The optimum location of outrigger in reducing the along-wind and across-wind responses
Outrigger is one of the many tall building structural systems that are used to reduce the building responses to wind. However, it is not known where the outrigger should be placed so that the responses of the tall building due to wind can be minimized. Thus, 64-story reinforced concrete buildings wi...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Faculty of Civil Engineering, Universiti Teknologi Malaysia
2008
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/8524/1/RoslidaAbdSamat2008_TheOptimumLocationofOuttrigger.pdf http://eprints.utm.my/id/eprint/8524/ http://web.utm.my/ipasa/index.php?option=content&task=view&id=734&Itemid |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
my.utm.8524 |
---|---|
record_format |
eprints |
spelling |
my.utm.85242010-08-18T02:22:29Z http://eprints.utm.my/id/eprint/8524/ The optimum location of outrigger in reducing the along-wind and across-wind responses Abd. Samal, Roslinda Mohd. Ali, Nasty Marsono , Abdul Kadir TA Engineering (General). Civil engineering (General) Outrigger is one of the many tall building structural systems that are used to reduce the building responses to wind. However, it is not known where the outrigger should be placed so that the responses of the tall building due to wind can be minimized. Thus, 64-story reinforced concrete buildings with the ratio of height to the breadth of 6:1 are studied in order to determine the optimum location to construct the outriggers to minimize the along-wind and across-wind responses. Buildings with different location of outriggers are analysed by a structural analysis software in order to determine the natural frequencies and eigenvectors in the along-wind and across-wind direction. The along-wind responses are determined by employing the procedures from the ASCE 7-02 while the across-wind responses of the buildings are calculated based on the procedures and wind tunnel data available in a data base of aerodynamic load. The database is comprised of high-frequency base balance measurements on a host of isolated tall buildings models. Results from the analysis shows that the optimum location to construct the outriggers is between one third to two third of the height of the building Faculty of Civil Engineering, Universiti Teknologi Malaysia 2008 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/8524/1/RoslidaAbdSamat2008_TheOptimumLocationofOuttrigger.pdf Abd. Samal, Roslinda and Mohd. Ali, Nasty and Marsono , Abdul Kadir (2008) The optimum location of outrigger in reducing the along-wind and across-wind responses. Malaysian Journal of Civil Engineering, 20 (2). pp. 223-241. ISSN 1823-7843 http://web.utm.my/ipasa/index.php?option=content&task=view&id=734&Itemid |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Abd. Samal, Roslinda Mohd. Ali, Nasty Marsono , Abdul Kadir The optimum location of outrigger in reducing the along-wind and across-wind responses |
description |
Outrigger is one of the many tall building structural systems that are used to reduce the building responses to wind. However, it is not known where the outrigger should be placed so that the responses of the tall building due to wind can be minimized. Thus, 64-story reinforced concrete buildings with the ratio of height to the breadth of 6:1 are studied in order to determine the optimum location to construct the outriggers to minimize the along-wind and across-wind responses. Buildings with different location of outriggers are analysed by a structural analysis software in order to determine the natural frequencies and eigenvectors in the along-wind and across-wind direction. The along-wind responses are determined by employing the procedures from the ASCE 7-02 while the across-wind responses of the buildings are calculated based on the procedures and wind tunnel data available in a data base of aerodynamic load. The database is comprised of high-frequency base balance measurements on a host of isolated tall buildings models. Results from the analysis shows that the optimum location to construct the outriggers is between one third to two third of the height of the building |
format |
Article |
author |
Abd. Samal, Roslinda Mohd. Ali, Nasty Marsono , Abdul Kadir |
author_facet |
Abd. Samal, Roslinda Mohd. Ali, Nasty Marsono , Abdul Kadir |
author_sort |
Abd. Samal, Roslinda |
title |
The optimum location of outrigger in reducing the along-wind and across-wind responses
|
title_short |
The optimum location of outrigger in reducing the along-wind and across-wind responses
|
title_full |
The optimum location of outrigger in reducing the along-wind and across-wind responses
|
title_fullStr |
The optimum location of outrigger in reducing the along-wind and across-wind responses
|
title_full_unstemmed |
The optimum location of outrigger in reducing the along-wind and across-wind responses
|
title_sort |
optimum location of outrigger in reducing the along-wind and across-wind responses |
publisher |
Faculty of Civil Engineering, Universiti Teknologi Malaysia |
publishDate |
2008 |
url |
http://eprints.utm.my/id/eprint/8524/1/RoslidaAbdSamat2008_TheOptimumLocationofOuttrigger.pdf http://eprints.utm.my/id/eprint/8524/ http://web.utm.my/ipasa/index.php?option=content&task=view&id=734&Itemid |
_version_ |
1643645008860938240 |
score |
13.211869 |