The scope of this study was to investigate the effect of the heat treatment process on the performance of the PEI hollow fiber membrane contactor for CO2 stripping process. The membranes were fabricated via a wet spinning technique into water as a non-solvent bath. Then, the membranes were heat trea...

Full description

Saved in:
Bibliographic Details
Main Authors: Hashemifard, S. A., Ahmadi, H., Ismail, A. F., Moarefian, Ahmad, Abdullah, M. S.
Format: Article
Published: Elsevier B. V. 2019
Subjects:
Online Access:http://eprints.utm.my/id/eprint/87434/
http://dx.doi.org/10.1016/j.seppur.2019.03.045
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.87434
record_format eprints
spelling my.utm.874342020-11-08T03:59:35Z http://eprints.utm.my/id/eprint/87434/ The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping Hashemifard, S. A. Ahmadi, H. Ismail, A. F. Moarefian, Ahmad Abdullah, M. S. TP Chemical technology The scope of this study was to investigate the effect of the heat treatment process on the performance of the PEI hollow fiber membrane contactor for CO2 stripping process. The membranes were fabricated via a wet spinning technique into water as a non-solvent bath. Then, the membranes were heat treated by exposing them to various temperatures of 80,120 and 160 °C for the time intervals of 5, 15 and 30 min under a hot air atmosphere. The observations revealed that the most pronounced enhancement belonged to the membranes with the lowest heat treatment temperature preferentially at the shorter exposure times. It was shown that the absorbent velocity and temperature had substantial influence on the CO2 stripping flux, however the temperature exhibited a stronger influence. In fact the dual functionality of temperature on the system i.e. (i)thermodynamics (by decrease in CO2 solubility)and (ii)kinetics (by increase in CO2 diffusivity)led to the enhancement in CO2 stripping flux. Also, it was revealed that by increasing the heat treatment temperature, more tendency toward the pore wetting will be observed. There was a meaningful correlation between the wetting ratio and the CO2 stripping flux. Also experimentally it was revealed that, a marginal progress in the wetting ratio, surprisingly caused to a dramatic decline in the stripping flux. Elsevier B. V. 2019-09 Article PeerReviewed Hashemifard, S. A. and Ahmadi, H. and Ismail, A. F. and Moarefian, Ahmad and Abdullah, M. S. (2019) The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping. Separation and Purification Technology, 223 . pp. 186-195. ISSN 1383-5866 http://dx.doi.org/10.1016/j.seppur.2019.03.045
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Hashemifard, S. A.
Ahmadi, H.
Ismail, A. F.
Moarefian, Ahmad
Abdullah, M. S.
The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping
description The scope of this study was to investigate the effect of the heat treatment process on the performance of the PEI hollow fiber membrane contactor for CO2 stripping process. The membranes were fabricated via a wet spinning technique into water as a non-solvent bath. Then, the membranes were heat treated by exposing them to various temperatures of 80,120 and 160 °C for the time intervals of 5, 15 and 30 min under a hot air atmosphere. The observations revealed that the most pronounced enhancement belonged to the membranes with the lowest heat treatment temperature preferentially at the shorter exposure times. It was shown that the absorbent velocity and temperature had substantial influence on the CO2 stripping flux, however the temperature exhibited a stronger influence. In fact the dual functionality of temperature on the system i.e. (i)thermodynamics (by decrease in CO2 solubility)and (ii)kinetics (by increase in CO2 diffusivity)led to the enhancement in CO2 stripping flux. Also, it was revealed that by increasing the heat treatment temperature, more tendency toward the pore wetting will be observed. There was a meaningful correlation between the wetting ratio and the CO2 stripping flux. Also experimentally it was revealed that, a marginal progress in the wetting ratio, surprisingly caused to a dramatic decline in the stripping flux.
format Article
author Hashemifard, S. A.
Ahmadi, H.
Ismail, A. F.
Moarefian, Ahmad
Abdullah, M. S.
author_facet Hashemifard, S. A.
Ahmadi, H.
Ismail, A. F.
Moarefian, Ahmad
Abdullah, M. S.
author_sort Hashemifard, S. A.
title The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping
title_short The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping
title_full The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping
title_fullStr The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping
title_full_unstemmed The effect of heat treatment on hollow fiber membrane contactor for CO2 stripping
title_sort effect of heat treatment on hollow fiber membrane contactor for co2 stripping
publisher Elsevier B. V.
publishDate 2019
url http://eprints.utm.my/id/eprint/87434/
http://dx.doi.org/10.1016/j.seppur.2019.03.045
_version_ 1683230767283437568
score 13.211869