Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study

This study is based on one of the corrosion control which is cathodic protection on impressed current cathodic protection (ICCP). The purpose of this study is to investigate the effect of pH and moisture content on corrosion current density of ICCP for carbon steel pipe. Several factors could affect...

Full description

Saved in:
Bibliographic Details
Main Authors: Baharuddin, Dzulikram, Samsudin, Mohd. Dinie Muhaimin
Format: Article
Language:English
Published: Zibeline International Publishing 2018
Subjects:
Online Access:http://eprints.utm.my/id/eprint/82048/1/DzulikramBaharuddin2018_EffectofPHandMoistureContentonCurrentDensity.pdf
http://eprints.utm.my/id/eprint/82048/
http://dx.doi.org/10.26480/ees.02.2018.15.19
Tags: Add Tag
No Tags, Be the first to tag this record!
id my.utm.82048
record_format eprints
spelling my.utm.820482019-10-22T00:04:35Z http://eprints.utm.my/id/eprint/82048/ Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study Baharuddin, Dzulikram Samsudin, Mohd. Dinie Muhaimin TP Chemical technology This study is based on one of the corrosion control which is cathodic protection on impressed current cathodic protection (ICCP). The purpose of this study is to investigate the effect of pH and moisture content on corrosion current density of ICCP for carbon steel pipe. Several factors could affect the corrosion current density including pH and moisture content of the soil. This study will be conducted by investigate the effect of these variables on current density using one-factor-at-a-time (OFAT) method and response surface methodology (RSM) via face centered central composite design (FCCCD) using Design-Expert 6.0.6 software. The results of this study is analyses via analysis of variance (ANOVA) and used to illustrate the interactions between variables on current density by graphical, equation and modeling which are response surface plots (three-dimensional plots-3D) and contour plots (two-dimensional plots-2D). Zibeline International Publishing 2018 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/82048/1/DzulikramBaharuddin2018_EffectofPHandMoistureContentonCurrentDensity.pdf Baharuddin, Dzulikram and Samsudin, Mohd. Dinie Muhaimin (2018) Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study. Environment & Ecosystem Science (EES), 2 (2). pp. 15-19. ISSN 2521-0882 http://dx.doi.org/10.26480/ees.02.2018.15.19 DOI:10.26480/ees.02.2018.15.19
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TP Chemical technology
spellingShingle TP Chemical technology
Baharuddin, Dzulikram
Samsudin, Mohd. Dinie Muhaimin
Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study
description This study is based on one of the corrosion control which is cathodic protection on impressed current cathodic protection (ICCP). The purpose of this study is to investigate the effect of pH and moisture content on corrosion current density of ICCP for carbon steel pipe. Several factors could affect the corrosion current density including pH and moisture content of the soil. This study will be conducted by investigate the effect of these variables on current density using one-factor-at-a-time (OFAT) method and response surface methodology (RSM) via face centered central composite design (FCCCD) using Design-Expert 6.0.6 software. The results of this study is analyses via analysis of variance (ANOVA) and used to illustrate the interactions between variables on current density by graphical, equation and modeling which are response surface plots (three-dimensional plots-3D) and contour plots (two-dimensional plots-2D).
format Article
author Baharuddin, Dzulikram
Samsudin, Mohd. Dinie Muhaimin
author_facet Baharuddin, Dzulikram
Samsudin, Mohd. Dinie Muhaimin
author_sort Baharuddin, Dzulikram
title Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study
title_short Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study
title_full Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study
title_fullStr Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study
title_full_unstemmed Effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study
title_sort effect of ph and moisture content on current density of impressed current cathodic protection : response surface methodology study
publisher Zibeline International Publishing
publishDate 2018
url http://eprints.utm.my/id/eprint/82048/1/DzulikramBaharuddin2018_EffectofPHandMoistureContentonCurrentDensity.pdf
http://eprints.utm.my/id/eprint/82048/
http://dx.doi.org/10.26480/ees.02.2018.15.19
_version_ 1651866599321239552
score 13.211869