Investigation of pipe shear connectors using push out test

Mechanical shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface in composite beams. Steel pipe as a new shear connector is proposed in this research and its performance to achieve composite strength is investigated. Experimental monotonic push-...

Full description

Saved in:
Bibliographic Details
Main Authors: Nasrollahi, Saeed, Maleki, Shervin, Shariati, Mahdi, Marto, Aminaton, Khorami, Majid
Format: Article
Published: Korea Institute of Science and Technology Information 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/84151/
https://doi.org/10.12989/scs.2018.27.5.537
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.84151
record_format eprints
spelling my.utm.841512019-12-16T03:20:31Z http://eprints.utm.my/id/eprint/84151/ Investigation of pipe shear connectors using push out test Nasrollahi, Saeed Maleki, Shervin Shariati, Mahdi Marto, Aminaton Khorami, Majid T Technology (General) Mechanical shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface in composite beams. Steel pipe as a new shear connector is proposed in this research and its performance to achieve composite strength is investigated. Experimental monotonic push-out tests were carried out for this connector. Then, a nonlinear finite element model of the push-out specimens is developed and verified against test results. Further, the finite element model is used to investigate the effects of pipe thickness, length and diameter on the shear strength of the connectors. The ultimate strengths of these connectors are reported and their respective failure modes are discussed. This paper comprises of the push-out tests of ten specimens on this shear connector in both the vertical and horizontal positions in different reinforced concretes. The results of experimental tests are given as load-deformation plots. It is concluded that the use of these connectors is very effective and economical in the medium shear demand range of 150-350 KN. The dominant failure modes observed were either failure of concrete block (crushing and splitting) or shear failure of pipe connector. It is shown that the horizontal pipe is not as effective as vertical pipe shear connector and is not recommended for practical use. It is shown that pipe connectors are more effective in transferring shear forces than channel and stud connectors. Moreover, based on the parametric study, a formula is presented to predict the pipe shear connectors' capacity. Korea Institute of Science and Technology Information 2018 Article PeerReviewed Nasrollahi, Saeed and Maleki, Shervin and Shariati, Mahdi and Marto, Aminaton and Khorami, Majid (2018) Investigation of pipe shear connectors using push out test. Steel and Composite Structures, 27 (5). pp. 537-543. ISSN 1229-9367 https://doi.org/10.12989/scs.2018.27.5.537
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
spellingShingle T Technology (General)
Nasrollahi, Saeed
Maleki, Shervin
Shariati, Mahdi
Marto, Aminaton
Khorami, Majid
Investigation of pipe shear connectors using push out test
description Mechanical shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface in composite beams. Steel pipe as a new shear connector is proposed in this research and its performance to achieve composite strength is investigated. Experimental monotonic push-out tests were carried out for this connector. Then, a nonlinear finite element model of the push-out specimens is developed and verified against test results. Further, the finite element model is used to investigate the effects of pipe thickness, length and diameter on the shear strength of the connectors. The ultimate strengths of these connectors are reported and their respective failure modes are discussed. This paper comprises of the push-out tests of ten specimens on this shear connector in both the vertical and horizontal positions in different reinforced concretes. The results of experimental tests are given as load-deformation plots. It is concluded that the use of these connectors is very effective and economical in the medium shear demand range of 150-350 KN. The dominant failure modes observed were either failure of concrete block (crushing and splitting) or shear failure of pipe connector. It is shown that the horizontal pipe is not as effective as vertical pipe shear connector and is not recommended for practical use. It is shown that pipe connectors are more effective in transferring shear forces than channel and stud connectors. Moreover, based on the parametric study, a formula is presented to predict the pipe shear connectors' capacity.
format Article
author Nasrollahi, Saeed
Maleki, Shervin
Shariati, Mahdi
Marto, Aminaton
Khorami, Majid
author_facet Nasrollahi, Saeed
Maleki, Shervin
Shariati, Mahdi
Marto, Aminaton
Khorami, Majid
author_sort Nasrollahi, Saeed
title Investigation of pipe shear connectors using push out test
title_short Investigation of pipe shear connectors using push out test
title_full Investigation of pipe shear connectors using push out test
title_fullStr Investigation of pipe shear connectors using push out test
title_full_unstemmed Investigation of pipe shear connectors using push out test
title_sort investigation of pipe shear connectors using push out test
publisher Korea Institute of Science and Technology Information
publishDate 2018
url http://eprints.utm.my/id/eprint/84151/
https://doi.org/10.12989/scs.2018.27.5.537
_version_ 1654960047911862272