Tissue differentiation by refractive index using fiber optic displacement sensor

The optical properties can differentiate biological tissues. Refractive index (RI) is one of the optical parameters that can be used for the said purpose. Many different methods of measuring the refractive index of tissue have been found but involve complicated procedure and setup. The proposed way...

Full description

Saved in:
Bibliographic Details
Main Authors: Al-Ashwal, Rania, Sazali, Amirul Ridhwan, Lo, Alex Zhen Kai, Ab. Rashid, Amir Mustakim, Mohamad Afandi, Mohamad Hafiz, Mohd. Najib, Muhammad Syafiq, Fadzil, Nurul Afiqah, Mohamed Amin, Syakirah
Format: Article
Language:English
Published: Science Publishing Corporation Inc. 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/85181/1/RaniaAlAshwal2018_TissueDifferentiationbyRefractiveIndexusingFiber.pdf
http://eprints.utm.my/id/eprint/85181/
https://www.sciencepubco.com/index.php/ijet/article/view/22138
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.85181
record_format eprints
spelling my.utm.851812020-03-04T01:31:03Z http://eprints.utm.my/id/eprint/85181/ Tissue differentiation by refractive index using fiber optic displacement sensor Al-Ashwal, Rania Sazali, Amirul Ridhwan Lo, Alex Zhen Kai Ab. Rashid, Amir Mustakim Mohamad Afandi, Mohamad Hafiz Mohd. Najib, Muhammad Syafiq Fadzil, Nurul Afiqah Mohamed Amin, Syakirah QH301 Biology TA Engineering (General). Civil engineering (General) The optical properties can differentiate biological tissues. Refractive index (RI) is one of the optical parameters that can be used for the said purpose. Many different methods of measuring the refractive index of tissue have been found but involve complicated procedure and setup. The proposed way of measuring the refractive index of fabric using fibre optic displacement sensor does not include difficult steps. The installation has the highest measurement at 4 mm displacement between the fibre probe and the tissue sample. Sensitivity achieved when tested with three different solutions was 82.74 nW/RIU at the maximum movement. The installation can determine the refractive index of skin, muscle and fat tissue of porcine sample with a difference of 4.3%, 7.4% and 3.9% respectively using the standard RI of each tissue. The proposed method shows promising results and possible application of simple non-contact refractive index measurement of biological tissue. Science Publishing Corporation Inc. 2018 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/85181/1/RaniaAlAshwal2018_TissueDifferentiationbyRefractiveIndexusingFiber.pdf Al-Ashwal, Rania and Sazali, Amirul Ridhwan and Lo, Alex Zhen Kai and Ab. Rashid, Amir Mustakim and Mohamad Afandi, Mohamad Hafiz and Mohd. Najib, Muhammad Syafiq and Fadzil, Nurul Afiqah and Mohamed Amin, Syakirah (2018) Tissue differentiation by refractive index using fiber optic displacement sensor. International Journal of Engineering & Technology, 7 (4.26). pp. 60-62. ISSN 2227-524X https://www.sciencepubco.com/index.php/ijet/article/view/22138
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic QH301 Biology
TA Engineering (General). Civil engineering (General)
spellingShingle QH301 Biology
TA Engineering (General). Civil engineering (General)
Al-Ashwal, Rania
Sazali, Amirul Ridhwan
Lo, Alex Zhen Kai
Ab. Rashid, Amir Mustakim
Mohamad Afandi, Mohamad Hafiz
Mohd. Najib, Muhammad Syafiq
Fadzil, Nurul Afiqah
Mohamed Amin, Syakirah
Tissue differentiation by refractive index using fiber optic displacement sensor
description The optical properties can differentiate biological tissues. Refractive index (RI) is one of the optical parameters that can be used for the said purpose. Many different methods of measuring the refractive index of tissue have been found but involve complicated procedure and setup. The proposed way of measuring the refractive index of fabric using fibre optic displacement sensor does not include difficult steps. The installation has the highest measurement at 4 mm displacement between the fibre probe and the tissue sample. Sensitivity achieved when tested with three different solutions was 82.74 nW/RIU at the maximum movement. The installation can determine the refractive index of skin, muscle and fat tissue of porcine sample with a difference of 4.3%, 7.4% and 3.9% respectively using the standard RI of each tissue. The proposed method shows promising results and possible application of simple non-contact refractive index measurement of biological tissue.
format Article
author Al-Ashwal, Rania
Sazali, Amirul Ridhwan
Lo, Alex Zhen Kai
Ab. Rashid, Amir Mustakim
Mohamad Afandi, Mohamad Hafiz
Mohd. Najib, Muhammad Syafiq
Fadzil, Nurul Afiqah
Mohamed Amin, Syakirah
author_facet Al-Ashwal, Rania
Sazali, Amirul Ridhwan
Lo, Alex Zhen Kai
Ab. Rashid, Amir Mustakim
Mohamad Afandi, Mohamad Hafiz
Mohd. Najib, Muhammad Syafiq
Fadzil, Nurul Afiqah
Mohamed Amin, Syakirah
author_sort Al-Ashwal, Rania
title Tissue differentiation by refractive index using fiber optic displacement sensor
title_short Tissue differentiation by refractive index using fiber optic displacement sensor
title_full Tissue differentiation by refractive index using fiber optic displacement sensor
title_fullStr Tissue differentiation by refractive index using fiber optic displacement sensor
title_full_unstemmed Tissue differentiation by refractive index using fiber optic displacement sensor
title_sort tissue differentiation by refractive index using fiber optic displacement sensor
publisher Science Publishing Corporation Inc.
publishDate 2018
url http://eprints.utm.my/id/eprint/85181/1/RaniaAlAshwal2018_TissueDifferentiationbyRefractiveIndexusingFiber.pdf
http://eprints.utm.my/id/eprint/85181/
https://www.sciencepubco.com/index.php/ijet/article/view/22138
_version_ 1662754362907164672
score 13.160551