Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur

Construction by nature is inherently dangerous, with a high degree of hazard and risk. Serious fire has occurred in building under construction, which will not delay their completion dates and loss of life, but also result in serious monetary losses. The objectives of this paper are to investigate t...

Full description

Saved in:
Bibliographic Details
Main Authors: Ismail, Syuhaida, Wahab, Mohammad Hussaini, Che Amat, Rohayah, Wan Mohd. Rani, Wan Nurul Mardiah, Zakaria, Zaamuddin
Format: Conference or Workshop Item
Published: 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/83263/
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.83263
record_format eprints
spelling my.utm.832632019-10-17T07:02:28Z http://eprints.utm.my/id/eprint/83263/ Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur Ismail, Syuhaida Wahab, Mohammad Hussaini Che Amat, Rohayah Wan Mohd. Rani, Wan Nurul Mardiah Zakaria, Zaamuddin T Technology (General) Construction by nature is inherently dangerous, with a high degree of hazard and risk. Serious fire has occurred in building under construction, which will not delay their completion dates and loss of life, but also result in serious monetary losses. The objectives of this paper are to investigate the causes of fire hazard during the construction phase; assess the risk level arising from the fire hazard during the construction phase; and tpropose safety control measures of fire hazard during the construction phase. Primary data is obtained from the respondents of a mixed use development project in Kuala Lumpur via questionnaire surveys. The data is analysed via Statistical Package for the Social Science (SPSS) and Hazard Identification, Risk Assessment and Risk Control (HIRARC). The findings show that the most important causes of fire hazard of a mixed-use development project are related to workers site activities. Meanwhile, HIRARC identifies that fire hazard from hot works and use electrical tools are the most important risks. Lastly, safety control measures were proposed to control the identified fire hazard by improving the operating procedure of hot works and use of electrical tools as well as implementing good housekeeping practices and inspection at the workplace 2018 Conference or Workshop Item PeerReviewed Ismail, Syuhaida and Wahab, Mohammad Hussaini and Che Amat, Rohayah and Wan Mohd. Rani, Wan Nurul Mardiah and Zakaria, Zaamuddin (2018) Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur. In: 2nd International Conference on Architecture and Civil Engineering (ICACE 2018).
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic T Technology (General)
spellingShingle T Technology (General)
Ismail, Syuhaida
Wahab, Mohammad Hussaini
Che Amat, Rohayah
Wan Mohd. Rani, Wan Nurul Mardiah
Zakaria, Zaamuddin
Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur
description Construction by nature is inherently dangerous, with a high degree of hazard and risk. Serious fire has occurred in building under construction, which will not delay their completion dates and loss of life, but also result in serious monetary losses. The objectives of this paper are to investigate the causes of fire hazard during the construction phase; assess the risk level arising from the fire hazard during the construction phase; and tpropose safety control measures of fire hazard during the construction phase. Primary data is obtained from the respondents of a mixed use development project in Kuala Lumpur via questionnaire surveys. The data is analysed via Statistical Package for the Social Science (SPSS) and Hazard Identification, Risk Assessment and Risk Control (HIRARC). The findings show that the most important causes of fire hazard of a mixed-use development project are related to workers site activities. Meanwhile, HIRARC identifies that fire hazard from hot works and use electrical tools are the most important risks. Lastly, safety control measures were proposed to control the identified fire hazard by improving the operating procedure of hot works and use of electrical tools as well as implementing good housekeeping practices and inspection at the workplace
format Conference or Workshop Item
author Ismail, Syuhaida
Wahab, Mohammad Hussaini
Che Amat, Rohayah
Wan Mohd. Rani, Wan Nurul Mardiah
Zakaria, Zaamuddin
author_facet Ismail, Syuhaida
Wahab, Mohammad Hussaini
Che Amat, Rohayah
Wan Mohd. Rani, Wan Nurul Mardiah
Zakaria, Zaamuddin
author_sort Ismail, Syuhaida
title Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur
title_short Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur
title_full Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur
title_fullStr Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur
title_full_unstemmed Fire hazard assessment during construction phase: case study of a mixed-use development project in Kuala Lumpur
title_sort fire hazard assessment during construction phase: case study of a mixed-use development project in kuala lumpur
publishDate 2018
url http://eprints.utm.my/id/eprint/83263/
_version_ 1651866679190224896
score 13.211869