A numerical study of air flow in a coaxial pipe

A simulation study of a cold-flow in coaxial pipes was carried out with varying drivepipe diameter and entrance displacement (?L). The current work has studied the effect of the temperature of the entrance flow inlet with variation of ?L to the entrained flow characteristics. To predict these flo...

Full description

Saved in:
Bibliographic Details
Main Authors: Adi, Surjosatyo, Ani, Farid Nasir
Format: Article
Language:English
Published: Penerbit UTM Press 2001
Subjects:
Online Access:http://eprints.utm.my/id/eprint/827/1/JT34A1.pdf
http://eprints.utm.my/id/eprint/827/
http://www.penerbit.utm.my/onlinejournal/34/A/JT34A1.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A simulation study of a cold-flow in coaxial pipes was carried out with varying drivepipe diameter and entrance displacement (?L). The current work has studied the effect of the temperature of the entrance flow inlet with variation of ?L to the entrained flow characteristics. To predict these flow characteristics, a numerical method was employed by the differencing scheme for integrating the continuity equation and energy equation. A k-? turbulent model was used to simulate the turbulent transport quantities. The 2-D flow pattern was created as the result of using Fluent version 4.4 CFD modeling package. Results showed that increasing the air entrained temperature until 600 K would decrease the airflow rate. It was found that the diameter ratio of 2.81 has the highest entrained flow rate