Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia

The student spends the majority of their time in the classroom to participate in the learning and teaching session. Recently, there are plenty of issues reported from the building occupants due to poor thermal comfort in the building. A poor indoor thermal could lead to Sick Building Syndrome (SBS),...

Full description

Saved in:
Bibliographic Details
Main Authors: Zuhari, Zuhairah, Low, Sheau-Ting
Format: Article
Language:English
Published: Centre for Real Estate Studies Pub. 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/88430/1/LowSheau-Ting2019_IndoorThermalComfortinUniversityClassroom.pdf
http://eprints.utm.my/id/eprint/88430/
https://www.utm.my/intrest/files/2020/01/INDOOR-THERMAL-COMFORT-IN-UNIVERSITY-CLASSROOM-A-CASE-OF-UNIVERSITI-TEKNOLOGI-MALAYSIA.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.88430
record_format eprints
spelling my.utm.884302020-12-15T10:53:20Z http://eprints.utm.my/id/eprint/88430/ Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia Zuhari, Zuhairah Low, Sheau-Ting T Technology (General) The student spends the majority of their time in the classroom to participate in the learning and teaching session. Recently, there are plenty of issues reported from the building occupants due to poor thermal comfort in the building. A poor indoor thermal could lead to Sick Building Syndrome (SBS), unproductive and unhappy occupants. A conducive indoor thermal environment, on the other hand, helps the occupants to perform well, such as increasing their ability to focus, become more productive and not easily get an illness. This study aims to investigate the indoor thermal comfort level of classrooms in a university. Empirical data were collected from field observation which was held in two sessions (morning and evening) in February 2019 in 40 classrooms. The results showed that 70 % of the classrooms have complied with the existing standard of air temperature and 85 % of the classrooms have complied with the standard of relative humidity. All of the classrooms were recorded with a higher level of air velocity as required in the standard. The findings of this study can provide a guide for facilities manager to improve the indoor thermal comfort level in the classroom and increase awareness among building users on the importance of conducive indoor thermal comfort. Centre for Real Estate Studies Pub. 2019 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/88430/1/LowSheau-Ting2019_IndoorThermalComfortinUniversityClassroom.pdf Zuhari, Zuhairah and Low, Sheau-Ting (2019) Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia. International Journal of Real Estate Studies, 13 (2). pp. 34-41. ISSN 1823-8505 https://www.utm.my/intrest/files/2020/01/INDOOR-THERMAL-COMFORT-IN-UNIVERSITY-CLASSROOM-A-CASE-OF-UNIVERSITI-TEKNOLOGI-MALAYSIA.pdf
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Zuhari, Zuhairah
Low, Sheau-Ting
Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia
description The student spends the majority of their time in the classroom to participate in the learning and teaching session. Recently, there are plenty of issues reported from the building occupants due to poor thermal comfort in the building. A poor indoor thermal could lead to Sick Building Syndrome (SBS), unproductive and unhappy occupants. A conducive indoor thermal environment, on the other hand, helps the occupants to perform well, such as increasing their ability to focus, become more productive and not easily get an illness. This study aims to investigate the indoor thermal comfort level of classrooms in a university. Empirical data were collected from field observation which was held in two sessions (morning and evening) in February 2019 in 40 classrooms. The results showed that 70 % of the classrooms have complied with the existing standard of air temperature and 85 % of the classrooms have complied with the standard of relative humidity. All of the classrooms were recorded with a higher level of air velocity as required in the standard. The findings of this study can provide a guide for facilities manager to improve the indoor thermal comfort level in the classroom and increase awareness among building users on the importance of conducive indoor thermal comfort.
format Article
author Zuhari, Zuhairah
Low, Sheau-Ting
author_facet Zuhari, Zuhairah
Low, Sheau-Ting
author_sort Zuhari, Zuhairah
title Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia
title_short Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia
title_full Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia
title_fullStr Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia
title_full_unstemmed Indoor thermal comfort in university classroom: a case of Universiti Teknologi Malaysia
title_sort indoor thermal comfort in university classroom: a case of universiti teknologi malaysia
publisher Centre for Real Estate Studies Pub.
publishDate 2019
url http://eprints.utm.my/id/eprint/88430/1/LowSheau-Ting2019_IndoorThermalComfortinUniversityClassroom.pdf
http://eprints.utm.my/id/eprint/88430/
https://www.utm.my/intrest/files/2020/01/INDOOR-THERMAL-COMFORT-IN-UNIVERSITY-CLASSROOM-A-CASE-OF-UNIVERSITI-TEKNOLOGI-MALAYSIA.pdf
_version_ 1687393570253701120
score 13.18916