Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre

In precast concrete slab, the coupling bars and in-situ concrete act as the precast slab panel connection. The design of coupling bars based on Eurocode 2 must be able to resist the horizontal shear force and the U-loop bar must also be design to carry this force. The placing of coupling bars as the...

Full description

Saved in:
Bibliographic Details
Main Author: Awaludin, Safiah Zaleha
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/86951/1/SafiahZalehaAwaludinMFKA2018.pdf
http://eprints.utm.my/id/eprint/86951/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:132583
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.86951
record_format eprints
spelling my.utm.869512020-10-30T05:13:38Z http://eprints.utm.my/id/eprint/86951/ Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre Awaludin, Safiah Zaleha TA Engineering (General). Civil engineering (General) In precast concrete slab, the coupling bars and in-situ concrete act as the precast slab panel connection. The design of coupling bars based on Eurocode 2 must be able to resist the horizontal shear force and the U-loop bar must also be design to carry this force. The placing of coupling bars as the connection to the precast concrete floor is to ensure the continuity of precast floor diaphragm. In this study, in-situ steel fibre grouting was used to fill the connection between the precast concrete slab instead of the conventional method using in-situ concrete and at the same time, the number of coupling bars was also reduced. This study was conducted to determine the horizontal shear force for different arrangement of coupling bars with and without steel fibre. The experimental test using push-off test method was conducted. The results of push-off test for specimens with different arrangement of coupling bars were compared with the control specimen. The steel fibre grouting shows the improvement in term of ultimate strength and ductility of the in-situ grout. Besides, the additional of steel fibre in grout also influence the ultimate horizontal load of the specimen compare with the plain grout. The push-off test shows that the specimen that have only two numbers of coupling bars and with in-situ steel fibre grouting performed better than the control specimen. 2018 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/86951/1/SafiahZalehaAwaludinMFKA2018.pdf Awaludin, Safiah Zaleha (2018) Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre. Masters thesis, Universiti Teknologi Malaysia, Faculty of Civil Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:132583
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Awaludin, Safiah Zaleha
Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre
description In precast concrete slab, the coupling bars and in-situ concrete act as the precast slab panel connection. The design of coupling bars based on Eurocode 2 must be able to resist the horizontal shear force and the U-loop bar must also be design to carry this force. The placing of coupling bars as the connection to the precast concrete floor is to ensure the continuity of precast floor diaphragm. In this study, in-situ steel fibre grouting was used to fill the connection between the precast concrete slab instead of the conventional method using in-situ concrete and at the same time, the number of coupling bars was also reduced. This study was conducted to determine the horizontal shear force for different arrangement of coupling bars with and without steel fibre. The experimental test using push-off test method was conducted. The results of push-off test for specimens with different arrangement of coupling bars were compared with the control specimen. The steel fibre grouting shows the improvement in term of ultimate strength and ductility of the in-situ grout. Besides, the additional of steel fibre in grout also influence the ultimate horizontal load of the specimen compare with the plain grout. The push-off test shows that the specimen that have only two numbers of coupling bars and with in-situ steel fibre grouting performed better than the control specimen.
format Thesis
author Awaludin, Safiah Zaleha
author_facet Awaludin, Safiah Zaleha
author_sort Awaludin, Safiah Zaleha
title Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre
title_short Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre
title_full Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre
title_fullStr Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre
title_full_unstemmed Horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre
title_sort horizontal shear force for different arrangements of coupling bars in precast concrete slab with and without steel fibre
publishDate 2018
url http://eprints.utm.my/id/eprint/86951/1/SafiahZalehaAwaludinMFKA2018.pdf
http://eprints.utm.my/id/eprint/86951/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:132583
_version_ 1683230688469319680
score 13.160551