Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode

Due to the toxicity of mercury, an alternative electrode has to be constructed still having the unique properties of mercury electrode. Thus, mercury meniscus modified silver amalgam electrode (m-AgSAE) was constructed to overcome this problem and to be the suitable replacement commercial mercury el...

Full description

Saved in:
Bibliographic Details
Main Authors: Hakim Wirzal, Mohd. Dzul, Mohd. Yusoff, Abdull Rahim, Qureshi, Munawar Saeed
Format: Article
Published: World Research Association 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/86080/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.86080
record_format eprints
spelling my.utm.860802020-08-30T08:55:59Z http://eprints.utm.my/id/eprint/86080/ Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode Hakim Wirzal, Mohd. Dzul Mohd. Yusoff, Abdull Rahim Qureshi, Munawar Saeed QD Chemistry Due to the toxicity of mercury, an alternative electrode has to be constructed still having the unique properties of mercury electrode. Thus, mercury meniscus modified silver amalgam electrode (m-AgSAE) was constructed to overcome this problem and to be the suitable replacement commercial mercury electrode. The voltammetric behavior of antibiotic drugs (ampicillin and penicillin G) had been studied using m- AgSAE with Ag/AgCl (3M KCl) as the reference and the measurement was conducted in Britton-Robinson buffer (BRB). Differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) techniques were used to conduct these studies. This study was done to observe and study the capability of m-AgSAE properties that can match with commercial mercury electrode. The optimal conditions for ampicillin and penicillin G determination were successfully evaluated in the concentration range of 10 μmol/L to 90 μmol/L. The limits of detection for ampicillin and penicillin G at m- AgSAE were found to be 3.8 μmol/L and 2.5 μmol/L respectively. Using the optimum conditions, the practical application of the newly developed method has been verified on the determination of ampicillin and penicillin G in spiked samples of drinking and river water. World Research Association 2018-10-01 Article PeerReviewed Hakim Wirzal, Mohd. Dzul and Mohd. Yusoff, Abdull Rahim and Qureshi, Munawar Saeed (2018) Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode. Research Journal of Chemistry and Environment, 22 (10). pp. 34-41. ISSN 0972-0626
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic QD Chemistry
spellingShingle QD Chemistry
Hakim Wirzal, Mohd. Dzul
Mohd. Yusoff, Abdull Rahim
Qureshi, Munawar Saeed
Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode
description Due to the toxicity of mercury, an alternative electrode has to be constructed still having the unique properties of mercury electrode. Thus, mercury meniscus modified silver amalgam electrode (m-AgSAE) was constructed to overcome this problem and to be the suitable replacement commercial mercury electrode. The voltammetric behavior of antibiotic drugs (ampicillin and penicillin G) had been studied using m- AgSAE with Ag/AgCl (3M KCl) as the reference and the measurement was conducted in Britton-Robinson buffer (BRB). Differential pulse voltammetry (DPV) and adsorptive stripping voltammetry (AdSV) techniques were used to conduct these studies. This study was done to observe and study the capability of m-AgSAE properties that can match with commercial mercury electrode. The optimal conditions for ampicillin and penicillin G determination were successfully evaluated in the concentration range of 10 μmol/L to 90 μmol/L. The limits of detection for ampicillin and penicillin G at m- AgSAE were found to be 3.8 μmol/L and 2.5 μmol/L respectively. Using the optimum conditions, the practical application of the newly developed method has been verified on the determination of ampicillin and penicillin G in spiked samples of drinking and river water.
format Article
author Hakim Wirzal, Mohd. Dzul
Mohd. Yusoff, Abdull Rahim
Qureshi, Munawar Saeed
author_facet Hakim Wirzal, Mohd. Dzul
Mohd. Yusoff, Abdull Rahim
Qureshi, Munawar Saeed
author_sort Hakim Wirzal, Mohd. Dzul
title Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode
title_short Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode
title_full Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode
title_fullStr Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode
title_full_unstemmed Voltammetric determination of ampicillin and penicillin G at a mercury meniscus modified silver amalgam electrode
title_sort voltammetric determination of ampicillin and penicillin g at a mercury meniscus modified silver amalgam electrode
publisher World Research Association
publishDate 2018
url http://eprints.utm.my/id/eprint/86080/
_version_ 1677781127634354176
score 13.188404