Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal
An analytical method for the determination of histamine using metals and alizarin red S (ARS) reagents by UV-Visible spectrophotometry was developed. Cu(II), Co(II) and ARS were used to form colored complex with histamine. The developed method was used to detect qualitatively and quantitatively the...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Malaysian Society of Analytical Sciences
2019
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/88747/1/GandenSupriyanto2019_RapidSpectrophotometricMethodforHistamine.pdf http://eprints.utm.my/id/eprint/88747/ https://dx.doi.org/10.17576/mjas-2019-2303-15 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.88747 |
---|---|
record_format |
eprints |
spelling |
my.utm.887472020-12-29T04:17:27Z http://eprints.utm.my/id/eprint/88747/ Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal Jannatin, M. Latjuba, A. N. I. Wahyuni, S. Supriyanto, G. Ibrahim, W. A. W. QD Chemistry An analytical method for the determination of histamine using metals and alizarin red S (ARS) reagents by UV-Visible spectrophotometry was developed. Cu(II), Co(II) and ARS were used to form colored complex with histamine. The developed method was used to detect qualitatively and quantitatively the presence of histamine. Absorbance of Cu(II) and Co(II) complex were measured at a maximum wavelength of 505.5 and 567 nm, respectively. Optimization of analytical parameters such as concentration of metals, concentration of ARS, sample solution pH, and optimum time for complex formation were performed. Experimental results showed that the optimum concentration of Cu(II) was 50 ppm, 75 ppm ARS, sample solution pH 6, and 15 minutes optimum time, while the optimum concentration of Co(II) was 125 ppm, ARS was 75 and 50 ppm, sample solution pH 5 and 10 minutes optimum time. Method validation indicated that the coefficient of variation, limit of detection (LOD) (S/N =3), and limit of quantitation (LOQ = 10S/N) of Cu(II) were 0.65%, 8.94 ppm, and 29.82 ppm respectively with a sensitivity of 0.0054 ppm and linearity of 0.9959. Accuracy of histamine determination through Cu-ARS-histamine complex at a concentration of 50, 100, and 150 ppm were 105.7% (RSD = 0.777%, n = 3), 105.06% (RSD = 0.606%, n = 3), and 94.12% (RSD = 0.767%, n = 3), respectively. Meanwhile, the CV, LOD, and LOQ of Co(II) were 0.28%; 2.58 ppm; and 8.6 ppm respectively with a sensitivity of 0.0006 ppm and linearity of 0.9965. Accuracy of histamine determination through Co-ARS-histamine complex at a concentration of 50, 75, and 125 ppm were 98.33%, 95.83%, 93.88%, respectively. The proposed method was successfully applied to the determination of histamine in a fish sample with quantitative recovery; for Cu(II) complex (99.23%) and Co(II) complex (102.62%). Malaysian Society of Analytical Sciences 2019 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/88747/1/GandenSupriyanto2019_RapidSpectrophotometricMethodforHistamine.pdf Jannatin, M. and Latjuba, A. N. I. and Wahyuni, S. and Supriyanto, G. and Ibrahim, W. A. W. (2019) Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal. Malaysian Journal of Analytical Sciences, 23 (3). ISSN 1394-2506 https://dx.doi.org/10.17576/mjas-2019-2303-15 DOI:10.17576/mjas-2019-2303-15 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
QD Chemistry |
spellingShingle |
QD Chemistry Jannatin, M. Latjuba, A. N. I. Wahyuni, S. Supriyanto, G. Ibrahim, W. A. W. Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal |
description |
An analytical method for the determination of histamine using metals and alizarin red S (ARS) reagents by UV-Visible spectrophotometry was developed. Cu(II), Co(II) and ARS were used to form colored complex with histamine. The developed method was used to detect qualitatively and quantitatively the presence of histamine. Absorbance of Cu(II) and Co(II) complex were measured at a maximum wavelength of 505.5 and 567 nm, respectively. Optimization of analytical parameters such as concentration of metals, concentration of ARS, sample solution pH, and optimum time for complex formation were performed. Experimental results showed that the optimum concentration of Cu(II) was 50 ppm, 75 ppm ARS, sample solution pH 6, and 15 minutes optimum time, while the optimum concentration of Co(II) was 125 ppm, ARS was 75 and 50 ppm, sample solution pH 5 and 10 minutes optimum time. Method validation indicated that the coefficient of variation, limit of detection (LOD) (S/N =3), and limit of quantitation (LOQ = 10S/N) of Cu(II) were 0.65%, 8.94 ppm, and 29.82 ppm respectively with a sensitivity of 0.0054 ppm and linearity of 0.9959. Accuracy of histamine determination through Cu-ARS-histamine complex at a concentration of 50, 100, and 150 ppm were 105.7% (RSD = 0.777%, n = 3), 105.06% (RSD = 0.606%, n = 3), and 94.12% (RSD = 0.767%, n = 3), respectively. Meanwhile, the CV, LOD, and LOQ of Co(II) were 0.28%; 2.58 ppm; and 8.6 ppm respectively with a sensitivity of 0.0006 ppm and linearity of 0.9965. Accuracy of histamine determination through Co-ARS-histamine complex at a concentration of 50, 75, and 125 ppm were 98.33%, 95.83%, 93.88%, respectively. The proposed method was successfully applied to the determination of histamine in a fish sample with quantitative recovery; for Cu(II) complex (99.23%) and Co(II) complex (102.62%). |
format |
Article |
author |
Jannatin, M. Latjuba, A. N. I. Wahyuni, S. Supriyanto, G. Ibrahim, W. A. W. |
author_facet |
Jannatin, M. Latjuba, A. N. I. Wahyuni, S. Supriyanto, G. Ibrahim, W. A. W. |
author_sort |
Jannatin, M. |
title |
Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal |
title_short |
Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal |
title_full |
Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal |
title_fullStr |
Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal |
title_full_unstemmed |
Rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal |
title_sort |
rapid spectrophotometric method for histamine determination in fish using alizarin red s and metal |
publisher |
Malaysian Society of Analytical Sciences |
publishDate |
2019 |
url |
http://eprints.utm.my/id/eprint/88747/1/GandenSupriyanto2019_RapidSpectrophotometricMethodforHistamine.pdf http://eprints.utm.my/id/eprint/88747/ https://dx.doi.org/10.17576/mjas-2019-2303-15 |
_version_ |
1687393615783919616 |
score |
13.209306 |