Non-linear analysis of botlted flush endplate steel beam-to-column connections

In the typical steel building construction, steel connections are playing a crucial part in the construction to connect two different members into a desired length as specified by the architect. In modern building industry, it is a challenge for design engineers to provide simple steel connections t...

Full description

Saved in:
Bibliographic Details
Main Author: Chou, Ka Chun
Format: Thesis
Language:English
Published: 2017
Subjects:
Online Access:http://eprints.utm.my/id/eprint/85788/1/CHouKaChunMFKA2017.pdf
http://eprints.utm.my/id/eprint/85788/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:132385
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.85788
record_format eprints
spelling my.utm.857882020-07-30T07:34:20Z http://eprints.utm.my/id/eprint/85788/ Non-linear analysis of botlted flush endplate steel beam-to-column connections Chou, Ka Chun TA Engineering (General). Civil engineering (General) In the typical steel building construction, steel connections are playing a crucial part in the construction to connect two different members into a desired length as specified by the architect. In modern building industry, it is a challenge for design engineers to provide simple steel connections to aid the construction sequence as most connections required by modern architecture is often complex. It was a common practice for design engineers to design steel connection to behave within the elastic zone of the stress-strain curve. However, this approach does not utilize the capacity of the steel members as well as component within a steel connection as compared to non-linear analysis. Referring to the design standard available locally, design engineers still lack a simple method, formula, or information provided by the codes to carry out preliminary prediction on the effect of the simple steel connection in the non-linear stage. This paper reports the study of non-linear analysis of bolted flush end plate to steel beam-to-column connection by using finite element analysis. Parametric study was carried out to determine the effect of plate thickness and number of bolt on the structural capacity of the connection. Graphs to aid design engineers to assess the nonlinear behaviour of steel connection without a need for detail calculations are plotted from the analysis results. 2017 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/85788/1/CHouKaChunMFKA2017.pdf Chou, Ka Chun (2017) Non-linear analysis of botlted flush endplate steel beam-to-column connections. Masters thesis, Universiti Teknologi Malaysia, Faculty of Engineering - School of Civil Engineering. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:132385
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Chou, Ka Chun
Non-linear analysis of botlted flush endplate steel beam-to-column connections
description In the typical steel building construction, steel connections are playing a crucial part in the construction to connect two different members into a desired length as specified by the architect. In modern building industry, it is a challenge for design engineers to provide simple steel connections to aid the construction sequence as most connections required by modern architecture is often complex. It was a common practice for design engineers to design steel connection to behave within the elastic zone of the stress-strain curve. However, this approach does not utilize the capacity of the steel members as well as component within a steel connection as compared to non-linear analysis. Referring to the design standard available locally, design engineers still lack a simple method, formula, or information provided by the codes to carry out preliminary prediction on the effect of the simple steel connection in the non-linear stage. This paper reports the study of non-linear analysis of bolted flush end plate to steel beam-to-column connection by using finite element analysis. Parametric study was carried out to determine the effect of plate thickness and number of bolt on the structural capacity of the connection. Graphs to aid design engineers to assess the nonlinear behaviour of steel connection without a need for detail calculations are plotted from the analysis results.
format Thesis
author Chou, Ka Chun
author_facet Chou, Ka Chun
author_sort Chou, Ka Chun
title Non-linear analysis of botlted flush endplate steel beam-to-column connections
title_short Non-linear analysis of botlted flush endplate steel beam-to-column connections
title_full Non-linear analysis of botlted flush endplate steel beam-to-column connections
title_fullStr Non-linear analysis of botlted flush endplate steel beam-to-column connections
title_full_unstemmed Non-linear analysis of botlted flush endplate steel beam-to-column connections
title_sort non-linear analysis of botlted flush endplate steel beam-to-column connections
publishDate 2017
url http://eprints.utm.my/id/eprint/85788/1/CHouKaChunMFKA2017.pdf
http://eprints.utm.my/id/eprint/85788/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:132385
_version_ 1674066207987204096
score 13.160551