Optimisation of wastewater volume of single chamber biological cathodic protection system

In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and opt...

Full description

Saved in:
Bibliographic Details
Main Authors: Wan Ali, Wan Nor Azita, Azman, Anis Fitri Afira, Samsudin, Mohd. Dinie Muhaimin, Mohd. Zaini Makhtar, Muaz, Ibrahim, Norazana, Md. Kasmani, Rafiziana
Format: Article
Published: AIDIC Servizi S.r.l. 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/84379/
https://doi.org/0.3303/CET1863070
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.84379
record_format eprints
spelling my.utm.843792019-12-28T01:55:37Z http://eprints.utm.my/id/eprint/84379/ Optimisation of wastewater volume of single chamber biological cathodic protection system Wan Ali, Wan Nor Azita Azman, Anis Fitri Afira Samsudin, Mohd. Dinie Muhaimin Mohd. Zaini Makhtar, Muaz Ibrahim, Norazana Md. Kasmani, Rafiziana TP Chemical technology In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and optimise the effect of volume ratio of wastewater to the sand on biological CP performance by using Taguchi method. The maximum performance of biological CP in this study was obtained at the largest volume ratio. The orthogonal array and the signal-to-noise ratio (S/N) were employed to study the effect of volume ratio on performance of biological CP. The CP potential vs. copper sulfate electrode (CSE) was -835 mV. It shows that the corrosion of carbon steel pipe was reduced since the native potential of the carbon steel pipe vs. CSE was -531 mV. AIDIC Servizi S.r.l. 2018 Article PeerReviewed Wan Ali, Wan Nor Azita and Azman, Anis Fitri Afira and Samsudin, Mohd. Dinie Muhaimin and Mohd. Zaini Makhtar, Muaz and Ibrahim, Norazana and Md. Kasmani, Rafiziana (2018) Optimisation of wastewater volume of single chamber biological cathodic protection system. Chemical Engineering Transactions, 63 . pp. 415-420. ISSN 2283-9216 https://doi.org/0.3303/CET1863070
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic TP Chemical technology
spellingShingle TP Chemical technology
Wan Ali, Wan Nor Azita
Azman, Anis Fitri Afira
Samsudin, Mohd. Dinie Muhaimin
Mohd. Zaini Makhtar, Muaz
Ibrahim, Norazana
Md. Kasmani, Rafiziana
Optimisation of wastewater volume of single chamber biological cathodic protection system
description In this study, the concept of Microbial Fuel Cells (MFCs) was applied in the biological cathodic protection (CP) system in order to protect steel pipe. There are various factors affect the performance of the system including the volume of the medium.The purposes of this study were to analyse and optimise the effect of volume ratio of wastewater to the sand on biological CP performance by using Taguchi method. The maximum performance of biological CP in this study was obtained at the largest volume ratio. The orthogonal array and the signal-to-noise ratio (S/N) were employed to study the effect of volume ratio on performance of biological CP. The CP potential vs. copper sulfate electrode (CSE) was -835 mV. It shows that the corrosion of carbon steel pipe was reduced since the native potential of the carbon steel pipe vs. CSE was -531 mV.
format Article
author Wan Ali, Wan Nor Azita
Azman, Anis Fitri Afira
Samsudin, Mohd. Dinie Muhaimin
Mohd. Zaini Makhtar, Muaz
Ibrahim, Norazana
Md. Kasmani, Rafiziana
author_facet Wan Ali, Wan Nor Azita
Azman, Anis Fitri Afira
Samsudin, Mohd. Dinie Muhaimin
Mohd. Zaini Makhtar, Muaz
Ibrahim, Norazana
Md. Kasmani, Rafiziana
author_sort Wan Ali, Wan Nor Azita
title Optimisation of wastewater volume of single chamber biological cathodic protection system
title_short Optimisation of wastewater volume of single chamber biological cathodic protection system
title_full Optimisation of wastewater volume of single chamber biological cathodic protection system
title_fullStr Optimisation of wastewater volume of single chamber biological cathodic protection system
title_full_unstemmed Optimisation of wastewater volume of single chamber biological cathodic protection system
title_sort optimisation of wastewater volume of single chamber biological cathodic protection system
publisher AIDIC Servizi S.r.l.
publishDate 2018
url http://eprints.utm.my/id/eprint/84379/
https://doi.org/0.3303/CET1863070
_version_ 1654960079276867584
score 13.160551