Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples

A new automated flow-through adsorption/desorption procedure using a multiwalled carbon nanotube immobilised mixed matrix membrane is described. The membrane consisted of 25% (w/w) multiwall carbon nanotube loading in a cellulose triacetate polymer matrix as support and was cast and embedded in a fl...

Full description

Saved in:
Bibliographic Details
Main Authors: Ganesan, T., Lim, H. N., See, H. H.
Format: Article
Published: Springer 2020
Subjects:
Online Access:http://eprints.utm.my/id/eprint/88060/
http://www.dx.doi.org/ 10.1007/s10337-020-03865-4
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.88060
record_format eprints
spelling my.utm.880602020-11-30T13:50:56Z http://eprints.utm.my/id/eprint/88060/ Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples Ganesan, T. Lim, H. N. See, H. H. QD Chemistry A new automated flow-through adsorption/desorption procedure using a multiwalled carbon nanotube immobilised mixed matrix membrane is described. The membrane consisted of 25% (w/w) multiwall carbon nanotube loading in a cellulose triacetate polymer matrix as support and was cast and embedded in a flow-through cell with a channel of an approximate length of 20 mm, a width of 2 mm, and a depth of 1.5 mm. The membrane immobilised with nanoparticles was activated using 1-octanol as a conditioning solvent. For the analyte adsorption process, 6 mL of the sample was passed through the cell at a flow rate of 0.2 mL min(-1). The entrapped target analytes were then desorbed dynamically with 60 mu L of 2-propanal at a flow rate of 5 mu L min(-1) prior to HPLC/UV analysis. The performance of the system was demonstrated for the determination of chlorinated phenoxyacetic acid herbicides in sewage water samples. Under the optimum conditions, the linearity of this method ranged from 50 to 1000 ng mL(-1), with a correlation coefficient (r) >= 0.993 and a detection limit varying from 15 to 20 ng mL(-1). Enrichment factors of up to 55 were achieved with relative recoveries of 95-99% and precision values of 6.1-7.5%. Springer 2020 Article PeerReviewed Ganesan, T. and Lim, H. N. and See, H. H. (2020) Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples. Chromatographia, 83 (4). pp. 497-505. http://www.dx.doi.org/ 10.1007/s10337-020-03865-4 DOI: 10.1007/s10337-020-03865-4
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QD Chemistry
spellingShingle QD Chemistry
Ganesan, T.
Lim, H. N.
See, H. H.
Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples
description A new automated flow-through adsorption/desorption procedure using a multiwalled carbon nanotube immobilised mixed matrix membrane is described. The membrane consisted of 25% (w/w) multiwall carbon nanotube loading in a cellulose triacetate polymer matrix as support and was cast and embedded in a flow-through cell with a channel of an approximate length of 20 mm, a width of 2 mm, and a depth of 1.5 mm. The membrane immobilised with nanoparticles was activated using 1-octanol as a conditioning solvent. For the analyte adsorption process, 6 mL of the sample was passed through the cell at a flow rate of 0.2 mL min(-1). The entrapped target analytes were then desorbed dynamically with 60 mu L of 2-propanal at a flow rate of 5 mu L min(-1) prior to HPLC/UV analysis. The performance of the system was demonstrated for the determination of chlorinated phenoxyacetic acid herbicides in sewage water samples. Under the optimum conditions, the linearity of this method ranged from 50 to 1000 ng mL(-1), with a correlation coefficient (r) >= 0.993 and a detection limit varying from 15 to 20 ng mL(-1). Enrichment factors of up to 55 were achieved with relative recoveries of 95-99% and precision values of 6.1-7.5%.
format Article
author Ganesan, T.
Lim, H. N.
See, H. H.
author_facet Ganesan, T.
Lim, H. N.
See, H. H.
author_sort Ganesan, T.
title Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples
title_short Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples
title_full Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples
title_fullStr Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples
title_full_unstemmed Automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples
title_sort automated mixed matrix membrane microextraction prior to liquid chromatography for the determination of chlorophenoxy acid herbicides in sewage water samples
publisher Springer
publishDate 2020
url http://eprints.utm.my/id/eprint/88060/
http://www.dx.doi.org/ 10.1007/s10337-020-03865-4
_version_ 1685579022470217728
score 13.18916