khandoker Abul
Mohd. Jaafar, Mohammad Nazrim
Mustafa, Azeman
Ani, Farid Nasir
author_sort Hossain, Khandoker Abul
title Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner
title_short Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner
title_full Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner
title_fullStr Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner
title_full_unstemmed Application Of Commercial Grade Ammonia Liquor In The Selective Non-Catalytic Reduction Of Nox In Combusted Gas From A Diesel Burner
title_sort application of commercial grade ammonia liquor in the selective non-catalytic reduction of nox in combusted gas from a diesel burner
publisher Penerbit UTM Press
publishDate 2005
url http://eprints.utm.my/id/eprint/894/1/MohdammadNasriMohd2005%29ApplicationofCommercialGradeAmmonia.pdf
http://eprints.utm.my/id/eprint/894/
http://www.penerbit.utm.my/onlinejournal/42/A/JTJUN42A8.pdf
_version_ 1643643209431121920
score 13.209306